Photon dose calculation analysis of a varian treatment planning system algorithm on a siemens linear accelerator in inhomogeneous media

被引:0
|
作者
Finlay, J. [1 ]
Mesina, C. [1 ]
机构
[1] Univ Penn, Philadelphia, PA 19104 USA
关键词
D O I
10.1118/1.2761009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To analyze the accuracy of photon dose calculations in inhomogeneous media using the analytical anisotropic algorithm (AAA) and pencil beam convolution (PBC) implemented in Varian Medical Systems' Eclipse treatment planning system with Siemens linear accelerators. Method and Materials: Using a 0.125 cm3 ionization chamber in a 3‐layer phantom with cork between water‐equivalent layers, we measured absolute depth doses (DD) for 6 and 15 MV, and 3, 5, 10, and 20 cm square fields. To assess lateral disequilibrium modeling, we irradiated another phantom in which the middle cork layer extended laterally only 2.5 cm beyond the central axis, the remainder of the layer being plastic with 10 and 20 cm square fields. Dose profiles were measured using EDR2 film placed at three depths and with a diode detector array placed in the bottom layer. Calculations were performed using AAA and PBC with inhomogeneity correction in Eclipse. Results: For both 6 and 15 MV, the DD calculated by AAA and PBC agreed with measurement within 2% and 3%, respectively proximal to the inhomogeneity beyond the buildup region. Within the inhomogeneity, the agreement was better than 6% for large fields, however, both algorithms overestimated the dose by up to 20% (AAA) or 55% (PBC) for the 3‐cm 6MV field. Distal to the inhomogeneity, AAA modeled the shape of the buildup more accurately than PBC. Lateral profiles indicated that the shape of the penumbra in the inhomogeneous region and the perturbation at the vertical interface predicted by AAA agreed with film and diode array measurements better than PBC. Conclusion: AAA offered an overall improvement over PBC in inhomogeneous media, particularly for small fields and in interface and buildup regions. The overestimate of dose within the inhomogeneity for small fields motivates further investigation, particularly if AAA is used for IMRT calculations in lung. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2481 / 2481
页数:1
相关论文
共 50 条
  • [21] VMAT with a Synergy linear accelerator and the Eclipse treatment planning system
    Glessmer, S.
    Maass, T.
    Paque, R.
    Fehlauer, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 106 - 106
  • [22] Commissioning a superposition dose calculation model for 6 MV photon beams on a radiotherapy treatment planning system
    Ambolt, P.
    Bowden, J.
    Cooper, M.
    Henry, A.
    McCormack, S.
    Morgan, A.
    Patrick, S.
    Thompson, R.
    Thwaites, D.
    CLINICAL ONCOLOGY, 2007, 19 (03) : S40 - S40
  • [23] Dosemetric Uncertainties in the Electron Monte Carlo Dose Calculation Algorithm in the Eclipse Treatment Planning System
    Kendall, E.
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2018, 45 (06) : E249 - E250
  • [24] EVALUATION OF DOSE CALCULATION ALGORITHM IN THE PEACOCK TREATMENT PLANNING SYSTEM FOR MULTILEAF INTENSITY MODULATION COLLIMATOR
    WU, A
    JOHNSON, M
    CHEN, A
    KALNICKI, S
    BLEIER, AR
    KANIA, AA
    RADIOLOGY, 1995, 197 : 189 - 189
  • [25] Accuracy and efficiency of graphics processing unit (GPU) based Acuros XB dose calculation within the Varian Eclipse treatment planning system
    Aland, Trent
    Walsh, Anthony
    Jones, Marl
    Piccini, Angelina
    Devlin, Aimee
    MEDICAL DOSIMETRY, 2019, 44 (03) : 219 - 225
  • [26] Analysis of accuracy in dose and position in calculations of a treatment planning system for blocked photon fields
    vantVeld, AA
    RADIOTHERAPY AND ONCOLOGY, 1997, 45 (03) : 245 - 251
  • [27] PHOTON-BEAM MODELING AND DOSE CALCULATION ALGORITHMS IN TREATMENT PLANNING COMPUTERS
    PURDY, JA
    MEDICAL PHYSICS, 1982, 9 (04) : 645 - 645
  • [28] A virtual-accelerator-based verification of a Monte Carlo dose calculation algorithm for electron beam treatment planning in homogeneous phantoms
    Wieslander, E
    Knöös, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06): : 1533 - 1544
  • [29] Commissioning of Monaco Treatment Planning System On An Elekta VersaHD Linear Accelerator
    Narayanasamy, G.
    Bosse, C.
    Saenz, D.
    Cruz, W.
    Mavroidis, P.
    Papanikolaou, N.
    Stathakis, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3376 - 3376
  • [30] Commercial IMRT treatment-planning dose-calculation algorithm
    Low, DA
    Mutic, S
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (04): : 933 - 937