Displacement of the epiglottis during intubation with the Pentax-AWS Airway Scope

被引:5
|
作者
Suzuki, Akihiro [1 ]
Katsumi, Norifumi [1 ]
Honda, Takashi [1 ]
Sasakawa, Tomoki [1 ]
Kunisawa, Takayuki [1 ]
Henderson, John J. [2 ]
Iwasaki, Hiroshi [1 ]
机构
[1] Asahikawa Med Coll, Dept Anesthesiol & Crit Care Med, Asahikawa, Hokkaido 0788510, Japan
[2] Gartnavel Royal Hosp, Dept Anaesthesia, Glasgow, Lanark, Scotland
关键词
Pentax-AWS; Airway Scope; Folding epiglottis; Epiglottis displacement; TRACHEAL INTUBATION; LARYNGOSCOPE;
D O I
10.1007/s00540-009-0826-4
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The Pentax-AWS system is a rigid indirect video laryngoscope with integrated tube guidance. Complications associated with this device are not well understood. We report two cases of epiglottis malposition during intubation with the Pentax-AWS. The standard technique of using the Pentax-AWS system involves direct elevation of the epiglottis for exposure of the vocal cords. The blade tip should be passed posterior to the epiglottis for laryngeal exposure, but pressure on the anterior surface of the epiglottis by the tip can rarely happen even during the correct maneuver. Although the Pentax-AWS provides clear images of the airway structures, it is sometimes difficult to observe the epiglottis continuously because the camera is located beneath the blade tip. Consequently, the view of the epiglottis from the camera may be impeded by the blade tip and may result in undiagnosed epiglottis malposition. The AWS's structural feature and its approach to the larynx can be associated with increased chance of unexpected epiglottis folding. It is particularly important to confirm normal position of the epiglottis during withdrawal of the device to prevent this complication.
引用
收藏
页码:124 / 127
页数:4
相关论文
共 50 条
  • [21] The Pentax-AWS for airway obstruction after tracheal extubation
    Matsumoto, S.
    Shingu, K.
    Asai, T.
    ANAESTHESIA, 2009, 64 (08) : 920 - 920
  • [22] Pentax-AWS airway Scope as an alternative for awake flexible fiberoptic intubation of a morbidly obese patient in the semi-sitting position
    Suzuki, Akihiro
    Terao, Motoi
    Aizawa, Kei
    Sasakawa, Tomoki
    Henderson, John J.
    Iwasaki, Hiroshi
    JOURNAL OF ANESTHESIA, 2009, 23 (01) : 162 - 163
  • [23] Tracheal Intubation With the PENTAX-AWS (Airway Scope) Reduces Changes of Hemodynamic Responses and Bispectral Index Scores Compared With the Macintosh Laryngoscope
    Nishikawa, Koichi
    Matsuoka, Hiroaki
    Saito, Shigeru
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2009, 21 (04) : 292 - 296
  • [24] Pentax-AWS airway Scope as an alternative for awake flexible fiberoptic intubation of a morbidly obese patient in the semi-sitting position
    Akihiro Suzuki
    Motoi Terao
    Kei Aizawa
    Tomoki Sasakawa
    John J. Henderson
    Hiroshi Iwasaki
    Journal of Anesthesia, 2009, 23 : 162 - 163
  • [25] The Pentax-AWS video laryngoscope for emergency airway management
    Corso, Ruggero M.
    Piraccini, Emanuele
    Terzitta, Marina
    Vargas, Juana L. Chanis
    Gaetani, Stefano
    Rotondo, Carmen
    Agnoletti, Vanni
    Gambale, Giorgio
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2011, 29 (09): : 1227 - 1228
  • [26] Pentax-AWS videolaryngoscope for nasotracheal intubation in patients with difficult airways
    Moon, Eun-Jin
    Kim, Mi-Kyeong
    Kim, Keon-Sik
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2013, 64 (01) : 87 - 88
  • [27] Evaluation of the Pentax-AWS® and the Macintosh laryngoscope in difficult intubation: a manikin study
    Kariya, T.
    Inagawa, G.
    Nakamura, K.
    Fujimoto, J.
    Aoi, Y.
    Morita, S.
    Goto, T.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (02) : 223 - 227
  • [28] Validation of the Pentax-AWS Airwayscope utility as an intubation device during cardiopulmonary resuscitation on the ground
    Komasawa, Nobuyasu
    Ueki, Ryusuke
    Itani, Motoi
    Nishi, Shin-ichi
    Kaminoh, Yoshiroh
    JOURNAL OF ANESTHESIA, 2010, 24 (04) : 582 - 586
  • [29] Validation of the Pentax-AWS Airwayscope utility as an intubation device during cardiopulmonary resuscitation on the ground
    Nobuyasu Komasawa
    Ryusuke Ueki
    Motoi Itani
    Shin-ichi Nishi
    Yoshiroh Kaminoh
    Journal of Anesthesia, 2010, 24 : 582 - 586
  • [30] Pentax-AWS® and tube selection
    Akihiro Suzuki
    Takayuki Kunisawa
    Hiroshi Iwasaki
    Canadian Journal of Anesthesia, 2007, 54 : 773 - 774