Surrogate based continuous noninvasive blood pressure measurement

被引:7
|
作者
Pielmus, Alexandru-Gabriel [1 ]
Muehlstef, Jens [2 ]
Bresch, Erik [2 ]
Glos, Martin [3 ]
Jungen, Christiane [4 ]
Mieke, Stefan [5 ]
Orglmeister, Reinhold [1 ]
Schulze, Andreas [2 ]
Stender, Birgit [6 ]
Voigt, Verena [7 ]
Zaunseder, Sebastian [8 ,9 ]
机构
[1] Tech Univ Berlin, Elect & Med Signal Proc, Einsteinufer 17, D-10587 Berlin, Germany
[2] Philips Res Europe, Res Grp Patient Care Solut, Eindhoven, Netherlands
[3] Charite Univ Med Berlin, Interdisciplinary Ctr Sleep Med, Berlin, Germany
[4] Univ Herz & Gefasszentrum UKE Hamburg, Klin & Poliklin Kardiol, Hamburg, Germany
[5] Phys Tech Bundesanstalt, Berlin, Germany
[6] Dragerwerk AG & Co KgaA, Lubeck, Germany
[7] Uniklin RWTH Aachen, Sekt Med Tech, Klin Anasthesiol, Aachen, Germany
[8] Tech Univ Dresden, Dresden, Germany
[9] Fachhsch Dortmund, Dortmund, Germany
来源
关键词
clinical; expert; guideline; NIBP; recommendation; workshop; PULSE TRANSIT-TIME; VELOCITY; VALIDATION;
D O I
10.1515/bmt-2020-0209
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Arterial blood pressure is one of the most often measured vital parameters in clinical practice. State-of-the-art noninvasive ABP measurement technologies have noticeable limitations and are mainly based on uncomfortable techniques of complete or partial arterial occlusion by cuffs. Most commonplace devices provide only intermittent measurements, and continuous systems are bulky and difficult to apply correctly for nonprofessionals. Continuous cuffless ABP measurements are still an unmet clinical need and a topic of ongoing research, with only few commercially available devices. This paper discusses surrogate-based noninvasive blood pressure measurement techniques. It covers measurement methods of continuously and noninvasively inferring BP from surrogate signals without applying external pressures, except for reference or initialization purposes. The BP is estimated by processing signal features, so called surrogates, which are modulated by variations of BP. Discussed techniques include well-known approaches such as pulse transit time and pulse arrival time techniques, pulse wave analysis or combinations thereof. Despite a long research history, these methods have not found widespread use in clinical and ambulatory practice, in part due to technical limitations and the lack of a standardized regulatory framework. This work summarizes findings from an invited workshop of experts in the fields covering clinical expertise, engineering aspects, commercialization and standardization issues. The goal is to provide an application driven outlook, starting with clinical needs, and extending to technical actuality. It provides an outline of recommended research directions and includes a detailed overview of clinical use case scenarios for these technologies, opportunities, and limitations.
引用
收藏
页码:231 / 245
页数:15
相关论文
共 50 条
  • [41] Noninvasive blood pressure measurement in patients with continuous-flow left ventricular assist devices
    Aiko Tanaka
    Yuki Kiriyama
    Naoko Kubo
    Ryota Sakaguchi
    Akinori Uchiyama
    Yuji Fujino
    Journal of Artificial Organs, 2023, 26 : 160 - 164
  • [42] NONINVASIVE MEASUREMENT OF BAROREFLEX SENSITIVITY INDEX USING AN INDIRECT AND CONTINUOUS BLOOD-PRESSURE RECORDER
    TOCHIKUBO, O
    KANEKO, Y
    YUKINARI, Y
    TAKEDA, I
    JAPANESE HEART JOURNAL, 1986, 27 (06): : 849 - 857
  • [43] Continuous and Noninvasive Blood Pressure Estimation by Two-Sensor Measurement of Pulse Transit Time
    Rasool, Anam
    Rafiq, Muqudas
    Nasir, Aisha
    Kashif, Faisal M.
    2018 14TH INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES (ICET), 2018,
  • [44] Noninvasive blood pressure measurement in patients with continuous-flow left ventricular assist devices
    Tanaka, Aiko
    Kiriyama, Yuki
    Kubo, Naoko
    Sakaguchi, Ryota
    Uchiyama, Akinori
    Fujino, Yuji
    JOURNAL OF ARTIFICIAL ORGANS, 2023, 26 (02) : 160 - 164
  • [45] COMPARISON OF INTRAARTERIAL WITH CONTINUOUS NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN POSTOPERATIVE PEDIATRIC-PATIENTS
    TRIEDMAN, JK
    SAUL, JP
    JOURNAL OF CLINICAL MONITORING, 1994, 10 (01): : 11 - 20
  • [46] Resonance sonomanometry for noninvasive, continuous monitoring of blood pressure
    Jimenez, Raymond
    Yurk, Dominic
    Dell, Steven
    Rutledge, Austin C.
    Fu, Matt K.
    Dempsey, William P.
    Abu-Mostafa, Yaser
    Rajagopal, Aditya
    Brinley Rajagopal, Alaina
    PNAS NEXUS, 2024, 3 (07):
  • [47] EVALUATION OF A CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITOR
    ABENSTEIN, JP
    STENSRUD, PE
    SPACKMAN, TN
    TARHAN, S
    ANESTHESIOLOGY, 1993, 79 (3A) : A504 - A504
  • [48] Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®
    Martina, Jerson R.
    Westerhof, Berend E.
    van Goudoever, Jeroen
    de Beaumont, Edouard M. F. H.
    Truijen, Jasper
    Kim, Yu-Sok
    Immink, Rogier V.
    Jobsis, Dorothea A.
    Hollmann, Markus W.
    Lahpor, Jaap R.
    de Mol, Bas A. J. M.
    van Lieshout, Johannes J.
    ANESTHESIOLOGY, 2012, 116 (05) : 1092 - 1103
  • [49] Continuous blood pressure measurement based on carotid artery diameter
    Li, H. Y.
    Li, Y. B.
    Li, S. L.
    Deng, N.
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING: NEW ADVANCES, 2016, : 61 - 66
  • [50] Continuous blood pressure measurement system based on low cuff pressure approach
    Ding, Cang-Yi
    Huang, Cheng-Ning
    Yu, Fang-Ming
    Chung, Hung-Yuan
    PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-8, 2007, : 776 - +