Perfusion measurements by micro-CT using prior image constrained compressed sensing (PICCS): initial phantom results

被引:44
|
作者
Nett, Brian E. [1 ]
Brauweiler, Robert [2 ]
Kalender, Willi [2 ]
Rowley, Howard [3 ]
Chen, Guang-Hong [1 ,3 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] Univ Erlangen Nurnberg, Inst Med Phys, D-8520 Erlangen, Germany
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 08期
基金
美国国家卫生研究院;
关键词
HIGH-RESOLUTION MEASUREMENT; BRAIN TRANSFER CONSTANTS; TRACER BOLUS PASSAGES; QUANTITATIVE ASSESSMENT; COMPUTED-TOMOGRAPHY; TUMOR PERFUSION; DYNAMIC CT; PERFORMANCE EVALUATION; GRAPHICAL EVALUATION; CEREBRAL PERFUSION;
D O I
10.1088/0031-9155/55/8/014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Micro-CT scanning has become an accepted standard for anatomical imaging in small animal disease and genome mutation models. Concurrently, perfusion imaging via tracking contrast dynamics after injection of an iodinated contrast agent is a well-established tool for clinical CT scanners. However, perfusion imaging is not yet commercially available on the micro-CT platform due to limitations in both radiation dose and temporal resolution. Recent hardware developments in micro-CT scanners enable continuous imaging of a given volume through the use of a slip-ring gantry. Now that dynamic CT imaging is feasible, data may be acquired to measure tissue perfusion using a micro-CT scanner (CT Imaging, Erlangen, Germany). However, rapid imaging using micro-CT scanners leads to high image noise in individual time frames. Using the standard filtered backprojection (FBP) image reconstruction, images are prohibitively noisy for calculation of voxel-by-voxel perfusion maps. In this study, we apply prior image constrained compressed sensing (PICCS) to reconstruct images with significantly lower noise variance. In perfusion phantom experiments performed on a micro-CT scanner, the PICCS reconstruction enabled a reduction to 1/16 of the noise variance of standard FBP reconstruction, without compromising the spatial or temporal resolution. This enables a significant increase in dose efficiency, and thus, significantly less exposure time is needed to acquire images amenable to perfusion processing. This reduction in required irradiation time enables voxel-by-voxel perfusion maps to be generated on micro-CT scanners. Sample perfusion maps using a deconvolution-based perfusion analysis are included to demonstrate the improvement in image quality using the PICCS algorithm.
引用
收藏
页码:2333 / 2350
页数:18
相关论文
共 50 条
  • [31] Material Decomposition Using Spectral Prior Image Constrained Compressed Sensing
    Tao, S.
    Rajendran, K.
    McCollough, C.
    Leng, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E392 - E392
  • [32] Dual energy CT using slow kVp switching acquisition and prior image constrained compressed sensing
    Szczykutowicz, Timothy P.
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (21): : 6411 - 6429
  • [33] Low Dose Flat-Panel Cone-Beam CT and Tomosynthesis for Interventional Guidance Via Prior Image Constrained Compressed Sensing (PICCS)
    Nett, B.
    Tang, J.
    Leng, S.
    Aagaard-Kienitz, B.
    Chen, G. H.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [34] Time-resolved cardiac interventional cone-beam CT reconstruction from fully truncated projections using the prior image constrained compressed sensing (PICCS) algorithm
    Lauzier, Pascal Theriault
    Tang, Jie
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09):
  • [35] A Performance Comparison between Prior Image Constrained Compressed Sensing and ASiR in Pediatric CT
    Tang, J.
    Chen, G-H
    MEDICAL PHYSICS, 2011, 38 (06)
  • [36] Discriminative Prior - Prior Image Constrained Compressed Sensing Reconstruction for Low-Dose CT Imaging
    Yang Chen
    Jin Liu
    Lizhe Xie
    Yining Hu
    Huazhong Shu
    Limin Luo
    Libo Zhang
    Zhiguo Gui
    Gouenou Coatrieux
    Scientific Reports, 7
  • [37] Discriminative Prior - Prior Image Constrained Compressed Sensing Reconstruction for Low-Dose CT Imaging
    Chen, Yang
    Liu, Jin
    Xie, Lizhe
    Hu, Yining
    Shu, Huazhong
    Luo, Limin
    Zhang, Libo
    Gui, Zhiguo
    Coatrieux, Gouenou
    SCIENTIFIC REPORTS, 2017, 7
  • [38] Dose Reduction in Digital Breast Tomosynthesis with the Dose Reduction Prior Image Constrained Compressed Sensing (DR-PICCS) Algorithm
    Garrett, J.
    Tang, J.
    Zhang, Y.
    Ruth, C.
    Jing, Z.
    Chen, G. H.
    MEDICAL PHYSICS, 2012, 39 (06) : 3916 - 3916
  • [40] Deep learning enabled prior image constrained compressed sensing (DL-PICCS) reconstruction framework for sparse-view reconstruction
    Zhang, Chengzhu
    Li, Yinsheng
    Chen, Guang-Hong
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312