MULTIDIMENSIONAL ULTRASOUND DOPPLER SIGNAL ANALYSIS FOR FETAL ACTIVITY MONITORING

被引:4
|
作者
Ribes, Sophie [1 ]
Girault, Jean-Marc [2 ]
Perrotin, Franck [3 ]
Kouame, Denis [1 ]
机构
[1] Univ Toulouse 3, CNRS, IRIT, UMR 5505, F-31062 Toulouse, France
[2] Univ Tours, INSERM, U930, Tours, France
[3] INSERM, CHU Bretonneau, U930, Tours Serv Gynecol Obstet, Tours, France
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2015年 / 41卷 / 12期
关键词
Fetal monitoring; Fetal heart rhythm; Fetal movement; Multidimensional signals; Support vector machine; HEART-RATE; SYSTEM;
D O I
10.1016/j.ultrasmedbio.2015.07.026
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Fetal activity parameters such as movements, heart rate and the related parameters are essential indicators of fetal wellbeing, and no device provides simultaneous access to and sufficient estimation of all of these parameters to evaluate fetal health. This work was aimed at collecting these parameters to automatically separate healthy from compromised fetuses. To achieve this goal, we first developed a multi-sensor-multi-gate Doppler system. Then we recorded multidimensional Doppler signals and estimated the fetal activity parameters via dedicated signal processing techniques. Finally, we combined these parameters into four sets of parameters (or four hyperparameters) to determine the set of parameters that is able to separate healthy from other fetuses. To validate our system, a data set consisting of two groups of fetal signals (normal and compromised) was established and provided by physicians. From the estimated parameters, an instantaneous Manning-like score, referred to as the ultrasonic score, was calculated and was used together with movements, heart rate and the associated parameters in a classification process employing the support vector machine method. We investigated the influence of the sets of parameters and evaluated the performance of the support vector machine using the computation of sensibility, specificity, percentage of support vectors and total classification error. The sensitivity of the four sets ranged from 79% to 100%. Specificity was 100% for all sets. The total classification error ranged from 0% to 20%. The percentage of support vectors ranged from 33% to 49%. Overall, the best results were obtained with the set of parameters consisting of fetal movement, short-term variability, long-term variability, deceleration and ultrasound score. The sensitivity, specificity, percentage of support vectors and total classification error of this set were respectively 100%, 100%, 35% and 0%. This indicated our ability to separate the data into two sets (normal fetuses and pathologic fetuses), and the results highlight the excellent match with the clinical classification performed by the physicians. This work indicates the feasibility of detecting compromised fetuses and also represents an interesting method of close fetal monitoring during the entire pregnancy. (C) 2015 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:3172 / 3181
页数:10
相关论文
共 50 条
  • [31] Displacement vector measurement using instantaneous ultrasound signal phase - Multidimensional autocorrelation and Doppler methods
    Sumi, Chikayoshi
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (01) : 24 - 43
  • [32] The performance and reliability of Wavelet Denoising for Doppler ultrasound Fetal Heart Rate signal preprocessing
    Papadimitriou, S
    Papadopoulos, V
    Gatzounas, D
    Tzigounis, V
    Bezerianos, A
    MEDICAL INFORMATICS EUROPE '97: PARTS A & B, 1997, 43 : 561 - 565
  • [33] Reducing Influence of Doppler Ultrasound Signal Processing Techniques on Fetal Heart Rate Variability
    Wrobel, Janusz
    Jezewski, Janusz
    Roj, Dawid
    Przybyla, Tomasz
    Matonia, Adam
    SELECTED TOPICS IN APPLIED COMPUTER SCIENCE, 2010, : 128 - 133
  • [34] Doppler Ultrasound Signal in Achilles Tendinopathy Reduces Immediately After Activity
    Malliaras, P.
    Chan, O.
    Simran, G.
    Martinez de Albornoz, P.
    Morrissey, D.
    Maffulli, N.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2012, 33 (06) : 480 - 484
  • [35] A Robust Approach Assisted by Signal Quality Assessment for Fetal Heart Rate Estimation from Doppler Ultrasound Signal
    Shi, Xintong
    Niida, Natsuho
    Yamamoto, Kohei
    Ohtsuki, Tomoaki
    Matsui, Yutaka
    Owada, Kazunari
    Affanni, Antonio
    Zontone, Pamela
    SENSORS, 2023, 23 (24)
  • [36] DOPPLER ULTRASOUND VELOCIMETRY FOR FETAL SURVEILLANCE
    MAULIK, D
    CLINICAL OBSTETRICS AND GYNECOLOGY, 1995, 38 (01): : 91 - 111
  • [37] Algorithm for Signal Processing of Fetal Activity in the Remote Monitoring System
    Bobrova, Yulia O.
    PROCEEDINGS OF THE 2019 IEEE CONFERENCE OF RUSSIAN YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING (EICONRUS), 2019, : 1263 - 1265
  • [38] DOPPLER ULTRASOUND MONITORING TECHNOLOGY
    DOCKER, MF
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1993, 100 : 18 - 20
  • [39] Cardiotocography and beyond: a review of one-dimensional Doppler ultrasound application in fetal monitoring
    Marzbanrad, Faezeh
    Stroux, Lisa
    Clifford, Gari D.
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (08)
  • [40] Color doppler ultrasound combined with fetal heart rate monitoring in fetal distress and its correlation with pregnancy outcomes
    Ding, Xiuju
    Ge, Min
    Li, Mengling
    Dai, Peifeng
    Lang, Yan
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2020, 127 : 91 - 91