Repeatability and Reproducibility of Anterior Chamber Angle Measurement with Swept-Source Optical Coherence Tomography in Patients with Primary Angle Closure Suspect

被引:3
|
作者
Zhao, Tong [1 ,2 ]
Zhao, Mengya [1 ,3 ]
Xie, Qinghong [1 ]
Fong, Christopher W. [1 ]
Chen, Jeremy [1 ]
Liu, Yingna [1 ]
Feng, Hui [4 ]
Li, Shuning [4 ]
Arnold, Benjamin F. [1 ,5 ]
Aung, Tin [6 ,7 ]
He, Mingguang [8 ,9 ]
Oatts, Julius T. [1 ]
Han, Ying [1 ]
机构
[1] Univ Calif San Francisco, Dept Ophthalmol, 10 Koret Way, San Francisco, CA 94143 USA
[2] China Japan Friendship Hosp, Dept Ophthalmol, Beijing, Peoples R China
[3] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Ophthalmol, Sch Med, Shanghai, Peoples R China
[4] Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China
[5] Univ Calif San Francisco, Francis I Proctor Fdn, San Francisco, CA 94143 USA
[6] Singapore Natl Eye Ctr, Singapore Eye Res Inst, Singapore, Singapore
[7] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Ophthalmol, Singapore, Singapore
[8] Sun Yat Sen Univ, Clin Res Ctr, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou, Peoples R China
[9] Univ Melbourne, Royal Victorian Eye & Ear Hosp, Ctr Eye Res Australia, East Melbourne, Australia
关键词
Anterior chamber; SS-OCT; glaucoma; angle closure; imaging; SCLERAL SPUR;
D O I
10.1080/02713683.2021.1942069
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the inter- and intra-observer reliability of anterior chamber (AC) angle measurements obtained by swept-source optical coherence tomography (SS-OCT). Methods: Forty-eight consecutive patients diagnosed with primary angle closure suspect (PACS) were included. Three masked observers at different training levels (one glaucoma specialist, one ophthalmology resident, and one pre-medical college student) measured 192 SS-OCT images of the PACS patients. One observer (the glaucoma specialist) repeated measurements 1 week later. SS-OCT parameters included: Anterior segment volume, including corneal, AC, and iris volume; anterior segment dimensions, including AC depth and width (ACD, ACW), and lens vault (LV); and angle parameters, including angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), and the trabecular iris angle (TIA). Intraclass correlation coefficients (ICCs) were used to measure reliability. Results: For inter-observer reproducibility, ICCs of corneal, AC, and iris volumes were 0.952 to 0.998. ICCs of ACD at all axes were above 0.989. ICCs of ACW and LV were smallest in the 90 degrees-270 degrees axis (0.751 and 0.768) but not significantly different from other axes. ARA, TISA, and TIA at all angles had significantly smallest ICCs 250 mu m from the scleral spur compared with 500 mu m and 750 mu m. The ICCs comparing observers with different training levels had similar ranges and followed similar trends. For intra-observer repeatability, the smallest ICC was 0.843. Decreasing AC depth correlated with increased inter-observer reproducibility. Conclusions: We found excellent intra-observer repeatability for all SS-OCT parameters. Angle measurements have more variation among the observers when taken 250 mu m from the scleral spur. Shallow AC might lead to more variability for angle parameters. Non-expert observers may be recruited for high-quality image grading with standard training.
引用
收藏
页码:1853 / 1860
页数:8
相关论文
共 50 条
  • [31] Assessment of Circumferential Angle-Closure by the IriseTrabecular Contact Index with Swept-Source Optical Coherence Tomography
    Baskaran, Mani
    Ho, Sue-Wei
    Tun, Tin A.
    How, Alicia C.
    Perera, Shamira A.
    Friedman, David S.
    Aung, Tin
    OPHTHALMOLOGY, 2013, 120 (11) : 2226 - 2231
  • [32] Novel hyperparallel optical coherence tomography for angle closure assessment: comparison with swept-source OCT and gonioscopy
    Porporato, Natalia
    Xu, Benjamin Y.
    Tan, Bingyao
    Chang, Yu Q.
    Tun, Tin A.
    Perera, Shamira
    Husain, Rahat
    Ho, Ching Lin
    Sultana, Rehena
    Aung, Tin
    Schmetterer, Leopold
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2025, 109 (01) : 58 - 63
  • [33] Decreased iris thickness on swept-source optical coherence tomography in patients with primary open-angle glaucoma
    Chen, Zhiqi
    Liang, Xin
    Chen, Wei
    Wang, Ping
    Wang, Junming
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 49 (07): : 696 - 703
  • [34] Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography
    Radhakrishnan, Sunita
    See, Jovina
    Smith, Scott D.
    Nolan, Winifred P.
    Ce, Zheng
    Friedman, David S.
    Huang, David
    Li, Yan
    Aung, Tin
    Chew, Paul T. K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (08) : 3683 - 3688
  • [35] Novel diagnostic indicators for acute angle closure secondary to lens subluxation based on swept-source anterior segment optical coherence tomography
    Tang, Yizhen
    Gao, Yan
    Shi, Yan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [36] Measurement of Scleral Thickness using Swept-Source Optical Coherence Tomography in Patients With Open-Angle Glaucoma and Myopia
    Park, Hae-Young Lopilly
    Lee, Na Young
    Choi, Jin A.
    Park, Chan Kee
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (04) : 876 - 884
  • [37] Accuracy and Repeatability of an Anterior Segment Swept-Source Optical Coherence Tomographer
    Peguda, Rajini
    Kang, Pauline
    Maseedupally, Vinod
    Swarbrick, Helen
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S300 - S306
  • [38] Effect of Pharmacological Pupil Dilatation on Angle Configuration in Untreated Primary Angle Closure Suspects: A Swept Source Anterior Segment Optical Coherence Tomography Study
    Narayanaswamy, Arun
    Baskaran, Mani
    Tun, Tin A.
    Htoon, Hla M.
    Aung, Tin
    JOURNAL OF GLAUCOMA, 2020, 29 (07) : 521 - 528
  • [39] Use of a Novel Anterior Segment Swept-Source Optical Coherence Tomography in Assessing Iris and Iridocorneal Angle Structures
    Najafi, Ahmad
    Park, Sung Chul
    Liebmann, Jeffrey M.
    Ritch, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [40] Zonular instability-associated morphologic features in eyes with primary angle closure disease using the swept-source anterior segment - optical coherence tomography system
    Pei, Xue-Ting
    Wang, Shu-Hua
    Qing, Guo-Ping
    Yu, Xiao-Wei
    Shi, Yan
    Yang, Wen-Li
    Wang, Ning-Li
    Fan, Zhi-Gang
    BMC OPHTHALMOLOGY, 2024, 24 (01)