A Monte Carlo model for organ dose reconstruction of patients in pencil beam scanning (PBS) proton therapy for epidemiologic studies of late effects

被引:12
|
作者
Yeom, Yeon Soo [1 ]
Kuzmin, Gleb [2 ]
Griffin, Keith [1 ]
Mille, Matthew [1 ]
Polf, Jerimy [3 ]
Langner, Ulrich [4 ]
Jung, Jae Won [5 ]
Lee, Choonik [6 ]
Ellis, Dillon [5 ]
Shin, Jungwook [7 ]
Lee, Choonsik [1 ]
机构
[1] NCI, Div Canc Epidemiol & Genet, NIH, Rockville, MD 20850 USA
[2] Cleveland Clin, Dept Radiat Oncol, Cleveland, OH 44195 USA
[3] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
[4] Boston Univ, Dept Radiat Oncol, Boston, MA 02215 USA
[5] East Carolina Univ, Dept Phys, Greenville, NC 27858 USA
[6] Univ Michigan, Div Radiat Oncol, Ann Arbor, MI 48109 USA
[7] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
基金
美国国家卫生研究院;
关键词
proton; pencil beam scanning; Monte Carlo; dose reconstruction; RADIOTHERAPY; SIMULATION; EXPOSURES; DOSIMETRY; CANCER; RISK;
D O I
10.1088/1361-6498/ab437d
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Significant efforts such as the Pediatric Proton/Photon Consortium Registry (PPCR) involving multiple proton therapy centers have been made to conduct collaborative studies evaluating outcomes following proton therapy. As a groundwork dosimetry effort for the late effect investigation, we developed a Monte Carlo (MC) model of proton pencil beam scanning (PBS) to estimate organ/tissue doses of pediatric patients at the Maryland Proton Treatment Center (MPTC), one of the proton centers involved in the PPCR. The MC beam modeling was performed using the TOPAS (TOol for PArticle Simulation) MC code and commissioned to match measurement data within 1% for range, and 0.3 mm for spot sizes. The established MC model was then tested by calculating organ/tissue doses for sample intracranial and craniospinal irradiations on whole-body pediatric computational human phantoms. The simulated dose distributions were compared with the treatment planning system dose distributions, showing the 3 mm/3% gamma index passing rates of 94%-99%, validating our simulations with the MC model. The calculated organ/tissue doses per prescribed doses for the craniospinal irradiations (1 mGy Gy(-1) to 1 Gy Gy(-1)) were generally much higher than those for the intracranial irradiations (2.1 mu Gy Gy(-1) to 0.1 Gy Gy(-1)), which is due to the larger field coverage of the craniospinal irradiations. The largest difference was observed at the adrenal dose, i.e. similar to 3000 times. In addition, the calculated organ/tissue doses were compared with those calculated with a simplified MC model, showing that the beam properties (i.e. spot size, spot divergence, mean energy, and energy spread) do not significantly influence dose calculations despite the limited irradiation cases. This implies that the use of the MC model commissioned to the MPTC measurement data might be dosimetrically acceptable for patient dose reconstructions at other proton centers particularly when their measurement data are unavailable. The developed MC model will be used to reconstruct organ/tissue doses for MPTC pediatric patients collected in the PPCR.
引用
收藏
页码:225 / 242
页数:18
相关论文
共 50 条
  • [21] Implementation of a hybrid superfast Monte Carlo-Pencil beam dose optimizer for proton therapy
    Montero, A. M. Barragan
    Souris, K.
    Sanchez-Parcerisa, D.
    Carabe-Fernandez, A.
    Lee, J. A.
    Sterpin, E.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S815 - S816
  • [22] Validation of pencil beam scanning proton therapy with multi-leaf collimator calculated by a commercial Monte Carlo dose engine
    Tominaga, Yuki
    Sakurai, Yusuke
    Miyata, Junya
    Harada, Shuichi
    Akagi, Takashi
    Oita, Masataka
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):
  • [23] Application of Monte Carlo Simulation for Treatment Planning System Commissioning and Dose Calculation for a Pencil Beam Scanning Proton Therapy System
    Hu, H.
    Liu, H.
    Jia, Y.
    Zheng, Y.
    Ding, S.
    Wang, B.
    Li, Y.
    Huang, X.
    Li, Z.
    MEDICAL PHYSICS, 2022, 49 (06) : E860 - E860
  • [24] Improvements in pencil beam scanning proton therapy dose calculation accuracy in brain tumor cases with a commercial Monte Carlo algorithm
    Widesott, Lamberto
    Lorentini, Stefano
    Fracchiolla, Francesco
    Farace, Paolo
    Schwarz, Marco
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (14):
  • [25] Pitfalls in the beam modelling process of Monte Carlo calculations for proton pencil beam scanning
    Winterhalter, Carla
    Aitkenhead, Adam
    Oxley, David
    Richardson, Jenny
    Weber, Damien C.
    MacKay, Ranald, I
    Lomax, Antony J.
    Safai, Sairos
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1107):
  • [26] Characterizing a proton beam scanning system for Monte Carlo dose calculation in patients
    Grassberger, C.
    Lomax, Anthony
    Paganetti, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02): : 633 - 645
  • [27] Determination of surface dose in pencil beam scanning proton therapy
    Kern, A.
    Baeumer, C.
    Kroeninger, K.
    Mertens, L.
    Timmermann, B.
    Walbersloh, J.
    Wulff, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S483 - S483
  • [28] Development and validation of the Dynamic Collimation Monte Carlo simulation package for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Yu, Jen
    Rana, Suresh
    Gutierrez, Alonso N.
    Hill, Patrick M.
    MEDICAL PHYSICS, 2021, 48 (06) : 3172 - 3185
  • [29] Experimental and Monte Carlo characterization of a dynamic collimation system prototype for pencil beam scanning proton therapy
    Smith, Blake R.
    Pankuch, Mark
    Hyer, Daniel E.
    Culberson, Wesley S.
    MEDICAL PHYSICS, 2020, 47 (10) : 5343 - 5356
  • [30] An Optimized Approach for Spot Placement in Pencil Beam Scanning (PBS) Proton Therapy
    Rehman, M.
    Erhart, K.
    Meeks, S.
    Kelly, P.
    Zeidan, O.
    MEDICAL PHYSICS, 2019, 46 (06) : E140 - E141