A novel-integrated quality assurance phantom for radiographic and nonradiographic radiotherapy localization and positioning systems

被引:11
|
作者
Yu, Amy S. [1 ]
Fowler, Tyler L. [1 ]
Dubrowski, Piotr [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
关键词
localization positioning system; nonradiographic and radiographic QA; quality assurance; radiotherapy; LINEAR-ACCELERATOR; REAL-TIME; RADIOSURGERY;
D O I
10.1002/mp.12950
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeVarious localization and positioning systems utilizing radiographic or nonradiographic methods have been developed to improve the accuracy of radiation treatment. Each quality assurance (QA) procedure requires its own phantom and is independent from each other, so the deviation between each system is unavailable. The purpose of this work is to develop and evaluate a single-integrated QA phantom for different localization and positioning systems. MethodsThe integrated phantom was designed in three-dimensional (3D) CAD software and 3D printed. The phantom was designed with laser alignment marks, a raised letter S on the anterior surface for optical surface monitoring system registration, a core for radiofrequency (RF) tracking system alignment, eight internal fiducials for image alignment, and an isocentric bearing for Winston-Lutz test. Tilt legs and rotational stage were designed for rotational verification of optical surface mapping system and RF tracking system, respectively. The phantom was scanned using a CT scanner and a QA plan was created. This prototype phantom was evaluated against established QA techniques. ResultsThe QA result between the proposed procedure and established QA technique are 1.12 0.31 and 1.14 +/- 0.31 mm, respectively, for RF tracking system and 0.18 +/- 0.06 and 0.18 +/- 0.05 mm for Winston-Lutz test. There is no significant difference for the QA results between the established QA and proposed procedure (P > 0.05, t test). The accuracy of rotational verification for surface mapping system and RF tracking system are less than 0.5 and 1 degrees compared the predefined value. The isocenter deviation of each location system is around l mm. ConclusionWe have designed and evaluated a novel-integrated phantom for radiographic and nonradiographic localization and positioning systems for radiotherapy. With this phantom, we will reduce the variation in measurements and simplify the QA procedures.
引用
收藏
页码:2857 / 2863
页数:7
相关论文
共 50 条
  • [41] Integral test phantom for dosimetric quality assurance of image guided and intensity modulated stereotactic radiotherapy
    Letourneau, Daniel
    Keller, Harald
    Sharpe, Michael B.
    Jaffray, David A.
    MEDICAL PHYSICS, 2007, 34 (05) : 1842 - 1849
  • [42] Daily Quality Assurance for a Six Degrees of Freedom Couch Using a Novel Phantom
    Woods, K.
    Woollard, J.
    Ayan, A.
    Sandu, A.
    Sommerfeld, J.
    Laurel, A.
    Gupta, N.
    MEDICAL PHYSICS, 2015, 42 (06) : 3386 - 3386
  • [43] A quality assurance phantom for the performance evaluation of volumetric micro-CT systems
    Du, Louise Y.
    Umoh, Joseph
    Nikolov, Hristo N.
    Pollmann, Steven I.
    Lee, Ting-Yim
    Holdsworth, David W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (23): : 7087 - 7108
  • [44] First results with a new phantom for quality assurance in deep hyperthermia treatment systems
    Marder, D.
    Brandli, N.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S272 - S272
  • [45] QUALITY ASSURANCE IN VARIOUS RADIATIVE HYPERTHERMIA SYSTEMS APPLYING A PHANTOM WITH LED MATRIX
    SCHNEIDER, CJ
    VANDIJK, JDP
    DELEEUW, AAC
    WUST, P
    BAUMHOER, W
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1994, 10 (05) : 733 - 747
  • [46] EORTC RADIOTHERAPY QUALITY ASSURANCE PLATFORM: ESTABLISHMENT OF AN INTEGRATED CENTRAL REVIEW FACILITY
    Gulyban, A.
    Fenton, P.
    Fairchild, A.
    Aird, E.
    Gregoire, V.
    Lacombe, D.
    Matzinger, O.
    Poortmans, P.
    Baumert, B.
    Pascal, R.
    Weber, D. C.
    Hurkmans, C.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S71 - S72
  • [47] Commissioning and Quality Assurance of an Integrated System for Patient Positioning and Setup Verification in Particle Therapy
    Pella, A.
    Riboldi, M.
    Tagaste, B.
    Bianculli, D.
    Desplanques, M.
    Fontana, G.
    Cerveri, P.
    Seregni, M.
    Fattori, G.
    Orecchia, R.
    Baroni, G.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2014, 13 (04) : 303 - 314
  • [48] A case study in integrated quality assurance for performance management systems
    Peyton, Liam
    Zhan, Bo
    Stepien, Bernard
    MSVVEIS 2008: MODELLING, SIMULATION, VERIFICATION AND VALIDATION OF ENTERPRISE INFORMATION SYSTEMS, 2008, : 129 - 138
  • [49] Statistical process control for quality assurance of patient positioning during head-and-neck radiotherapy
    Louwe, R.
    Moore, S.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S163 - S164
  • [50] Development of a Quality Assurance Phantom for Proton Radiographic Images Using the MEVION Spot Scanning Proton Therapy System
    Pelas, C.
    Richards, Z.
    Alsbou, N.
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2020, 47 (06) : E527 - E527