Statistical analysis of I-125 prostate brachytherapy

被引:0
|
作者
Jang, S.
Pyakuryal, A.
Sathiaseelan, V.
Luo, J.
Kalapurakal, J.
机构
[1] Northwestern Univ, Chicago, IL 60611 USA
[2] Northwestern Mem Hosp, Chicago, IL USA
关键词
D O I
10.1118/1.2761110
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Permanent Interstitial brachytherapy with I‐125 seeds has been utilized for the treatment of early stage prostate cancer and has provided low risk of complications. The purpose of this study was to analyze the preplan and post‐implant dosimetry data statistically for the I‐125 prostate brachytherapy in order to confirm the accuracy and consistency of the seed implant techniques. Method and Materials: Preplan and post‐implant dosimetry were performed for 39 patients in I‐125 prostate brachytherapy during last three years at Northwestern Memorial Hospital (NMH). The prostate volumes were measured using an ultrasound (US) system and the prostate contours with margins were applied for preplans. CT images were acquired within 3 days of the implant day for post‐implant dosimetry. Activities between 0.31 and 0.34 mCi per seed were used for the prescription dose of 144 Gy. The relationships between the US volumes and the numbers of seeds and needles were analyzed. The V(100) and D(90) were obtained in the post‐implant dosimetry. Results: The US volume ranged from 32 cm3 to 65 cm3 (n=39). The mean numbers of seeds and needles used were 95.3, 109.0, 116.1, 130.2 and 32.0, 31.5, 32.6, 35.8 for the US volume groups of 30–39 (n=4), 40–49 (n=17), 50–59 (n=13), 60–65 cm3 (n=5), respectively. The mean V(100) and D(90) were 91.9% of the prostate volume and 105.7% of the prescription dose, respectively. Conclusion: The prostate volume group of 40–49 cm3 (n=17) included the greatest number of patients in this study. The numbers of seeds has increased linearly as the US volume increased. The numbers of needles used were relatively consistent over the different volume groups. We demonstrated the accuracy and consistency of the I‐125 prostate brachytherapy with the modern computer‐based dosimetry, ultrasound system, and template‐based transperineal implant techniques. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2490 / 2490
页数:1
相关论文
共 50 条
  • [31] The influence of hormonal therapy on quality of life in I-125 prostate brachytherapy patients
    Paffen, M. L. J. E.
    Mols, F.
    Stijns, P. E. F.
    Hendrikx, A. J. M.
    JOURNAL OF ENDOUROLOGY, 2007, 21 : A215 - A216
  • [32] Patient-Specific Monte Carlo Dosimetry for I-125 Prostate Brachytherapy
    Miksys, N.
    Enger, S.
    Xu, C.
    Vigneault, E.
    Beaulieu, L.
    Thomson, R. M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [33] Quality assurance of I-125 seeds for prostate brachytherapy using an imaging plate
    Furutani, Shunsuke
    Saze, Takuya
    Ikushima, Hitoshi
    Oita, Masataka
    Ozaki, Kyousuke
    Kishida, Yoshlomi
    Takegawa, Yoshihiro
    Nishitani, Hiromu
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (02): : 603 - 609
  • [34] Effect of stranded and loose seeds in relation to prostate edema in permanent I-125 prostate brachytherapy
    Beiki-Ardakani, A.
    Crook, J.
    Borg, J.
    Elantholiparameswaran, S.
    Yeung, I.
    Landon, A.
    MEDICAL PHYSICS, 2007, 34 (06) : 2446 - 2446
  • [35] I-125 LDR Brachytherapy in Patients with Low-risk Prostate Cancer - a retrospective Analysis of Patients
    Fels, F.
    Okonkwo, E.
    Schadt, T.
    Laschke, S.
    Loevey, G.
    Lansing, D.
    Grossmann, J. G.
    Freund, U.
    Steurer, R.
    Momm, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 : S87 - S87
  • [36] OBJECTIVE COMPUTER AIDED ANALYSIS OF TIME TRENDS IN IMPLANTED PROSTATE VOLUMES AFTER I-125 BRACHYTHERAPY
    Westendorp, R.
    Kattevilder, R.
    Minken, A.
    Hoekstra, C.
    Immerzeel, J.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S104 - S104
  • [37] OPTIMIZATION OF I-125 OPHTHALMIC PLAQUE BRACHYTHERAPY
    ASTRAHAN, MA
    LUXTON, G
    JOZSEF, G
    LIGGETT, PE
    PETROVICH, Z
    MEDICAL PHYSICS, 1990, 17 (06) : 1053 - 1057
  • [38] Brachytherapy - High Dose Rate or I-125?
    Hoskin, P. J.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S65 - S66
  • [39] CHOROIDAL MELANOMA TREATMENT WITH I-125 BRACHYTHERAPY
    GARRETSON, BR
    ROBERTSON, DM
    EARLE, JD
    ARCHIVES OF OPHTHALMOLOGY, 1987, 105 (10) : 1394 - 1397
  • [40] Measurement of I-125 Brachytherapy Dose in Lung
    Gayou, O.
    Kim, Y.
    Johnson, M.
    Colonias, A.
    Werts, E. D.
    MEDICAL PHYSICS, 2012, 39 (06) : 3779 - 3779