A sheath-flow nanospray interface for capillary electrophoresis/mass spectrometry

被引:45
|
作者
Liu, CC
Zhang, JZ
Dovichi, NJ
机构
[1] Appl Biosyst Inc, Foster City, CA 94404 USA
[2] Beckman Coulter Inc, Fullerton, CA 92834 USA
[3] Univ Washington, Dept Chem, Seattle, WA 98185 USA
关键词
D O I
10.1002/rcm.1769
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have developed a novel sheath-flow interface for low-flow electrospray ionization mass spectrometry (ESI-MS) and capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The interface is composed of two capillaries. One is a tapered fused-silica ESI emitter suitable for microliter and nanoliter flow rate electrospray and the other is a tail-end gold-coated CE separation column that is inserted into the emitter. A sheath liquid is supplied between the column and the emitter capillaries. The gold coating and the sheath liquid are used as the conducting media for ESI and the CE circuit. This novel design was initially evaluated by an infusion ESI-MS analysis of the most common antiretroviral dideoxynucleosides, followed by CE/MS coupling analysis of several antidepressant drugs. With infusion studies, the effects of the sheath liquid and the sample flow rates on detection sensitivity and signal stability were investigated. For an emitter with an internal diameter of 30 mum, the optimum flow rates for the sheath and the sample were 200 and 300 nL/min, respectively. The main improvement of this approach in comparison with conventional sheath liquid approaches using an ionspray interface is the gain in sensitivity. Sensitivities were three times better for dideoxynucleosides analyzed by infusion and 12 times higher for antidepressant drugs analyzed by CEMS with this interface compared with ionspray. The emitter is durable, disposable, and simple to fabricate. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 50 条
  • [21] Two capillary approach for a multifunctional nanoflow sheath liquid interface for capillary electrophoresis-mass spectrometry
    Hoecker, Oliver
    Knierman, Mike
    Meixner, Jens
    Neusuess, Christian
    ELECTROPHORESIS, 2021, 42 (04) : 369 - 373
  • [22] Development and Application of Capillary Electrophoresis-Electrospray Ionization Mass Spectrometry System Based on A Coaxial Sheath Flow Interface
    Zhu, Liu
    Zhang, Nai-Qian
    Fang, Pan
    Pan, Jian-Zhang
    Wong, Catherine
    Fang, Qun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (01) : 34 - 41
  • [23] Sheath-flow electrochemical detection of amino acids with a copper wire electrode in capillary electrophoresis
    Inoue, Junji
    Kaneta, Takashi
    Imasaka, Totaro
    ELECTROPHORESIS, 2012, 33 (17) : 2743 - 2747
  • [24] Interface-free capillary electrophoresis-mass spectrometry system with nanospray ionization Analysis of dexrazoxane in blood plasma
    Tycova, Anna
    Vido, Marek
    Kovarikova, Petra
    Foret, Frantisek
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1466 : 173 - 179
  • [25] CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY DETERMINATION OF INORGANIC-IONS USING AN ION SPRAY-SHEATH FLOW INTERFACE
    HUGGINS, TG
    HENION, JD
    ELECTROPHORESIS, 1993, 14 (5-6) : 531 - 539
  • [26] MULTIPLE SHEATH-FLOW GEL CAPILLARY-ARRAY ELECTROPHORESIS FOR MULTICOLOR FLUORESCENT DNA DETECTION
    TAKAHASHI, S
    MURAKAMI, K
    ANAZAWA, T
    KAMBARA, H
    ANALYTICAL CHEMISTRY, 1994, 66 (07) : 1021 - 1026
  • [27] A sonic spray interface for capillary electrophoresis mass spectrometry
    Hirabayashi, Y
    Hirabayashi, A
    Koizumi, H
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (08) : 712 - 715
  • [28] Hyphenation of capillary high-performance ion-exchange chromatography with mass spectrometry using sheath-flow electrospray ionization
    Kochmann, Sven
    Matysik, Frank-Michael
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (23) : 2670 - 2680
  • [29] A beveled tip sheath liquid interface for capillary electrophoresis-electrospray ionization-mass spectrometry
    Tseng, MC
    Chen, YR
    Her, GR
    ELECTROPHORESIS, 2004, 25 (13) : 2084 - 2089
  • [30] Detection of 1 zmol injection of angiotensin using capillary zone electrophoresis coupled to a Q-Exactive HF mass spectrometer with an electrokinetically pumped sheath-flow electrospray interface
    Amenson-Lamar, Emily Ann
    Sun, Liangliang
    Zhang, Zhenbin
    Bohn, Paul W.
    Dovichi, Norman J.
    TALANTA, 2019, 204 : 70 - 73