A novel-integrated quality assurance phantom for radiographic and nonradiographic radiotherapy localization and positioning systems

被引:11
|
作者
Yu, Amy S. [1 ]
Fowler, Tyler L. [1 ]
Dubrowski, Piotr [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
关键词
localization positioning system; nonradiographic and radiographic QA; quality assurance; radiotherapy; LINEAR-ACCELERATOR; REAL-TIME; RADIOSURGERY;
D O I
10.1002/mp.12950
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeVarious localization and positioning systems utilizing radiographic or nonradiographic methods have been developed to improve the accuracy of radiation treatment. Each quality assurance (QA) procedure requires its own phantom and is independent from each other, so the deviation between each system is unavailable. The purpose of this work is to develop and evaluate a single-integrated QA phantom for different localization and positioning systems. MethodsThe integrated phantom was designed in three-dimensional (3D) CAD software and 3D printed. The phantom was designed with laser alignment marks, a raised letter S on the anterior surface for optical surface monitoring system registration, a core for radiofrequency (RF) tracking system alignment, eight internal fiducials for image alignment, and an isocentric bearing for Winston-Lutz test. Tilt legs and rotational stage were designed for rotational verification of optical surface mapping system and RF tracking system, respectively. The phantom was scanned using a CT scanner and a QA plan was created. This prototype phantom was evaluated against established QA techniques. ResultsThe QA result between the proposed procedure and established QA technique are 1.12 0.31 and 1.14 +/- 0.31 mm, respectively, for RF tracking system and 0.18 +/- 0.06 and 0.18 +/- 0.05 mm for Winston-Lutz test. There is no significant difference for the QA results between the established QA and proposed procedure (P > 0.05, t test). The accuracy of rotational verification for surface mapping system and RF tracking system are less than 0.5 and 1 degrees compared the predefined value. The isocenter deviation of each location system is around l mm. ConclusionWe have designed and evaluated a novel-integrated phantom for radiographic and nonradiographic localization and positioning systems for radiotherapy. With this phantom, we will reduce the variation in measurements and simplify the QA procedures.
引用
收藏
页码:2857 / 2863
页数:7
相关论文
共 50 条
  • [31] Towards Quality Assurance of 4D Radiotherapy Using a Deformable Lung Phantom
    Serban, M.
    Alexander, A.
    Seuntjens, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [32] A simple phantom for calibration and quality assurance of treatment planning systems (supplement)
    Pandikow, B.
    Zeitschrift fur Medizinische Physik, 2000, 10 (04): : 279 - 282
  • [33] ASPECTS OF QUALITY ASSURANCE - EFFECTS OF SYSTEMATIC-ERRORS DUE TO APPLICATOR POSITIONING IN PHANTOM AND INVIVO
    LOVISOLO, G
    PATERNO, A
    ADAMI, M
    MARINO, C
    PADOVANI, L
    STRAHLENTHERAPIE, 1985, 161 (09) : 543 - 543
  • [34] Automated Image Quality Assessment of Radiographic Systems Using An Anthropomorphic Phantom
    Wells, J.
    Wilson, J.
    Zhang, Y.
    Samei, E.
    Ravin, Carl E.
    MEDICAL PHYSICS, 2014, 41 (06) : 152 - 152
  • [35] Using the ACR CT accreditation phantom for routine image quality assurance on both CT and CBCT imaging systems in a radiotherapy environment
    Hobson, Maritza A.
    Soisson, Emilie T.
    Davis, Stephen D.
    Parker, William
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (04): : 226 - 239
  • [36] Design of an integrated quality assurance strategy in production systems
    Battini, Daria
    Faccio, Maurizio
    Persona, Alessandro
    Sgarbossa, Fabio
    INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 2012, 50 (06) : 1682 - 1701
  • [37] The use of photostimulable phosphor systems for periodic quality assurance in radiotherapy
    Conte, L.
    Bianchi, C.
    Cassani, E.
    Mondardini, M.
    Mordacchini, C.
    Novario, R.
    Strocchi, S.
    Stucchi, P.
    Tanzi, F.
    PHYSICA MEDICA, 2008, 24 (01) : 34 - 37
  • [38] THE DEVELOPMENT OF QUALITY ASSURANCE FOR SHEFFIELDS RADIOTHERAPY TREATMENT PLANNING SYSTEMS
    WHILDE, NJ
    CONWAY, J
    BOMFORD, CK
    BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (792): : 1182 - 1185
  • [39] An integrated quality assurance phantom for frameless single-isocenter multitarget stereotactic radiosurgery
    Capaldi, Dante P., I
    Skinner, Lawrie B.
    Dubrowski, Piotr
    Yu, Amy S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (11):
  • [40] QUALITY ASSURANCE CONTROL IN THE EORTC COOPERATIVE GROUP OF RADIOTHERAPY .3. INTERCOMPARISON IN AN ANATOMICAL PHANTOM
    JOHANSSON, KA
    HORIOT, JC
    VANDERSCHUEREN, E
    RADIOTHERAPY AND ONCOLOGY, 1987, 9 (04) : 289 - 298