Perfusion measurements by micro-CT using prior image constrained compressed sensing (PICCS): initial phantom results

被引:44
|
作者
Nett, Brian E. [1 ]
Brauweiler, Robert [2 ]
Kalender, Willi [2 ]
Rowley, Howard [3 ]
Chen, Guang-Hong [1 ,3 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] Univ Erlangen Nurnberg, Inst Med Phys, D-8520 Erlangen, Germany
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 08期
基金
美国国家卫生研究院;
关键词
HIGH-RESOLUTION MEASUREMENT; BRAIN TRANSFER CONSTANTS; TRACER BOLUS PASSAGES; QUANTITATIVE ASSESSMENT; COMPUTED-TOMOGRAPHY; TUMOR PERFUSION; DYNAMIC CT; PERFORMANCE EVALUATION; GRAPHICAL EVALUATION; CEREBRAL PERFUSION;
D O I
10.1088/0031-9155/55/8/014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Micro-CT scanning has become an accepted standard for anatomical imaging in small animal disease and genome mutation models. Concurrently, perfusion imaging via tracking contrast dynamics after injection of an iodinated contrast agent is a well-established tool for clinical CT scanners. However, perfusion imaging is not yet commercially available on the micro-CT platform due to limitations in both radiation dose and temporal resolution. Recent hardware developments in micro-CT scanners enable continuous imaging of a given volume through the use of a slip-ring gantry. Now that dynamic CT imaging is feasible, data may be acquired to measure tissue perfusion using a micro-CT scanner (CT Imaging, Erlangen, Germany). However, rapid imaging using micro-CT scanners leads to high image noise in individual time frames. Using the standard filtered backprojection (FBP) image reconstruction, images are prohibitively noisy for calculation of voxel-by-voxel perfusion maps. In this study, we apply prior image constrained compressed sensing (PICCS) to reconstruct images with significantly lower noise variance. In perfusion phantom experiments performed on a micro-CT scanner, the PICCS reconstruction enabled a reduction to 1/16 of the noise variance of standard FBP reconstruction, without compromising the spatial or temporal resolution. This enables a significant increase in dose efficiency, and thus, significantly less exposure time is needed to acquire images amenable to perfusion processing. This reduction in required irradiation time enables voxel-by-voxel perfusion maps to be generated on micro-CT scanners. Sample perfusion maps using a deconvolution-based perfusion analysis are included to demonstrate the improvement in image quality using the PICCS algorithm.
引用
收藏
页码:2333 / 2350
页数:18
相关论文
共 50 条
  • [1] Low Dose Myocardial CT Perfusion Measurements Using Prior Image Constrained Compressed Sensing (PICCS)
    Nett, B.
    Tang, J.
    Speidel, M.
    Chen, G-H
    MEDICAL PHYSICS, 2008, 35 (06) : 2870 - +
  • [2] Prior Image Constrained Compressed Sensing (PICCS)
    Chen, Guang-Hong
    Tang, Jie
    Leng, Shuai
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2008: THE NINTH CONFERENCE ON BIOMEDICAL THERMOACOUSTICS, OPTOACOUSTICS, AND ACOUSTIC-OPTICS, 2008, 6856
  • [3] GPU implementation of Prior Image Constrained Compressed Sensing (PICCS)
    Nett, Brian E.
    Tang, Jie
    Chen, Guang-Hong
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [4] A new approach to solving the prior image constrained compressed sensing (PICCS) with applications in CT image reconstruction
    Tang, Yuchao
    Long, Chunxiang
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [5] Dose Reduction using Prior Image Constrained Compressed Sensing (DR-PICCS)
    Tang, Jie
    Lauzier, Pascal Theriault
    Chen, Guang-Hong
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [6] Dose Reduction in CT Using Non-Convex Prior Image Constrained Compressed Sensing NC-PICCS
    Giraldo, J. C. Ramirez
    Leng, S.
    Trzasko, J.
    Yu, L.
    Manduca, A.
    McCollough, C.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [7] A Novel Denoising Method for Dual Energy CT Based on Prior Image Constrained Compressed Sensing (PICCS)
    Szczykutowicz, T. P.
    Chen, G. -H
    MEDICAL PHYSICS, 2011, 38 (06)
  • [8] Impact of Norm Selections on the Performance of Prior Image Constrained Compressed Sensing (PICCS)
    Li, Yinsheng
    Tang, Jie
    Chen, Guang-Hong
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [9] Tumor Motion Assessment with 4D Cone Beam CT Using Prior Image Constrained Compressed Sensing (PICCS)
    Qi, Z.
    Chen, G.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [10] Impact of noise level and edge sharpness of a prior image on the performance of Prior Image Constrained Compressed Sensing (PICCS)
    Tao, Yinghua
    Tang, Jie
    Speidel, Michael
    Chen, Guang-Hong
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668