A novel poly(cyanocobalamin) modified glassy carbon electrode as electrochemical sensor for voltammetric determination of peroxynitrite

被引:27
|
作者
Wang, Yan [1 ]
Chen, Zhen-zhen [1 ]
机构
[1] Shandong Normal Univ, Coll Chem Chem Engn & Mat Sci, Jinan 250014, Peoples R China
关键词
Peroxynitrite; Cyanocobalamin; Chemical modified electrode; Differential pulse voltammetry; NITRIC-OXIDE; OXIDATION; VITAMIN-B-12; COBALT; ELECTROOXIDATION; SUPEROXIDE; REDUCTION; CATALYSIS; MANGANESE;
D O I
10.1016/j.talanta.2010.05.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This report described the direct voltammetric detection of peroxynitrite (ONOO-) at a novel cyanocobalamin modified glassy carbon electrode prepared by electropolymeriation method. The electrochemical behaviors of peroxynitrite at the modified electrode were studied by cyclic voltammetry. The results showed that this new electrochemical sensor exhibited an excellent electrocatalytic activity to oxidation of peroxynitrite. The mechanism of catalysis was discussed. Based on electrocatalytic oxidation of peroxynitrite at the poly(cyanocobalamin) modified electrode, peroxynitrite was sensitively detected by differential pulse voltammetry. Under optimum conditions, the anodic peak current was linear to concentration of peroxynitrite in the range of 2.0 x 10(-6) to 3.0 x 10(-4) mol L-1 with a detection limit of 1.0 x 10(-7) mol L-1 (S/N of 3). The proposed method has been applied to determination of peroxynitrite in human serum with satisfactory results. This poly(cyanocobalamin) modified electrode showed high selectivity and sensitivity to peroxynitrite determination, which could be used in quantitative detection of peroxynitrite in vivo and in vitro. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:534 / 539
页数:6
相关论文
共 50 条
  • [21] Electrochemical sensor based on phospholipid modified glassy carbon electrode - determination of paraquat
    Tomkova, H.
    Sokolova, R.
    Opletal, T.
    Kucerova, P.
    Kucera, L.
    Souckova, J.
    Skopalova, J.
    Bartak, P.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 821 : 33 - 39
  • [22] Graphene Ink Modified Glassy Carbon Electrode as electrochemical sensor for Galantamine Determination
    Shi, Haobin
    Zheng, Yuhong
    Wu, Mengyao
    Fu, Li
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (02): : 1546 - 1555
  • [23] Voltammetric determination of florfenicol by using poly(3-methylthiophene) modified glassy carbon electrode
    Taskin, Imren
    Gungor, Oznur
    Titretir Duran, Serap
    POLYMER BULLETIN, 2021, 78 (08) : 4721 - 4741
  • [24] Voltammetric determination of florfenicol by using poly(3-methylthiophene) modified glassy carbon electrode
    İmren Taşkın
    Öznur Güngör
    Serap Titretir Duran
    Polymer Bulletin, 2021, 78 : 4721 - 4741
  • [25] Voltammetric determination of adrenaline using a poly(1-methylpyrrole) modified glassy carbon electrode
    Aslanoglu, Mehmet
    Kutluay, Aysegul
    Karabulut, Serpil
    Abbasoglu, Sultan
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2008, 55 (04) : 794 - 800
  • [26] Voltammetric Determination of Paracetamol with Poly(3,4-Ethylenedioxythiophene) Modified Glassy Carbon Electrode
    Mehretie, Solomon
    Admassie, Shimelis
    Tessema, Merid
    Solomon, Theodros
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2011, 3 (01): : 38 - 50
  • [27] Voltammetric Determination of Sumatriptan by an Overoxidized Poly(p-aminophenol) Modified Glassy Carbon Electrode
    Jalali-Sarvestani, Mohammad Reza
    Madrakian, Tayyebeh
    Afkhami, Abbas
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2021, 8 (03): : 245 - 259
  • [28] Voltammetric sensor based on cobalt-poly(methionine)-modified glassy carbon electrode for determination of estriol hormone in pharmaceuticals and urine
    Gomes, Eliziana S.
    Leite, Fernando R. F.
    Ferraz, Bruno R. L.
    Mourao, Henrique A. J. L.
    Malagutti, Andrea R.
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2019, 9 (05) : 347 - 357
  • [29] Voltammetric sensor based on cobalt-poly(methionine)-modified glassy carbon electrode for determination of estriol hormone in pharmaceuticals and urine
    Eliziana S.Gomes
    Fernando R.F.Leite
    Bruno R.L.Ferraz
    Henrique A.J.L.Mourao
    Andréa R.Malagutti
    JournalofPharmaceuticalAnalysis, 2019, 9 (05) : 347 - 357
  • [30] Nickelhexacyanoferrate-Modified Glassy Carbon Electrode as a Voltammetric and Electrochemical Impedance Spectroscopic Sensor for Thiocyanate Ion
    Deka, Kangkana
    Das, Diganta K.
    CHEMISTRYSELECT, 2018, 3 (02): : 481 - 485