Statistical analysis of I-125 prostate brachytherapy

被引:0
|
作者
Jang, S.
Pyakuryal, A.
Sathiaseelan, V.
Luo, J.
Kalapurakal, J.
机构
[1] Northwestern Univ, Chicago, IL 60611 USA
[2] Northwestern Mem Hosp, Chicago, IL USA
关键词
D O I
10.1118/1.2761110
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Permanent Interstitial brachytherapy with I‐125 seeds has been utilized for the treatment of early stage prostate cancer and has provided low risk of complications. The purpose of this study was to analyze the preplan and post‐implant dosimetry data statistically for the I‐125 prostate brachytherapy in order to confirm the accuracy and consistency of the seed implant techniques. Method and Materials: Preplan and post‐implant dosimetry were performed for 39 patients in I‐125 prostate brachytherapy during last three years at Northwestern Memorial Hospital (NMH). The prostate volumes were measured using an ultrasound (US) system and the prostate contours with margins were applied for preplans. CT images were acquired within 3 days of the implant day for post‐implant dosimetry. Activities between 0.31 and 0.34 mCi per seed were used for the prescription dose of 144 Gy. The relationships between the US volumes and the numbers of seeds and needles were analyzed. The V(100) and D(90) were obtained in the post‐implant dosimetry. Results: The US volume ranged from 32 cm3 to 65 cm3 (n=39). The mean numbers of seeds and needles used were 95.3, 109.0, 116.1, 130.2 and 32.0, 31.5, 32.6, 35.8 for the US volume groups of 30–39 (n=4), 40–49 (n=17), 50–59 (n=13), 60–65 cm3 (n=5), respectively. The mean V(100) and D(90) were 91.9% of the prostate volume and 105.7% of the prescription dose, respectively. Conclusion: The prostate volume group of 40–49 cm3 (n=17) included the greatest number of patients in this study. The numbers of seeds has increased linearly as the US volume increased. The numbers of needles used were relatively consistent over the different volume groups. We demonstrated the accuracy and consistency of the I‐125 prostate brachytherapy with the modern computer‐based dosimetry, ultrasound system, and template‐based transperineal implant techniques. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2490 / 2490
页数:1
相关论文
共 50 条
  • [21] I-125 BRACHYTHERAPY FOR MALIGNANT GLIOMAS
    DASILVA, VF
    GUTIN, PH
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 1984, 11 (02) : 323 - 324
  • [22] Comprehensive I-125 mutti-seed comparison for prostate brachytherapy: Dosimetry and visibility analysis
    Al-Qaisieh, Bashar
    Smith, David W.
    Brearley, Elizabeth
    Clair, Shaun St.
    Bownes, Peter
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 (02) : 140 - 147
  • [23] PROSTATE LDR BRACHYTHERAPY WHITH PERMANENT I-125 SEEDS IMPLANT: RESULTS OF A RETROSPECTIVE ANALYSIS
    Chiumento, C.
    Montagna, A.
    Castaldo, G.
    Lapadula, L.
    Pedicini, P.
    Imbriani, E.
    Fusco, V
    ANNALS OF ONCOLOGY, 2009, 20
  • [24] Risk factors for rectal bleeding associated with I-125 brachytherapy for prostate cancer
    Harada, Kosaku
    Ishikawa, Hitoshi
    Saito, Yoshitaka
    Nakamoto, Soken
    Kawamura, Hidemasa
    Wakatsuki, Masaru
    Etsunaga, Toru
    Takezawa, Yutaka
    Kobayashi, Mikio
    Nakano, Takashi
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (06) : 923 - 929
  • [25] A biological approach to optimisation of permanent I-125 prostate implants for focal brachytherapy
    Haworth, A.
    Mears, C.
    Betts, J.
    Reynolds, H.
    Williams, S.
    Ebert, M.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S63 - S64
  • [26] Prostate brachytherapy with permanent I-125 seed implants -: first experiences at the KSSG
    Töpfer, M
    Prikler, L
    Seelentag, W
    Ries, G
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 121 - 121
  • [27] Risk group stratification in patients undergoing permanent I-125 prostate brachytherapy
    Kwok, Y
    DiBiase, SJ
    Amin, PP
    Jacobs, SC
    RADIOLOGY, 2001, 221 : 281 - 281
  • [28] High-risk prostate cancer treated with I-125 brachytherapy.
    Stockham, Abigail Lauren
    Reddy, Chandana A.
    Stephans, Kevin L.
    Ciezki, Jay P.
    Tendulkar, Rahul D.
    JOURNAL OF CLINICAL ONCOLOGY, 2012, 30 (05)
  • [29] I-125 isodose patterns as predictors of inadequate prostate brachytherapy dose coverage
    Reed, D
    Wallner, K
    Cho, P
    Ford, E
    Merrick, G
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S123 - S124
  • [30] DOSIMETRIC OPTIONS AND POSSIBILITIES OF PROSTATE LDR BRACHYTHERAPY WITH PERMANENT I-125 IMPLANTS
    Ivanauskas, Andrius
    Aleknavicius, Eduardas
    Burneckis, Arvydas
    Miller, Albert
    MEDICAL PHYSICS IN THE BALTIC STATES, 2011, : 98 - 101