Repeatability and Reproducibility of Anterior Chamber Angle Measurement with Swept-Source Optical Coherence Tomography in Patients with Primary Angle Closure Suspect

被引:3
|
作者
Zhao, Tong [1 ,2 ]
Zhao, Mengya [1 ,3 ]
Xie, Qinghong [1 ]
Fong, Christopher W. [1 ]
Chen, Jeremy [1 ]
Liu, Yingna [1 ]
Feng, Hui [4 ]
Li, Shuning [4 ]
Arnold, Benjamin F. [1 ,5 ]
Aung, Tin [6 ,7 ]
He, Mingguang [8 ,9 ]
Oatts, Julius T. [1 ]
Han, Ying [1 ]
机构
[1] Univ Calif San Francisco, Dept Ophthalmol, 10 Koret Way, San Francisco, CA 94143 USA
[2] China Japan Friendship Hosp, Dept Ophthalmol, Beijing, Peoples R China
[3] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Ophthalmol, Sch Med, Shanghai, Peoples R China
[4] Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China
[5] Univ Calif San Francisco, Francis I Proctor Fdn, San Francisco, CA 94143 USA
[6] Singapore Natl Eye Ctr, Singapore Eye Res Inst, Singapore, Singapore
[7] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Ophthalmol, Singapore, Singapore
[8] Sun Yat Sen Univ, Clin Res Ctr, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou, Peoples R China
[9] Univ Melbourne, Royal Victorian Eye & Ear Hosp, Ctr Eye Res Australia, East Melbourne, Australia
关键词
Anterior chamber; SS-OCT; glaucoma; angle closure; imaging; SCLERAL SPUR;
D O I
10.1080/02713683.2021.1942069
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the inter- and intra-observer reliability of anterior chamber (AC) angle measurements obtained by swept-source optical coherence tomography (SS-OCT). Methods: Forty-eight consecutive patients diagnosed with primary angle closure suspect (PACS) were included. Three masked observers at different training levels (one glaucoma specialist, one ophthalmology resident, and one pre-medical college student) measured 192 SS-OCT images of the PACS patients. One observer (the glaucoma specialist) repeated measurements 1 week later. SS-OCT parameters included: Anterior segment volume, including corneal, AC, and iris volume; anterior segment dimensions, including AC depth and width (ACD, ACW), and lens vault (LV); and angle parameters, including angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), and the trabecular iris angle (TIA). Intraclass correlation coefficients (ICCs) were used to measure reliability. Results: For inter-observer reproducibility, ICCs of corneal, AC, and iris volumes were 0.952 to 0.998. ICCs of ACD at all axes were above 0.989. ICCs of ACW and LV were smallest in the 90 degrees-270 degrees axis (0.751 and 0.768) but not significantly different from other axes. ARA, TISA, and TIA at all angles had significantly smallest ICCs 250 mu m from the scleral spur compared with 500 mu m and 750 mu m. The ICCs comparing observers with different training levels had similar ranges and followed similar trends. For intra-observer repeatability, the smallest ICC was 0.843. Decreasing AC depth correlated with increased inter-observer reproducibility. Conclusions: We found excellent intra-observer repeatability for all SS-OCT parameters. Angle measurements have more variation among the observers when taken 250 mu m from the scleral spur. Shallow AC might lead to more variability for angle parameters. Non-expert observers may be recruited for high-quality image grading with standard training.
引用
收藏
页码:1853 / 1860
页数:8
相关论文
共 50 条
  • [21] Assessment of circumferential angle closure with Swept-Source Optical Coherence Tomography: a community based study
    Porporato, Natalia
    Mani, Baskaran
    Ganguly, Rehena Sultana
    Tun, Tin Aung
    Tan, Marcus C. L.
    Quah, Joanne H.
    Nongpiur, Monisha E.
    Allen, John
    Cheng, Ching-Yu
    Aung, Tin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [22] Assessment of Circumferential Angle Closure with Swept-Source Optical Coherence Tomography: a Community Based Study
    Porporato, Natalia
    Baskaran, Mani
    Tun, Tin A.
    Sultana, Rehena
    Tan, Marcus C. L.
    Quah, Joanne H. M.
    Allen, John
    Friedman, David S.
    Cheng, Ching-Yu
    Aung, Tin
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 199 : 133 - 139
  • [23] Evaluation of Anterior Chamber Volume in Cataract Patients with Swept-Source Optical Coherence Tomography
    He, Wenwen
    Zhu, Xiangjia
    Wolff, Don
    Zhao, Zhennan
    Sun, Xinghuai
    Lu, Yi
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [24] Repeatability and Interobserver Reproducibility of a Swept-Source Optical Coherence Tomography for Measurements of Anterior, Posterior, and Total Corneal Power
    Lei, Chak Seng
    Lin, Xuanqiao
    Ning, Rui
    Yu, Jinjin
    Huang, Xiaomin
    Li, Kexin
    Wang, Yiran
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Huang, Jinhai
    OPHTHALMOLOGY AND THERAPY, 2023, 12 (06) : 3263 - 3279
  • [25] Repeatability and Interobserver Reproducibility of a Swept-Source Optical Coherence Tomography for Measurements of Anterior, Posterior, and Total Corneal Power
    Chak Seng Lei
    Xuanqiao Lin
    Rui Ning
    Jinjin Yu
    Xiaomin Huang
    Kexin Li
    Yiran Wang
    Giacomo Savini
    Domenico Schiano-Lomoriello
    Xingtao Zhou
    Jinhai Huang
    Ophthalmology and Therapy, 2023, 12 : 3263 - 3279
  • [26] Correction: Evaluation of Schlemm’s canal with swept-source optical coherence tomography in primary angle-closure disease
    Xuming Ding
    Lulu Huang
    Cheng Peng
    Li Xu
    Yixin Liu
    Yijie Yang
    Ning Wang
    Mengyang Gu
    Chengyang Sun
    Yue Wu
    Wenyi Guo
    BMC Ophthalmology, 23
  • [27] Reproducibility of Anterior Chamber Angle Measurements with Anterior Segment Optical Coherence Tomography
    Tan, Annelie N.
    Sauren, Loes D. C.
    de Brabander, John
    Berendschot, Tos T. J. M.
    Passos, Valeria Lima
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    Beckers, Henny J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) : 2095 - 2099
  • [28] High-speed, swept-source optical coherence tomography: a 3-dimensional view of anterior chamber angle recession
    Kawana, Keisuke
    Yasuno, Yoshiaki
    Yatagai, Toyohiko
    Oshika, Tetsuro
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (06): : 684 - 685
  • [29] Imaging the Iris with Swept Source Optical Coherence Tomography - Impact of Iris Volume Measurement on Primary Angle Closure
    Mak, Heather
    Xu, Guihua
    Leung, Christopher
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [30] Agreement between different levels of expertise for diagnosing angle closure with Swept-Source Optical Coherence Tomography
    Ignacio Perez, Claudio
    Nguyen, Anwell
    Chansangpetch, Sunee
    Mora, Marta
    Badr, Mai
    Porco, Travis
    Lin, Shan C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)