Pressure/colorimetric dual-readout immunochromatographic test strip for point-of-care testing of aflatoxin B1

被引:28
|
作者
Jiang, Shan [1 ]
Zhang, Lvxia [1 ]
Li, Jizhou [1 ]
Ouyang, Hui [1 ]
Fu, Zhifeng [1 ]
机构
[1] Southwest Univ, Coll Pharmaceut Sci, Key Lab Luminescence Anal & Mol Sensing, Minist Educ, Chongqing 400716, Peoples R China
基金
中国国家自然科学基金;
关键词
Immunochromotographic test strip; Dual-readout probe; Point-of-care testing; Pressure-based assay; Colorimetry; GOLD NANOPARTICLES; CHROMATOGRAPHY; NANOFIBERS; SIGNAL; ASSAY;
D O I
10.1016/j.talanta.2021.122203
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Immunochromatographic test strip (ITS) for point-of-care testing (POCT) has attracted prominent attention due to the advantages including rapid response, low cost and good portability. Here, we developed a sensitive ITS for detecting aflatoxin B-1 (AFB(1)) by using dendritic platinum nanoparticles (DPNs) as novel pressure/colorimetric dual-readout probes. DPNs-labeled antibody of AFB(1) were used as the signal tracer of the immunochromatographic process. After 10-min competitive immunoreaction, black color appeared on the test line of ITS due to the accumulation of DPNs, which was observed visually as a colorimetric readout for qualitation purpose. Furthermore, DPNs with peroxidase-like activity caused decomposition of hydrogen peroxide aqueous solution to produce pressure change signal in vials, which was detected by a hand-held pressure meter for quantitation purpose. With the pressure readout mode, the detection range was 0.05-10 ng mL(-1), and the detection limit was 0.03 ng mL(-1) (S/N = 3) for AFB(1). The proposed ITS was successfully utilized for detecting AFB(1) in herbal medicine samples, and the acceptable recoveries of 93.77-114.09% indicated the reliability for real sample detection. It provides a new avenue for POCT with great application potential in various area including drug and food quality control, pollutants monitoring as well as medical diagnosis.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Immunochromatographic Strip Based on Tetrahedral DNA Immunoprobe for the Detection of Aflatoxin B1 in Rice Bran Oil
    Xu, Lin
    Qu, Wenli
    Hao, Xiaotong
    Fang, Min
    Yang, Qing
    Li, Yuzhi
    Gong, Zhiyong
    Li, Peiwu
    FOODS, 2024, 13 (15)
  • [22] UiOL@AIEgens-assisted lateral flow immunosensor for the ultrasensitive dual-modal point-of-care detection of aflatoxin B1
    Wu, Wenjuan
    Li, Ying
    Song, Pengyue
    Xu, Qingbin
    Lei, Doudou
    Wang, Jiabo
    Fu, Bin
    Kong, Weijun
    JOURNAL OF HAZARDOUS MATERIALS, 2024, 465
  • [23] Oxygen-induced dual-signal point-of-care testing aptasensor for aflatoxin B1 detection using platinum nanoparticle catalysis in visual fluorometry and gravimetry
    Luo, Fang
    Zhan, Linxiu
    Deng, Ye
    Qiao, Kun
    Pan, Nan
    Weng, Zuquan
    Lin, Cuiying
    Qiu, Bin
    Lin, Zhenyu
    ANALYTICA CHIMICA ACTA, 2023, 1273
  • [24] Intelligent Electrochemical Point-of-Care Test Method with Interface Control Based on DNA Pyramids: Aflatoxin B1 Detection in Food and the Environment
    Wu, Wenqin
    Bai, Yizhen
    Zhao, Tiantian
    Liang, Meijuan
    Hu, Xiaofeng
    Wang, Du
    Tang, Xiaoqian
    Yu, Li
    Zhang, Qi
    Li, Peiwu
    Zhang, Zhaowei
    FOODS, 2023, 12 (24)
  • [25] Rapid simultaneous detection of fumonisin B1 and deoxynivalenol in grain by immunochromatographic test strip
    Huang, Xi
    Huang, Xinyu
    Xie, Jianhua
    Li, Xiujiang
    Huang, Zhibing
    ANALYTICAL BIOCHEMISTRY, 2020, 606
  • [26] An immunochromatographic test for measurement of alanine aminotransferase 1 (ALT1) at point-of-care
    Anderson, D. A.
    Garcia, M.
    Van, H.
    Li, F.
    Zhang, Z.
    Zhu, J.
    Feng, Y.
    Hellard, M.
    Doyle, J.
    Li, J.
    JOURNAL OF VIRAL HEPATITIS, 2018, 25 : 13 - 13
  • [27] Determination of aflatoxin B1 in rice, barley, and feed by non-instrumental immunochromatographic strip-test and high sensitive ELISA
    Shim, Won-Bo
    Kim, Jung-Sook
    Kim, Ji-Young
    Choi, Jin-Gil
    Je, Jung-Hyun
    Kuzmina, Nina Sergeevna
    Eremin, Sergei Alexandrovich
    Chung, Duck-Hwa
    FOOD SCIENCE AND BIOTECHNOLOGY, 2008, 17 (03) : 623 - 630
  • [28] Aptasensor-based assay for dual-readout determination of aflatoxin B1 in corn and wheat via an electrostatic force-mediated FRET strategy
    Xiong, Jincheng
    He, Shuang
    Qin, Linqian
    Zhang, Shuai
    Shan, Wenchong
    Jiang, Haiyang
    MICROCHIMICA ACTA, 2023, 190 (02)
  • [29] Rapid and sensitive point-of-care PTS-CRISPR assay for food safety monitoring of aflatoxin B1
    Deng, Ziqiang
    Zhou, Jin
    Wang, Chaoqun
    Hu, Jianyu
    Liu, Rui
    Lv, Yi
    CHEMICAL COMMUNICATIONS, 2023, 59 (80) : 12011 - 12014
  • [30] Construction of Down-conversion Fluorescence-Aptamer Immunochromatographic Strip for Rapid Detection of Aflatoxin B1
    Wang Z.
    Li L.
    Li D.
    Ai C.
    Ren L.
    Sun B.
    Shipin Kexue/Food Science, 2021, 42 (12): : 295 - 301