Comparison of two commercial 2D-array phantoms for patient-specific QA of stereotactic treatments

被引:0
|
作者
Nevelsky, A. [1 ]
Borzov, E. [1 ]
Daniel, S. [1 ]
Bar-Deroma, R. [1 ]
机构
[1] Rambam Hlth Care Campus, Fac Med, Oncol, Haifa, Israel
关键词
D O I
10.1016/S0167-8140(18)32045-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
EP-1736
引用
收藏
页码:S929 / S930
页数:2
相关论文
共 50 条
  • [21] Tomotherapy Patient-Specific Delivery QA Using Exit Detector Array
    Chen, Y.
    Reeher, M.
    Mo, X.
    Chen, M.
    Olivera, G.
    Key, S.
    Parnell, D. W.
    Galmarini, D.
    Lu, W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S740 - S740
  • [22] Comparison of 2D and 3D Gamma Analysis in Patient-Specific QA for Prostate VMAT Plans
    Clemente, F.
    Perez, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 240 - +
  • [23] Patient-Specific QA of Intensity-Modulated Arc Therapy with 2D Diode Array: Initial Experience
    Tang, G.
    Yi, B.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [24] Reduction of Systematic Dosimetric Uncertainties in VMAT Treatments Triggered by Patient-Specific QA
    Mijnheer, B.
    Janssen, T.
    van Mourik, A.
    Kaas, J.
    Damen, E.
    Mans, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E245 - E245
  • [25] Intercomparison of Patient-Specific IMRT QA Devices for Small-Field, Stereotactic VMAT Treatments Using Gamma Index Analysis
    Alvarez, D.
    Wieczorek, D.
    Mishra, V.
    Gutierrez, A.
    MEDICAL PHYSICS, 2017, 44 (06) : 2957 - 2957
  • [26] Refinement of MLC modeling improves commercial QA dosimetry system for SRS and SBRT patient-specific QA
    Hillman, Yair
    Kim, Josh
    Chetty, Indrin
    Wen, Ning
    MEDICAL PHYSICS, 2018, 45 (04) : 1351 - 1359
  • [27] Comparison of Single and Dual Material 3D Printed Patient-Specific Radiotherapy Phantoms
    Craft, D. F.
    Peters, M.
    Baltz, G.
    Howell, R. M.
    MEDICAL PHYSICS, 2017, 44 (06) : 2877 - 2877
  • [28] Comparative performance analysis of 2D and 3D gamma metrics for patient specific QA in VMAT using Octavius 4D with 2D-Array 1500
    Pal, Bipasha
    Pal, Angshuman
    Bag, Santanu
    Ali, Md Abbas
    Das, Suresh
    Palit, Soura
    Sarkar, Papai
    Mallik, Suman
    Goswami, Jyotirup
    Das, Sayan
    Manir, Kazi Sazzad
    Sen, Arijit
    Mondol, Monidipa
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 91 : 18 - 27
  • [29] Comparison of Measurements From Two Diode Array QA Devices to Deep Point Dose Measurements with Two Treatment Planning Model Settings for Brain VMAT SRT Patient-Specific QA
    Weethee, B.
    Cheung, J.
    Perez-Andujar, A.
    Sudhyadhom, A.
    Chen, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3534 - 3534
  • [30] Assessment of radiobiological metrics applied to patient-specific QA process of VMAT prostate treatments
    Clemente-Gutierrez, Francisco
    Perez-Vara, Consuelo
    Clavo-Herranz, Maria H.
    Lopez-Carrizosa, Concepcion
    Perez-Regadera, Jose
    Ibanez-Villoslada, Carmen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 341 - 367