A one-step electrochemiluminescence immunosensor preparation for ultrasensitive detection of carbohydrate antigen 19-9 based on multifunctionalized graphene oxide

被引:51
|
作者
Sha, Yuhong [1 ]
Guo, Zhiyong [1 ]
Chen, Beibei [1 ]
Wang, Sui [1 ]
Ge, Guoping [1 ]
Qiu, Bin [2 ]
Jiang, Xiaohua [3 ]
机构
[1] Ningbo Univ, Fac Mat Sci & Chem Engn, State Key Lab Base Novel Funct Mat & Preparat Sci, Ningbo 315211, Zhejiang, Peoples R China
[2] Fuzhou Univ, Dept Chem, Fujian Prov Key Lab Anal & Detect Food Safety, Minist Educ,Key Lab Anal & Detect Food Safety, Fuzhou 350002, Peoples R China
[3] Shenzhen Polytech, Sch Appl Chem & Biol Technol, Shenzhen 518055, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2015年 / 66卷
关键词
Electrochemiluminescence immunosensor; Carbohydrate antigen 19-9; Multi-functionalized graphene oxide; N-(4-aminobutyl)-N-ethylisoluminol; One-step preparation; TUMOR-MARKERS; ELECTROCHEMICAL IMMUNOASSAY; SIGNAL AMPLIFICATION; GOLD NANOPARTICLES; QUANTUM DOTS; CA19-9; SERUM; CA15-3; FILM; CEA;
D O I
10.1016/j.bios.2014.12.013
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A one-step electrochemiluminescence (ECL) immunosensor for ultrasensitive detection of carbohydrate antigen 19-9 (CA19-9) was developed based on multi-functionalized graphene oxide (GO), which was prepared with N-(4-aminobutyl)-N-ethylisoluminol (ABEI) and CA19-9 antibody (anti-CA19-9) chemically bound to the surface of magnetic GO (nanoFe(3)O(4)@GO). ABEI and anti-CA19-9 acted as the electrochemiluminophore and the capture device for CA19-9 respectively. NanoFe(3)O(4)@GO enabled all the ABEI immobilized molecules electrochemically active due to its good conductivity, and brought multifunctionalized GO attracted on the surface of magnetic glass carbon electrode through magnetism. Thus the ECL immunosensor could be prepared through a one-step process that facilitates ultrasensitive detection of CA19-9. Under optimal conditions, the ECL intensity of the immunosensor decreased proportionally to the logarithmic concentrations of CA19-9 in the range of 0.001-5 U/mL with a detection limit of 0.0005 U/mL. This one-step ECL immunosensor showed good performance in specificity, stability, reproducibility, regeneration and application. It opened a new avenue to apply multi-functionalized bionanomaterials in ECL immunoassay. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:468 / 473
页数:6
相关论文
共 50 条
  • [41] Directly one-step electrochemical synthesis of graphitic carbon nitride/graphene hybrid and its application in ultrasensitive electrochemiluminescence sensing of pentachlorophenol
    Xia, Binyuan
    Yuan, Qiming
    Chu, Mingfu
    Wang, Shaofei
    Gao, Rui
    Yang, Shanli
    Liu, Chengbin
    Luo, Shenglian
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 228 : 565 - 572
  • [42] Amperometric carbohydrate antigen 19-9 immunosensor based on three dimensional ordered macroporous magnetic Au film coupling direct electrochemistry of horseradish peroxidase
    Zhang, Qi
    Chen, Xiaojun
    Tang, Yin
    Ge, Lingna
    Guo, Buhua
    Yao, Cheng
    ANALYTICA CHIMICA ACTA, 2014, 815 : 42 - 50
  • [43] Meta-analysis of the diagnostic performance of serum carbohydrate antigen 19-9 for the detection of gallbladder cancer
    Zhou, Xiaolei
    INTERNATIONAL JOURNAL OF BIOLOGICAL MARKERS, 2022, 37 (01): : 81 - 89
  • [44] An ultrasensitive electrochemical immunosensor for hepatitis C antibodies based on one-step-eletrosynthetized polypyrrole–graphene nanocomposite
    Gilvânia M. Santana
    Anne K. S. Silva
    Marcos V. Foguel
    Rosa F. Dutra
    Journal of Materials Science, 2022, 57 : 5586 - 5595
  • [45] Ultrasensitive one-step rapid detection of ochratoxin A by the folding-based electrochemical aptasensor
    Wu, Jingjing
    Chu, Huaqin
    Mei, Zhanlong
    Deng, Yi
    Xue, Feng
    Zheng, Lei
    Chen, Wei
    ANALYTICA CHIMICA ACTA, 2012, 753 : 27 - 31
  • [46] One-step electrochemical preparation of graphene-based heterostructures for Li storage
    Zhang, Wenyu
    Zeng, Yi
    Xiao, Ni
    Hng, Huey Hoon
    Yan, Qingyu
    JOURNAL OF MATERIALS CHEMISTRY, 2012, 22 (17) : 8455 - 8461
  • [47] One-step grain pretreatment for ochratoxin A detection based on bipolar electrode-electrochemiluminescence biosensor
    Lu, Lixia
    Yuan, Wei
    Xiong, Qiang
    Wang, Minhui
    Liu, Yuanjian
    Cao, Min
    Xiong, Xiaohui
    ANALYTICA CHIMICA ACTA, 2021, 1141 : 83 - 90
  • [48] A colorimetric and ultrasensitive immunosensor for one-step pathogen detection via the combination of nanoparticle-triggered signal amplification and magnetic separation
    Chen, Yiping
    Xie, Mengxia
    RSC ADVANCES, 2015, 5 (122): : 100633 - 100637
  • [49] Ultrasensitive Electrochemiluminescence Detection of MicroRNA via One-Step Introduction of a Target-Triggered Branched Hybridization Chain Reaction Circuit
    Li, Yang
    Huang, Cheng Zhi
    Li, Yuan Fang
    ANALYTICAL CHEMISTRY, 2019, 91 (14) : 9308 - 9314
  • [50] Validity of Carcinoembryonic Antigen and Carbohydrate Antigen 19-9 Measurements in Pancreatic Cyst Fluid with a Serum-Based Immunoassay
    Boot, Christopher S.
    Mahon, Brinder S.
    Bramhall, Simon R.
    Clark, Penelope M.
    CLINICAL CHEMISTRY, 2010, 56 (08) : 1351 - 1352