Repeatability and Reproducibility of Anterior Chamber Angle Measurement with Swept-Source Optical Coherence Tomography in Patients with Primary Angle Closure Suspect

被引:3
|
作者
Zhao, Tong [1 ,2 ]
Zhao, Mengya [1 ,3 ]
Xie, Qinghong [1 ]
Fong, Christopher W. [1 ]
Chen, Jeremy [1 ]
Liu, Yingna [1 ]
Feng, Hui [4 ]
Li, Shuning [4 ]
Arnold, Benjamin F. [1 ,5 ]
Aung, Tin [6 ,7 ]
He, Mingguang [8 ,9 ]
Oatts, Julius T. [1 ]
Han, Ying [1 ]
机构
[1] Univ Calif San Francisco, Dept Ophthalmol, 10 Koret Way, San Francisco, CA 94143 USA
[2] China Japan Friendship Hosp, Dept Ophthalmol, Beijing, Peoples R China
[3] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Ophthalmol, Sch Med, Shanghai, Peoples R China
[4] Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China
[5] Univ Calif San Francisco, Francis I Proctor Fdn, San Francisco, CA 94143 USA
[6] Singapore Natl Eye Ctr, Singapore Eye Res Inst, Singapore, Singapore
[7] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Ophthalmol, Singapore, Singapore
[8] Sun Yat Sen Univ, Clin Res Ctr, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou, Peoples R China
[9] Univ Melbourne, Royal Victorian Eye & Ear Hosp, Ctr Eye Res Australia, East Melbourne, Australia
关键词
Anterior chamber; SS-OCT; glaucoma; angle closure; imaging; SCLERAL SPUR;
D O I
10.1080/02713683.2021.1942069
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the inter- and intra-observer reliability of anterior chamber (AC) angle measurements obtained by swept-source optical coherence tomography (SS-OCT). Methods: Forty-eight consecutive patients diagnosed with primary angle closure suspect (PACS) were included. Three masked observers at different training levels (one glaucoma specialist, one ophthalmology resident, and one pre-medical college student) measured 192 SS-OCT images of the PACS patients. One observer (the glaucoma specialist) repeated measurements 1 week later. SS-OCT parameters included: Anterior segment volume, including corneal, AC, and iris volume; anterior segment dimensions, including AC depth and width (ACD, ACW), and lens vault (LV); and angle parameters, including angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), and the trabecular iris angle (TIA). Intraclass correlation coefficients (ICCs) were used to measure reliability. Results: For inter-observer reproducibility, ICCs of corneal, AC, and iris volumes were 0.952 to 0.998. ICCs of ACD at all axes were above 0.989. ICCs of ACW and LV were smallest in the 90 degrees-270 degrees axis (0.751 and 0.768) but not significantly different from other axes. ARA, TISA, and TIA at all angles had significantly smallest ICCs 250 mu m from the scleral spur compared with 500 mu m and 750 mu m. The ICCs comparing observers with different training levels had similar ranges and followed similar trends. For intra-observer repeatability, the smallest ICC was 0.843. Decreasing AC depth correlated with increased inter-observer reproducibility. Conclusions: We found excellent intra-observer repeatability for all SS-OCT parameters. Angle measurements have more variation among the observers when taken 250 mu m from the scleral spur. Shallow AC might lead to more variability for angle parameters. Non-expert observers may be recruited for high-quality image grading with standard training.
引用
收藏
页码:1853 / 1860
页数:8
相关论文
共 50 条
  • [1] Inter- and intra-observer reproducibility of anterior chamber angle measurement with Swept-Source Optical Coherence Tomography in Patients with Primary Angle Closure Suspect
    Zhao, Tong
    Zhao, Mengya
    Xie, Qinghong
    Fong, Christopher
    Chen, Jeremy
    Li, Shuning
    Oatts, Julius T.
    Han, Ying
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [2] Anterior Chamber Angle Imaging with Swept-Source Optical Coherence Tomography: An Investigation on Variability of Angle Measurement
    Liu, Shu
    Yu, Marco
    Ye, Cong
    Lam, Dennis S. C.
    Leung, Christopher Kai-shun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (12) : 8598 - 8603
  • [3] Reproducibility of Anterior Chamber Angle Analyses With the Swept-Source Optical Coherence Tomography in Young, Healthy Caucasians
    Romkens, Hellen C. S.
    Beckers, Henny J. M.
    Frusch, Marc
    Berendschot, Tos T. J. M.
    de Brabander, John
    Webers, Carroll A. B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (06) : 3999 - 4004
  • [4] Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography
    Li, Haitao
    Leung, Christopher Kai Shun
    Cheung, Carol Yim Lui
    Wong, Lee
    Pang, Chi Pui
    Weinreb, Robert Neal
    Lam, Dennis Shun Chiu
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (11) : 1490 - 1492
  • [5] 360-degree measurement of anterior chamber angle dimensions in primary angle closure (PAC) with swept-source optical coherence tomography (SS-OCT)
    Zheng, Feihui
    Leung, Christopher Kai-Shun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [6] Investigation of Anterior Chamber Angle by Swept-Source Polarization Sensitive Optical Coherence Tomography
    Yasuno, Yoshiaki
    Yamanari, Masahiro
    Kawana, Keisuke
    Miura, Masahiro
    Makita, Shuichi
    Oshika, Tetsuro
    OPHTHALMIC TECHNOLOGIES XIX, 2009, 7163
  • [7] Evaluation of the Diagnostic Performance of Swept-Source Anterior Segment Optical Coherence Tomography in Primary Angle Closure Disease
    Ma, Ping
    Wu, Yanyan
    Oatts, Julius
    Patlidanon, Jutima
    Yu, Yinxi
    Ying, Gui-Shuang
    Kline, Brad
    Tun, Tin A.
    He, Mingguang
    Aung, Tin
    Li, Shuning
    Yang, Yangfan
    Han, Ying
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 233 : 68 - 77
  • [8] Comparison of Swept-Source Anterior Segment Ocular Coherence Tomography and Gonioscopy in Detecting Anterior Chamber Angle Closure
    Yaisiri, Panhathai
    Panarojwongse, Natthanose
    Treesit, Isaraporn
    Choontanom, Raveewan
    Jatuthong, Ornwasee
    Iemsomboon, Wallop
    Funarunart, Panrapee
    CLINICAL OPHTHALMOLOGY, 2025, 19 : 699 - 711
  • [9] Anterior Chamber Angle Imaging with Swept-Source Optical Coherence Tomography: Measuring Peripheral Anterior Synechia in Glaucoma
    Lai, Isabel
    Mak, Heather
    Lai, Gilda
    Yu, Marco
    Lam, Dennis S. C.
    Leung, Christopher K. S.
    OPHTHALMOLOGY, 2013, 120 (06) : 1144 - 1149
  • [10] Anterior chamber angle imaging with swept-source optical coherence tomography: comparison between CASIAII and ANTERION
    Poemen Pui-man Chan
    Gilda Lai
    Vivian Chiu
    Anita Chong
    Marco Yu
    Christopher Kai-shun Leung
    Scientific Reports, 10