Tests of bolted and internal sleeve knee connections in cold-formed RHS

被引:0
|
作者
Wilkinson, T [1 ]
Hancock, GJ [1 ]
机构
[1] Univ Sydney, Dept Civil Engn, Ctr Adv Struct Engn, Sydney, NSW 2006, Australia
来源
关键词
cold-formed steel; hollow sections; welded connections; bolted connections; joints; plastic design; bending; rotation capacity; local buckling; heat affected zone; fracture; internal sleeve;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper examines different knee connections for portal frames constructed from cold-formed rectangular hollow sections: bolted plate connections, and welded and bolted internal sleeve connections. The specimen joints were tested in both tension and compression (opening and closing moments) to simulate wind uplift or gravity loading. It wits found that the sleeve connections were capable of sustaining the plastic moment for large rotations considered suitable for plastic design. The use of an internal sleeve moved the plastic hinge in the connection away from the connection centreline and reduced the stress on the weld between the RHS. However, at present, the sleeve connection may not be a commercially viable possibility. The bolted plate connection achieved plastic rotations but failed in the heat affected zone in tension.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 50 条
  • [1] Tests of stiffened and unstiffened welded knee connections in cold-formed RHS
    Wilkinson, T
    Hancock, GJ
    TUBULAR STRUCTURES VIII, 1998, : 177 - 186
  • [2] Tests to examine plastic behavior of knee joints in cold-formed RHS
    Wilkinson, T
    Hancock, GJ
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2000, 126 (03): : 297 - 305
  • [3] Tests of portal frames in cold-formed RHS
    Wilkinson, T
    Hancock, GJ
    TUBULAR STRUCTURES VIII, 1998, : 521 - 529
  • [4] The capacity of bolted cold-formed steel connections in bending
    Mojtabaei, S. M.
    Becque, J.
    Hajirasouliha, I
    STABILITY AND DUCTILITY OF STEEL STRUCTURES 2019, 2019, : 830 - 838
  • [5] Countersunk bolted moment connections in cold-formed steel
    Becque, J.
    Hajirasouliha, I
    INSIGHTS AND INNOVATIONS IN STRUCTURAL ENGINEERING, MECHANICS AND COMPUTATION, 2016, : 1074 - 1079
  • [6] Transient state tests of cold-formed stainless steel single shear bolted connections
    Cai, Yancheng
    Young, Ben
    ENGINEERING STRUCTURES, 2014, 81 : 1 - 9
  • [7] High temperature tests of cold-formed stainless steel double shear bolted connections
    Cai, Yancheng
    Young, Ben
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 104 : 49 - 63
  • [8] Analysis of cold-formed purlins with slotted sleeve connections
    Gutierrez, R.
    Loureiro, A.
    Lopez, M.
    Moreno, A.
    THIN-WALLED STRUCTURES, 2011, 49 (07) : 833 - 841
  • [9] Comparison of analysis with tests of cold-formed RHS portal frames
    Wilkinson, T
    Hancock, GJ
    MECHANICS OF STRUCTURES AND MATERIALS, 1999, : 245 - 250
  • [10] Sleeve connections of cold-formed steel sigma purlins
    Yang, Jian
    Liu, Qiang
    ENGINEERING STRUCTURES, 2012, 43 : 245 - 258