Displacement of the epiglottis during intubation with the Pentax-AWS Airway Scope

被引:5
|
作者
Suzuki, Akihiro [1 ]
Katsumi, Norifumi [1 ]
Honda, Takashi [1 ]
Sasakawa, Tomoki [1 ]
Kunisawa, Takayuki [1 ]
Henderson, John J. [2 ]
Iwasaki, Hiroshi [1 ]
机构
[1] Asahikawa Med Coll, Dept Anesthesiol & Crit Care Med, Asahikawa, Hokkaido 0788510, Japan
[2] Gartnavel Royal Hosp, Dept Anaesthesia, Glasgow, Lanark, Scotland
关键词
Pentax-AWS; Airway Scope; Folding epiglottis; Epiglottis displacement; TRACHEAL INTUBATION; LARYNGOSCOPE;
D O I
10.1007/s00540-009-0826-4
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The Pentax-AWS system is a rigid indirect video laryngoscope with integrated tube guidance. Complications associated with this device are not well understood. We report two cases of epiglottis malposition during intubation with the Pentax-AWS. The standard technique of using the Pentax-AWS system involves direct elevation of the epiglottis for exposure of the vocal cords. The blade tip should be passed posterior to the epiglottis for laryngeal exposure, but pressure on the anterior surface of the epiglottis by the tip can rarely happen even during the correct maneuver. Although the Pentax-AWS provides clear images of the airway structures, it is sometimes difficult to observe the epiglottis continuously because the camera is located beneath the blade tip. Consequently, the view of the epiglottis from the camera may be impeded by the blade tip and may result in undiagnosed epiglottis malposition. The AWS's structural feature and its approach to the larynx can be associated with increased chance of unexpected epiglottis folding. It is particularly important to confirm normal position of the epiglottis during withdrawal of the device to prevent this complication.
引用
收藏
页码:124 / 127
页数:4
相关论文
共 50 条
  • [31] Pentax-AWS® and tube selection
    Suzuki, Akihiro
    Kunisawa, Takayuki
    Iwasaki, Hiroshi
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (09): : 773 - 774
  • [32] The PENTAX-AWS (R) video laryngoscope, an alternative to intubation with fibrobronchoscopy in the awake patientwith known difficult airway
    Vila Barriuso, E.
    Chavero Estelrich, E.
    Arroyo Perez, R.
    Salazar Silva, Y.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2013, 60 (08): : 477 - 478
  • [33] Comparison of Pentax-AWS®, Glidescope®, and King Vision® for difficult-airway intubation in manikins model by paramedics
    Lee, Sanghyun
    Kang, Hyunggoo
    Oh, Jaehoon
    Lim, Tae Ho
    Lee, Yoonjae
    Kim, Changsun
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2017, 24 (05) : 237 - 243
  • [34] The Pentax-AWS is particularly suitable for facilitating intubation in edentulous geriatric patients
    Kunihiko Yamamoto
    Akihiro Suzuki
    Yuki Toyama
    Tomoki Sasakawa
    Takayuki Kunisawa
    Osamu Takahata
    Hiroshi Iwasaki
    Journal of Anesthesia, 2009, 23 : 471 - 471
  • [35] The Pentax-AWS is particularly suitable for facilitating intubation in edentulous geriatric patients
    Yamamoto, Kunihiko
    Suzuki, Akihiro
    Toyama, Yuki
    Sasakawa, Tomoki
    Kunisawa, Takayuki
    Takahata, Osamu
    Iwasaki, Hiroshi
    JOURNAL OF ANESTHESIA, 2009, 23 (03) : 471 - 471
  • [36] Pentax-AWS videolaryngoscope for awake nasal intubation in patients with unstable necks
    Asai, T.
    BRITISH JOURNAL OF ANAESTHESIA, 2010, 104 (01) : 108 - 111
  • [37] Awake intubation with the Pentax Airway Scope
    Jarvi, K.
    Hillermann, C.
    Danha, R.
    Mendonca, C.
    ANAESTHESIA, 2011, 66 (04) : 314 - 314
  • [38] Comparison of Pentax-AWS with Macintosh laryngoscope for tracheal intubation in simulated difficult airways
    Xue, Fu-Shan
    Yuan, Yu-Jing
    Wang, Qiang
    Xiong, Jun
    Liao, Xu
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2011, 29 (01): : 120 - 121
  • [39] Tips for intubation with the Pentax-AWS® Rigid Indirect Laryngoscope in morbidly obese patients
    Suzuki, A.
    Terao, M.
    Fujita, S.
    Henderson, J. J.
    ANAESTHESIA, 2008, 63 (04) : 442 - 444
  • [40] Utility of the Pentax-AWS® without interruption of chest compression: Comparison of the Macintosh laryngoscope with the Pentax-AWS® in manikin model
    Han, Sang Kuk
    Shin, Dong Hyuk
    Choi, Pil Cho
    RESUSCITATION, 2010, 81 (01) : 69 - 73