A sheath-flow nanospray interface for capillary electrophoresis/mass spectrometry

被引:45
|
作者
Liu, CC
Zhang, JZ
Dovichi, NJ
机构
[1] Appl Biosyst Inc, Foster City, CA 94404 USA
[2] Beckman Coulter Inc, Fullerton, CA 92834 USA
[3] Univ Washington, Dept Chem, Seattle, WA 98185 USA
关键词
D O I
10.1002/rcm.1769
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have developed a novel sheath-flow interface for low-flow electrospray ionization mass spectrometry (ESI-MS) and capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The interface is composed of two capillaries. One is a tapered fused-silica ESI emitter suitable for microliter and nanoliter flow rate electrospray and the other is a tail-end gold-coated CE separation column that is inserted into the emitter. A sheath liquid is supplied between the column and the emitter capillaries. The gold coating and the sheath liquid are used as the conducting media for ESI and the CE circuit. This novel design was initially evaluated by an infusion ESI-MS analysis of the most common antiretroviral dideoxynucleosides, followed by CE/MS coupling analysis of several antidepressant drugs. With infusion studies, the effects of the sheath liquid and the sample flow rates on detection sensitivity and signal stability were investigated. For an emitter with an internal diameter of 30 mum, the optimum flow rates for the sheath and the sample were 200 and 300 nL/min, respectively. The main improvement of this approach in comparison with conventional sheath liquid approaches using an ionspray interface is the gain in sensitivity. Sensitivities were three times better for dideoxynucleosides analyzed by infusion and 12 times higher for antidepressant drugs analyzed by CEMS with this interface compared with ionspray. The emitter is durable, disposable, and simple to fabricate. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 50 条
  • [31] Chip-based capillary electrophoresis with an electrodeless nanospray interface
    Vrouwe, EX
    Gysler, J
    Tjaden, UR
    van der Greef, J
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (18) : 1682 - 1688
  • [32] Sheath-flow cuvette for high-sensitivity laser-induced fluorescence detection in capillary electrophoresis
    Sobhani, Kimia
    Michels, David A.
    Dovichi, Norman J.
    APPLIED SPECTROSCOPY, 2007, 61 (07) : 777 - 779
  • [33] Capillary electrophoresis to mass spectrometry interface using a porous junction
    Whitt, JT
    Moini, M
    ANALYTICAL CHEMISTRY, 2003, 75 (09) : 2188 - 2191
  • [34] Capillary electrophoresis - Mass spectrometry
    不详
    SPECTROSCOPY, 2003, : 40 - 40
  • [35] Capillary electrophoresis mass spectrometry
    Smith, RD
    Udseth, HR
    Wahl, JH
    Goodlett, DR
    Hofstadler, SA
    HIGH RESOLUTION SEPARATION AND ANALYSIS OF BIOLOGICAL MACROMOLECULES, PT B: APPLICATIONS, 1996, 271 : 448 - 486
  • [36] CAPILLARY ELECTROPHORESIS/MASS SPECTROMETRY
    SMITH, RD
    WAHL, JH
    GOODLETT, DR
    HOFSTADLER, SA
    ANALYTICAL CHEMISTRY, 1993, 65 (13) : A574 - A584
  • [37] Evaluation of a new low sheath-flow interface for CE-MS
    Gonzalez-Ruiz, Victor
    Codesido, Santiago
    Far, Johann
    Rudaz, Serge
    Schappler, Julie
    ELECTROPHORESIS, 2016, 37 (7-8) : 936 - 946
  • [38] Analysis of catecholamines by capillary electrophoresis and capillary electrophoresis-nanospray mass spectrometry -: Use of aqueous and non-aqueous solutions compared with physical parameters
    Vuorensola, K
    Sirén, H
    Kostiainen, R
    Kotiaho, T
    JOURNAL OF CHROMATOGRAPHY A, 2002, 979 (1-2) : 179 - 189
  • [39] Sheathless interface to match flow rate of capillary electrophoresis with electrospray mass spectrometry using regular-sized capillary
    Yin, Yue
    Li, Gongyu
    Guan, Yafeng
    Huang, Guangming
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 : 68 - 72
  • [40] Characterization of a capillary zone electrophoresis electrospray-mass spectrometry interface
    Siethoff, C
    Nigge, W
    Linscheid, M
    ANALYTICAL CHEMISTRY, 1998, 70 (07) : 1357 - 1361