THE CERAMIC MODULAR HEAD IMPROVEMENT IN THE DESIGN OF A TOTAL HIP REPLACEMENT

被引:6
|
作者
Pakhaliuk, Vladimir [1 ]
Poliakov, Aleksandr [1 ]
Fedotov, Ivan [2 ]
机构
[1] Sevastopol State Univ, Univ Skaya Str 33, Sevastopol 299053, Russia
[2] Natl Res Nucl Univ MEPHI, Moscow, Russia
基金
俄罗斯基础研究基金会;
关键词
Total hip replacement; Ceramic friction couple; Modular ceramic ball head; Brazing;
D O I
10.22190/FUME201212010P
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
For the first time, a design of a modular ceramic ball head of a total hip joint replacement (THR) friction pair has been developed, which has the properties of a metal in conjunction with the stem neck and the properties of a ceramics on bearing surface of the pair. This is achieved by creating a low-cost, low-toxic, durable fixed connection of the head made of alumina or zirconia ceramics and the titanium-based alloy sleeve to obtain a brazed joint that is efficient in human synovial fluid. With the help of finite element analysis, a quantitative assessment of the strength and rigidity of the proposed head design was performed and its use in modern hip arthroplasty was indicated. The approbation of the proposed design solutions for creating a THR ceramic head with a titanium-based alloy sleeve brazed was carried out.
引用
收藏
页码:67 / 78
页数:12
相关论文
共 50 条
  • [21] Total hip replacement with a zirconium oxide ceramic femoral head -: A randomised roentgen stereophotogrammetric study
    von Schewelov, T
    Sanzén, L
    Önsten, I
    Carlsson, Å
    Besjakov, J
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (12): : 1631 - 1635
  • [22] A comparative study of the performance of metallic and ceramic femoral head components in total replacement hip joints
    Dowson, D
    WEAR, 1995, 190 (02) : 171 - 183
  • [23] A modular femoral neck and head system works well in cementless total hip replacement for patients with developmental dysplasia of the hip
    Sakai, T.
    Ohzono, K.
    Nishii, T.
    Miki, H.
    Takao, M.
    Sugano, N.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (06): : 770 - 776
  • [24] Ceramic/ceramic total hip replacement: The American experience with stryker implants
    Bierbaum, BE
    D'Antonio, J
    Capello, W
    Manley, M
    Deshmukh, R
    BIOCERAMICS IN JOINT ARTHROPLASTY, 2004, : 21 - 34
  • [25] Delayed fracture of a ceramic insert with modern ceramic total hip replacement
    Min, Byung-Woo
    Song, Kwang-Soon
    Kang, Chul-Hyung
    Bae, Ki-Cheol
    Won, Ye-Yeon
    Lee, Kwon-Yong
    JOURNAL OF ARTHROPLASTY, 2007, 22 (01): : 136 - 139
  • [26] Catastrophic failure of modular zirconia-ceramic femoral head components after total hip arthroplasty
    Hummer, CD
    Rothman, RH
    Hozack, WJ
    JOURNAL OF ARTHROPLASTY, 1995, 10 (06): : 848 - 850
  • [27] Ceramic bearings in total hip replacement: a retrieval analysis
    Chen, D.
    Lin, S.
    Cutrera, N.
    Padgett, D.
    Wright, T.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2010, 61 (01): : 43 - 49
  • [28] Cementless Ceramic-on-Ceramic Total Hip Replacement in Children and Adolescents
    Trisolino, Giovanni
    Stallone, Stefano
    Castagnini, Francesco
    Bordini, Barbara
    Cosentino, Monica
    Lucchini, Stefano
    Zarantonello, Paola
    Ferrari, Daniele
    Dallari, Dante
    Traina, Francesco
    CHILDREN-BASEL, 2021, 8 (10):
  • [29] Fracture analysis of ceramic heads for total hip replacement
    Willmann, G
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2001, 32 (07) : 591 - 600