A novel-integrated quality assurance phantom for radiographic and nonradiographic radiotherapy localization and positioning systems

被引:11
|
作者
Yu, Amy S. [1 ]
Fowler, Tyler L. [1 ]
Dubrowski, Piotr [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
关键词
localization positioning system; nonradiographic and radiographic QA; quality assurance; radiotherapy; LINEAR-ACCELERATOR; REAL-TIME; RADIOSURGERY;
D O I
10.1002/mp.12950
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeVarious localization and positioning systems utilizing radiographic or nonradiographic methods have been developed to improve the accuracy of radiation treatment. Each quality assurance (QA) procedure requires its own phantom and is independent from each other, so the deviation between each system is unavailable. The purpose of this work is to develop and evaluate a single-integrated QA phantom for different localization and positioning systems. MethodsThe integrated phantom was designed in three-dimensional (3D) CAD software and 3D printed. The phantom was designed with laser alignment marks, a raised letter S on the anterior surface for optical surface monitoring system registration, a core for radiofrequency (RF) tracking system alignment, eight internal fiducials for image alignment, and an isocentric bearing for Winston-Lutz test. Tilt legs and rotational stage were designed for rotational verification of optical surface mapping system and RF tracking system, respectively. The phantom was scanned using a CT scanner and a QA plan was created. This prototype phantom was evaluated against established QA techniques. ResultsThe QA result between the proposed procedure and established QA technique are 1.12 0.31 and 1.14 +/- 0.31 mm, respectively, for RF tracking system and 0.18 +/- 0.06 and 0.18 +/- 0.05 mm for Winston-Lutz test. There is no significant difference for the QA results between the established QA and proposed procedure (P > 0.05, t test). The accuracy of rotational verification for surface mapping system and RF tracking system are less than 0.5 and 1 degrees compared the predefined value. The isocenter deviation of each location system is around l mm. ConclusionWe have designed and evaluated a novel-integrated phantom for radiographic and nonradiographic localization and positioning systems for radiotherapy. With this phantom, we will reduce the variation in measurements and simplify the QA procedures.
引用
收藏
页码:2857 / 2863
页数:7
相关论文
共 50 条
  • [1] A Novel Integrated Quality Assurance Phantom for Radiographic and Nonradiographic Radiotherapy Localization and Positioning Systems
    Fowler, T.
    Yu, Amy S.
    MEDICAL PHYSICS, 2017, 44 (06) : 3060 - 3060
  • [2] Quality assurance for nonradiographic radiotherapy localization and positioning systems: Report of Task Group 147
    Willoughby, Twyla
    Lehmann, Joerg
    Bencomo, Jose A.
    Jani, Shirish K.
    Santanam, Lakshmi
    Sethi, Anil
    Solberg, Timothy D.
    Tome, Wolfgang A.
    Waldron, Timothy J.
    MEDICAL PHYSICS, 2012, 39 (04) : 1728 - 1747
  • [3] Evaluation of a Novel-Integrated Quality Assurance Phantom for Winston-Lutz Test
    Rusnak, A.
    Klein, E.
    Yang, Y.
    MEDICAL PHYSICS, 2022, 49 (06) : E948 - E949
  • [4] An Integrated Stereotactic Radiosurgery Quality Assurance Phantom for Dosimetry and Coincidence Verification of Multiple Positioning Systems
    Skinner, L.
    Dubrowski, P.
    Capaldi, D.
    Yu, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E199 - E200
  • [5] Streamlined Quality Assurance on Positioning Guidance Systems with Single Phantom Setup
    Du, Y.
    Zhou, S.
    Li, J.
    Yu, S.
    Yue, H.
    Wang, M.
    Wu, H.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1454 - S1455
  • [6] Phantom for Quality assurance of the Isocenter in High precision radiotherapy
    Hofmann, R.
    Weber, U.
    Jentzsch, M.
    Wittig, A.
    Engenhart-Cabillic, R.
    Zink, K.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 83 - 83
  • [7] QUALITY ASSURANCE FOR DIGITAL RADIOGRAPHIC SYSTEMS
    GOULD, R
    MEDICAL PHYSICS, 1984, 11 (03) : 418 - 418
  • [8] A novel anthropomorphic multimodality phantom for MRI-based radiotherapy quality assurance testing
    Singhrao, Kamal
    Fu, Jie
    Wu, Holden H.
    Hu, Peng
    Kishan, Amar U.
    Chin, Robert K.
    Lewis, John H.
    MEDICAL PHYSICS, 2020, 47 (04) : 1443 - 1451
  • [9] A novel phantom design for brachytherapy quality assurance
    Gholami, S.
    Mirzaei, H. R.
    Artaee, A. Jabbary
    Jaberi, R.
    Nedaie, H. A.
    Mandavi, S. Rabi
    Bolookat, E. Rajah
    Meigooni, A. S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (01): : 67 - 71
  • [10] A deformable phantom for quality assurance in 4D radiotherapy
    Margeanu, M.
    Heath, E.
    Stroian, G.
    Seuntjens, J.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S80 - S81