THE CERAMIC MODULAR HEAD IMPROVEMENT IN THE DESIGN OF A TOTAL HIP REPLACEMENT

被引:6
|
作者
Pakhaliuk, Vladimir [1 ]
Poliakov, Aleksandr [1 ]
Fedotov, Ivan [2 ]
机构
[1] Sevastopol State Univ, Univ Skaya Str 33, Sevastopol 299053, Russia
[2] Natl Res Nucl Univ MEPHI, Moscow, Russia
基金
俄罗斯基础研究基金会;
关键词
Total hip replacement; Ceramic friction couple; Modular ceramic ball head; Brazing;
D O I
10.22190/FUME201212010P
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
For the first time, a design of a modular ceramic ball head of a total hip joint replacement (THR) friction pair has been developed, which has the properties of a metal in conjunction with the stem neck and the properties of a ceramics on bearing surface of the pair. This is achieved by creating a low-cost, low-toxic, durable fixed connection of the head made of alumina or zirconia ceramics and the titanium-based alloy sleeve to obtain a brazed joint that is efficient in human synovial fluid. With the help of finite element analysis, a quantitative assessment of the strength and rigidity of the proposed head design was performed and its use in modern hip arthroplasty was indicated. The approbation of the proposed design solutions for creating a THR ceramic head with a titanium-based alloy sleeve brazed was carried out.
引用
收藏
页码:67 / 78
页数:12
相关论文
共 50 条
  • [31] Ceramic Head Fracture in Ceramic-on-Polyethylene Total Hip Arthroplasty
    Nho, Jae-Hwi
    Park, Jong-Seok
    Song, Ui-Seoub
    Kim, Woo-Jong
    Suh, You-Sung
    YONSEI MEDICAL JOURNAL, 2013, 54 (06) : 1550 - 1553
  • [32] Fracture of an alumina ceramic head in total hip arthroplasty
    Higuchi, F
    Shiba, N
    Inoue, A
    Wakebe, I
    JOURNAL OF ARTHROPLASTY, 1995, 10 (06): : 851 - 854
  • [33] Ceramic femoral head fractures in total hip arthroplasty
    Fritsch, EW
    Gleitz, M
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (328) : 129 - 136
  • [34] Catastrophic failure of the Elite Plus total hip replacement, with a Hylamer acetabulum and Zirconia ceramic femoral head
    Cohen, J
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (01): : 148 - 148
  • [35] Catastrophic failure of the Elite Plus total hip replacement, with a Hylamer acetabulum and Zirconia ceramic femoral head
    Norton, MR
    Yarlagadda, R
    Anderson, GH
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05): : 631 - 635
  • [36] Modular Neck in Primary Total Hip Replacement - A Justifiable Risk?
    Kretzer, J. P.
    Ewerbeck, V.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2015, 153 (03): : 312 - 316
  • [37] Total hip replacement in avascular femoral head necrosis
    Betsch, M.
    Tingart, M.
    Driessen, A.
    Quack, V.
    Rath, B.
    ORTHOPADE, 2018, 47 (09): : 751 - 756
  • [38] Osteonecrosis of the femoral head THE TOTAL HIP REPLACEMENT SOLUTION
    Issa, K.
    Pivec, R.
    Kapadia, B. H.
    Banerjee, S.
    Mont, M. A.
    BONE & JOINT JOURNAL, 2013, 95B (11): : 46 - 50
  • [39] Tips and tricks: Fracture of a ceramic insert with modern ceramic total hip replacement
    Min, B. -W.
    Song, K. -S.
    Kang, C. -H.
    Lee, K. -J.
    Bae, K. -C.
    Cho, C. -H.
    Won, Y. -Y.
    Bioceramics and Alternative Bearings in Joint Arthroplasty, 2007, : 311 - 318
  • [40] Alumina ceramic-on-ceramic total hip replacement with a layered acetabular component
    Hasegawa, M.
    Sudo, A.
    Uchida, A.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (07): : 877 - 882