High temperature tests of cold-formed stainless steel double shear bolted connections

被引:43
|
作者
Cai, Yancheng [1 ]
Young, Ben [1 ]
机构
[1] Univ Hong Kong, Dept Civil Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Double shear bolted connection; Elevated temperatures; Failure modes; Stainless steel; Steady state tests; Transient state tests; THIN SHEET STEELS; ELEVATED-TEMPERATURES; BEHAVIOR; DESIGN; COLUMNS;
D O I
10.1016/j.jcsr.2014.09.015
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
There is currently no design rule on bolted connections of cold-formed stainless steel structures at elevated temperatures. In this study, a total of 194 double shear bolted connection specimens with three different grades of stainless steel were tested, where 106 specimens were tested by steady state test method and 88 specimens were tested by transient state test method. The three different grades of stainless steel are austenitic stainless steel EN 1.4301 (AISI 304) and EN 1.4571 (AISI 316Ti having small amount of titanium) as well as lean duplex stainless steel EN 1.4162 (AISI S32101). The connections were designed with different bolt diameters, number of bolts and arrangement of the bolts. Bearing failure and net section tension failure modes were observed in the double shear bolted connection tests. The test results were compared with the nominal strengths calculated from the design rules in the American Specification, Australian/New Zealand Standard and European Codes for stainless steel structures. In calculating the nominal strengths of the connections, the material properties at elevated temperatures were used in the design equations for room temperature. It is shown that the strengths of the cold-formed stainless steel double shear bolted connections obtained from the specifications are generally conservative at elevated temperatures. The connection strengths decrease as the temperature increases in the similar manner for the steady state tests and the transient state tests as well as the material coupon tests. It is also found that the austenitic stainless steel type EN 1.4571 generally has better resistance than the stainless steel types EN 1.4301 and EN 1.4162 for double shear bolted connections at elevated temperatures. (C) 2014 Elsevier Ltd. All sights reserved.
引用
收藏
页码:49 / 63
页数:15
相关论文
共 50 条
  • [21] Bearing strength of cold-formed steel bolted connections with a gap
    Yu, Cheng
    Panyanouvong, Mark Xouphab
    THIN-WALLED STRUCTURES, 2013, 67 : 110 - 115
  • [22] Serviceability limit state for cold-formed steel bolted connections
    LaBoube, RA
    Yu, WW
    Carril, JL
    CONNECTIONS IN STEEL STRUCTURES III: BEHAVIOUR, STRENGTH AND DESIGN, 1996, : 403 - 411
  • [23] New design provisions for cold-formed steel bolted connections
    LaBoube, RA
    Yu, WW
    LIGHT-WEIGHT STEEL AND ALUMINIUM STRUCTURES, 1999, : 569 - 576
  • [24] Structural performance of cold-formed steel structures with bolted connections
    Chung, KF
    ADVANCES IN STRUCTURAL ENGINEERING, 2005, 8 (03) : 231 - 245
  • [25] BEHAVIOUR AND CAPACITY OF COLD-FORMED STEEL BOLTED MOMENT CONNECTIONS
    Mojtabaei, Seyed Mohammad
    Becque, Jurgen
    Hajirasouliha, Iman
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 628 - 638
  • [26] Structural behaviour of cold-formed stainless steel bolted connections at post-fire condition
    Cai, Yancheng
    Young, Ben
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 152 : 312 - 321
  • [27] A PARAMETRIC STUDY ON BEARING STRENGTHS OF COLD-FORMED STAINLESS STEEL BOLTED CONNECTIONS AT ELEVATED TEMPERATURES
    Cai, Yancheng
    Young, Ben
    STEEL AND ALUMINIUM STRUCTURES, 2016,
  • [28] Finite element modelling of double bolted connections between cold-formed steel strips under static shear loading
    Chung, KF
    Ip, KH
    ADVANCES IN STEEL STRUCTURES, VOLS 1 AND 2, 1999, : 245 - 252
  • [29] Tests of bolted and internal sleeve knee connections in cold-formed RHS
    Wilkinson, T
    Hancock, GJ
    TUBULAR STRUCTURES VIII, 1998, : 187 - 195
  • [30] Tests of cold-formed high strength stainless steel compression members
    Young, B
    Lui, WM
    THIN-WALLED STRUCTURES, 2006, 44 (02) : 224 - 234