The validity of the GENEActiv wrist-worn accelerometer for measuring adult sedentary time in free living

被引:59
|
作者
Pavey, Toby G. [1 ]
Gomersall, Sjaan R. [1 ]
Clark, Bronwyn K. [1 ]
Brown, Wendy J. [1 ]
机构
[1] Univ Queensland, Sch Human Movement Studies, Ctr Res Exercise Phys Act & Hlth CRExPAH, Brisbane, Qld, Australia
关键词
Accelerometer; Sedentary; Posture; Adults; Objective; SITTING TIME; ENERGY-EXPENDITURE; ACTIVITY MONITOR; VALIDATION; BEHAVIOR; HIP;
D O I
10.1016/j.jsams.2015.04.007
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Objectives: Based on self-reported measures, sedentary time has been associated with chronic disease and mortality. This study examined the validity of the wrist-worn GENEactiv accelerometer for measuring sedentary time (i.e. sitting and lying) by posture classification, during waking hours in free living adults. Design: Fifty-seven participants (age = 18-55 years 52% male) were recruited using convenience sampling from a large metropolitan Australian university. Methods: Participants wore a GENEActiv accelerometer on their non-dominant wrist and an activPAL device attached to their right thigh for 24-h (00:00 to 23:59:59). Pearson's Correlation Coefficient was used to examine the convergent validity of the GENEActiv and the activPAL for estimating total sedentary time during waking hours. Agreement was illustrated using Bland and Altman plots, and intra-individual agreement for posture was assessed with the Kappa statistic. Results: Estimates of average total sedentary time over 24-h were 623 (SD 103) min/day from the GENEActiv, and 626 (SD 123) min/day from the activPAL, with an Intraclass Correlation Coefficient of 0.80 (95% confidence intervals 0.68-0.88). Bland and Altman plots showed slight underestimation of mean total sedentary time for GENEActiv relative to activPAL (mean difference: -3.44 min/day), with moderate limits of agreement (-144 to 137 min/day). Mean Kappa for posture was 0.53 (SD 0.12), indicating moderate agreement for this sample at the individual level. Conclusions: The estimation of sedentary time by posture classification of the wrist-worn GENEActiv accelerometer was comparable to the activPAL. The GENEActiv may provide an alternative, easy to wear device based measure for descriptive estimates of sedentary time in population samples. (C) 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:395 / 399
页数:5
相关论文
共 50 条
  • [31] Hip and Wrist-Worn Accelerometer Data Analysis for Toddler Activities
    Kwon, Soyang
    Zavos, Patricia
    Nickele, Katherine
    Sugianto, Albert
    Albert, Mark V.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (14)
  • [32] An Elderly Fall Detection using a Wrist-worn Accelerometer and Barometer
    Jatesiktat, Prayook
    Ang, Wei Tech
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 125 - 130
  • [33] Activity Monitoring with a Wrist-Worn, Accelerometer-Based Device
    Lin, Wen-Yen
    Verma, Vijay Kumar
    Lee, Ming-Yih
    Lai, Chao-Sung
    MICROMACHINES, 2018, 9 (09)
  • [34] Accuracy of Wrist-Worn Photoplethysmography Devices at Measuring Heart Rate in the Laboratory and During Free-Living Activities
    Giggins, Oonagh M.
    Doyle, Julie
    Sojan, Nisanth
    Moran, Orla
    Crabtree, Daniel R.
    Fraser, Matthew
    Muggeridge, David J.
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 6970 - 6973
  • [35] Reliably Measuring Habitual Free-Living Physical Activity with Hip- and Wrist-Worn Activity Monitors
    Webster, Michael D.
    Heil, Daniel P.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (05): : S199 - S199
  • [36] Development of cut-points for determining activity intensity from a wrist-worn ActiGraph accelerometer in free-living adults
    Montoye, Alexander H. K.
    Clevenger, Kimberly A.
    Pfeiffer, Karin A.
    Nelson, Michael Benjamin
    Bock, Joshua M.
    Imboden, Mary T.
    Kaminsky, Leonard A.
    JOURNAL OF SPORTS SCIENCES, 2020, 38 (22) : 2569 - 2578
  • [37] Wrist-Worn Activity Trackers in Laboratory and Free-Living Settings for Patients With Chronic Pain: Criterion Validity Study
    Sjoberg, Veronica
    Westergren, Jens
    Monnier, Andreas
    Lo Martire, Riccardo
    Hagstromer, Maria
    Ang, Bjorn Olov
    Vixner, Linda
    JMIR MHEALTH AND UHEALTH, 2021, 9 (01):
  • [38] Objective Assessment of Strength Training Exercises using a Wrist-Worn Accelerometer
    Conger, Scott A.
    Guo, Jun
    Fulkerson, Scott M.
    Pedigo, Lauren
    Chen, Hao
    Bassett, David R., Jr.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2016, 48 (09) : 1847 - 1855
  • [39] Step-length Estimation using Wrist-worn Accelerometer and GPS
    Kao, Wei-Wen
    Chen, Ching-Kun
    Lin, Jing-Shian
    PROCEEDINGS OF THE 24TH INTERNATIONAL TECHNICAL MEETING OF THE SATELLITE DIVISION OF THE INSTITUTE OF NAVIGATION (ION GNSS 2011), 2011, : 3274 - 3280
  • [40] A Novel Method Of Assessing Dietary Behavior Using a Wrist-Worn Accelerometer
    Winfree, Kyle N.
    Dmitrieva, Natalia O.
    Behrens, Timothy K.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 14 - 14