The validity of the GENEActiv wrist-worn accelerometer for measuring adult sedentary time in free living

被引:59
|
作者
Pavey, Toby G. [1 ]
Gomersall, Sjaan R. [1 ]
Clark, Bronwyn K. [1 ]
Brown, Wendy J. [1 ]
机构
[1] Univ Queensland, Sch Human Movement Studies, Ctr Res Exercise Phys Act & Hlth CRExPAH, Brisbane, Qld, Australia
关键词
Accelerometer; Sedentary; Posture; Adults; Objective; SITTING TIME; ENERGY-EXPENDITURE; ACTIVITY MONITOR; VALIDATION; BEHAVIOR; HIP;
D O I
10.1016/j.jsams.2015.04.007
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Objectives: Based on self-reported measures, sedentary time has been associated with chronic disease and mortality. This study examined the validity of the wrist-worn GENEactiv accelerometer for measuring sedentary time (i.e. sitting and lying) by posture classification, during waking hours in free living adults. Design: Fifty-seven participants (age = 18-55 years 52% male) were recruited using convenience sampling from a large metropolitan Australian university. Methods: Participants wore a GENEActiv accelerometer on their non-dominant wrist and an activPAL device attached to their right thigh for 24-h (00:00 to 23:59:59). Pearson's Correlation Coefficient was used to examine the convergent validity of the GENEActiv and the activPAL for estimating total sedentary time during waking hours. Agreement was illustrated using Bland and Altman plots, and intra-individual agreement for posture was assessed with the Kappa statistic. Results: Estimates of average total sedentary time over 24-h were 623 (SD 103) min/day from the GENEActiv, and 626 (SD 123) min/day from the activPAL, with an Intraclass Correlation Coefficient of 0.80 (95% confidence intervals 0.68-0.88). Bland and Altman plots showed slight underestimation of mean total sedentary time for GENEActiv relative to activPAL (mean difference: -3.44 min/day), with moderate limits of agreement (-144 to 137 min/day). Mean Kappa for posture was 0.53 (SD 0.12), indicating moderate agreement for this sample at the individual level. Conclusions: The estimation of sedentary time by posture classification of the wrist-worn GENEActiv accelerometer was comparable to the activPAL. The GENEActiv may provide an alternative, easy to wear device based measure for descriptive estimates of sedentary time in population samples. (C) 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:395 / 399
页数:5
相关论文
共 50 条
  • [21] MEASURING ACTIVITY IN PATIENTS WITH SARCOIDOSIS - A PILOT TRIAL OF TWO WRIST-WORN ACCELEROMETER DEVICES
    Atkins, Christopher P.
    Jones, Andy P.
    Wilson, Andrew M.
    SARCOIDOSIS VASCULITIS AND DIFFUSE LUNG DISEASES, 2018, 35 (01) : 62 - 68
  • [22] Measuring sedentary behaviors in patients with idiopathic pulmonary fibrosis using wrist-worn accelerometers
    Atkins, Christopher
    Baxter, Mark
    Jones, Andrew
    Wilson, Andrew
    CLINICAL RESPIRATORY JOURNAL, 2018, 12 (02): : 746 - 753
  • [23] The validity of the commercially-available, low-cost, wrist-worn Movband accelerometer during treadmill exercise and free-living physical activity
    Barkley, Jacob E.
    Glickman, Ellen
    Fennell, Curtis
    Kobak, Mallory
    Frank, Megan
    Farnell, Gregory
    JOURNAL OF SPORTS SCIENCES, 2019, 37 (07) : 735 - 740
  • [24] Does Wrist-Worn Accelerometer Wear Compliance Wane over a Free-Living Assessment Period? An NHANES Analysis
    LaMunion, Samuel R.
    Brychta, Robert J.
    Saint-Maurice, Pedro F.
    Matthews, Charles E.
    Chen, Kong Y.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (02) : 209 - 220
  • [25] Physical Activity Intensity Cut-Points for Wrist-Worn GENEActiv in Older Adults
    Fraysse, Francois
    Post, Dannielle
    Eston, Roger
    Kasai, Daiki
    Rowlands, Alex V.
    Parfitt, Gaynor
    FRONTIERS IN SPORTS AND ACTIVE LIVING, 2021, 2
  • [26] Subject Recognition Using Wrist-Worn Triaxial Accelerometer Data
    Mauceri, Stefano
    Smith, Louis
    Sweeney, James
    McDermott, James
    MACHINE LEARNING, OPTIMIZATION, AND BIG DATA, MOD 2017, 2018, 10710 : 574 - 585
  • [27] Validation of the Vivago Wrist-Worn accelerometer in the assessment of physical activity
    Jérémy Vanhelst
    Rémy Hurdiel
    Jacques Mikulovic
    Gilles Bui-Xuân
    Paul Fardy
    Denis Theunynck
    Laurent Béghin
    BMC Public Health, 12
  • [28] Analysis Of Accelerometer Counts During Sedentary Activities In 5-11 Year Old Children Using a Wrist-Worn Accelerometer
    Chandler, Jessica L.
    Beets, Michael W.
    Brazendale, Keith
    Mealing, Breonna A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 1064 - 1064
  • [29] Physical Activity Classification Using the GENEA Wrist-Worn Accelerometer
    Zhang, Shaoyan
    Rowlands, Alex V.
    Murray, Peter
    Hurst, Tina L.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 (04): : 742 - 748
  • [30] Validation of the Vivago Wrist-Worn accelerometer in the assessment of physical activity
    Vanhelst, Jeremy
    Hurdiel, Remy
    Mikulovic, Jacques
    Bui-Xuan, Gilles
    Fardy, Paul
    Theunynck, Denis
    Beghin, Laurent
    BMC PUBLIC HEALTH, 2012, 12