A one-step electrochemiluminescence immunosensor preparation for ultrasensitive detection of carbohydrate antigen 19-9 based on multifunctionalized graphene oxide

被引:51
|
作者
Sha, Yuhong [1 ]
Guo, Zhiyong [1 ]
Chen, Beibei [1 ]
Wang, Sui [1 ]
Ge, Guoping [1 ]
Qiu, Bin [2 ]
Jiang, Xiaohua [3 ]
机构
[1] Ningbo Univ, Fac Mat Sci & Chem Engn, State Key Lab Base Novel Funct Mat & Preparat Sci, Ningbo 315211, Zhejiang, Peoples R China
[2] Fuzhou Univ, Dept Chem, Fujian Prov Key Lab Anal & Detect Food Safety, Minist Educ,Key Lab Anal & Detect Food Safety, Fuzhou 350002, Peoples R China
[3] Shenzhen Polytech, Sch Appl Chem & Biol Technol, Shenzhen 518055, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2015年 / 66卷
关键词
Electrochemiluminescence immunosensor; Carbohydrate antigen 19-9; Multi-functionalized graphene oxide; N-(4-aminobutyl)-N-ethylisoluminol; One-step preparation; TUMOR-MARKERS; ELECTROCHEMICAL IMMUNOASSAY; SIGNAL AMPLIFICATION; GOLD NANOPARTICLES; QUANTUM DOTS; CA19-9; SERUM; CA15-3; FILM; CEA;
D O I
10.1016/j.bios.2014.12.013
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A one-step electrochemiluminescence (ECL) immunosensor for ultrasensitive detection of carbohydrate antigen 19-9 (CA19-9) was developed based on multi-functionalized graphene oxide (GO), which was prepared with N-(4-aminobutyl)-N-ethylisoluminol (ABEI) and CA19-9 antibody (anti-CA19-9) chemically bound to the surface of magnetic GO (nanoFe(3)O(4)@GO). ABEI and anti-CA19-9 acted as the electrochemiluminophore and the capture device for CA19-9 respectively. NanoFe(3)O(4)@GO enabled all the ABEI immobilized molecules electrochemically active due to its good conductivity, and brought multifunctionalized GO attracted on the surface of magnetic glass carbon electrode through magnetism. Thus the ECL immunosensor could be prepared through a one-step process that facilitates ultrasensitive detection of CA19-9. Under optimal conditions, the ECL intensity of the immunosensor decreased proportionally to the logarithmic concentrations of CA19-9 in the range of 0.001-5 U/mL with a detection limit of 0.0005 U/mL. This one-step ECL immunosensor showed good performance in specificity, stability, reproducibility, regeneration and application. It opened a new avenue to apply multi-functionalized bionanomaterials in ECL immunoassay. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:468 / 473
页数:6
相关论文
共 50 条
  • [31] Detection of pancreatic cancer with normal carbohydrate antigen 19-9 using protein chip technology
    Xiao-Li Jin
    Bin Xu
    Yu-Lian Wu
    World Journal of Gastroenterology, 2014, (40) : 14958 - 14964
  • [32] URINARY CARBOHYDRATE ANTIGEN 19-9 LEVEL AS A NOVEL BIOMARKER FOR EARLY DETECTION OF ACUTE PYELONEPHRITIS
    Ladi-Seyedian, Seyedeh Sanam
    Kameli, Seyedeh Maryam
    Moghtaderi, Mastaneh
    Kajbafzadeh, Abdol-Mohammad
    JOURNAL OF UROLOGY, 2017, 197 (04): : E800 - E800
  • [33] Detection of pancreatic cancer with normal carbohydrate antigen 19-9 using protein chip technology
    Jin, Xiao-Li
    Xu, Bin
    Wu, Yu-Lian
    WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (40) : 14958 - 14964
  • [34] Label-free immunosensor based on a one-step CTAB intercalated graphene nanocomposite for hepatitis C virus detection
    Santana, Gilvania M.
    Silva, Anne K. S.
    Ferreira, Paula A. B.
    Benjamin, Stephen R.
    Trindade, Erika K. G.
    Dutra, Rosa F.
    SENSING AND BIO-SENSING RESEARCH, 2023, 42
  • [35] A label-free electrochemiluminescence immunosensor based on EuPO4 nanowire for the ultrasensitive detection of Prostate specific antigen
    Ma, Hongmin
    Zhou, Jing
    Li, Yan
    Han, Tongqian
    Zhang, Yong
    Hu, Lihua
    Du, Bin
    Wei, Qin
    BIOSENSORS & BIOELECTRONICS, 2016, 80 : 352 - 358
  • [36] Electrochemiluminescence immunosensor based on graphene-CdS quantum dots-agarose composite for the ultrasensitive detection of alpha fetoprotein
    Guo, Zhiyong
    Hao, Tingting
    Duan, Jing
    Wang, Sui
    Wei, Danyi
    TALANTA, 2012, 89 : 27 - 32
  • [37] A novel electrochemiluminescence immunosensor: BiOBr/Bi2WO6 heterojunction for ultrasensitive detection of CA19-9
    Lu, Baoyu
    Gong, Zhengxing
    Luan, Weichao
    Wu, Dan
    Fan, Yingju
    Su, Qingbo
    Fan, Dawei
    Wei, Qin
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 415
  • [38] TPE based electrochemiluminescence for ALP selective rapid one-step detection applied in vitro
    Li, Shaopeng
    Li, Juan
    Geng, Bing
    Yang, Xiaofeng
    Song, Zhiling
    Li, Zengjun
    Ding, Biyan
    Zhang, Jing
    Lin, Weiying
    Yan, Mei
    MICROCHEMICAL JOURNAL, 2021, 164
  • [39] Building An Aptamer/Graphene Oxide FRET Biosensor for One-Step Detection of Bisphenol A
    Zhu, Yingyue
    Cai, Yilin
    Xu, Liguang
    Zheng, Lixue
    Wang, Limei
    Qi, Bin
    Xu, Chuanlai
    ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (14) : 7492 - 7496
  • [40] Cathodic electrochemiluminescence immunosensor based on nanocomposites of semiconductor carboxylated g-C3N4 and graphene for the ultrasensitive detection of squamous cell carcinoma antigen
    Li, Xiaojian
    Zhang, Xiaoyue
    Ma, Hongmin
    Wu, Dan
    Zhang, Yong
    Du, Bin
    Wei, Qin
    BIOSENSORS & BIOELECTRONICS, 2014, 55 : 330 - 336