A new electromechanical method for measuring intraocular pressure

被引:120
|
作者
Kontiola, A [1 ]
机构
[1] Univ Helsinki, Cent Hosp, Dept Ophthalmol, Helsinki, Finland
关键词
acceleration; electromechanical; impact; intraocular pressure; tonometer;
D O I
10.1007/BF02569066
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A new electromechanical method to measure intraocular pressure is presented. A light probe was made to collide with an eye (cornea or sclera) and to bounce back. The impact was registered by an acceleration sensor or the duration of contact with the eye was measured using the phenomenon of the electrical conductivity of biological objects. Laboratory experiments were carried out using pig eyes pressurized with water leveled to different heights. Preliminary clinical trials were carried out comparing the values obtained with those of the Goldmann applanation tonometer. The time of contact and the deceleration time decreases and the deceleration maximum increases in proportion with IOP. A new kind of tonometer can be constructed based on this principle. Measurement can be performed to cornea or sclera without an anesthetic drop. Further study is required to evaluate the accuracy and usefulness of this method.
引用
收藏
页码:265 / 276
页数:12
相关论文
共 50 条
  • [41] MEASURING INTRAOCULAR-PRESSURE IN RABBITS TY TELEMETRY
    MCLAREN, JW
    FITZSIMON, JS
    BRUBAKER, RF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S411 - S411
  • [42] Micro coils for an advanced system for measuring intraocular pressure
    Ullerich, S
    Mokwa, W
    vom Bögel, G
    Schnakenberg, U
    1ST ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2000, : 470 - 474
  • [43] Intraocular Pressure Measuring System Based on Piezoelectric Bimorph
    Tong, Yue
    Xia, Zhengrong
    2012 INTERNATIONAL CONFERENCE ON FUTURE ENERGY, ENVIRONMENT, AND MATERIALS, PT B, 2012, 16 : 1288 - 1294
  • [44] Measuring intraocular pressure using semiconductor laser autodyne
    Usanov, D. A.
    Skripal', An. V.
    Usanova, T. B.
    Dobdin, S. Yu.
    TECHNICAL PHYSICS LETTERS, 2012, 38 (02) : 135 - 137
  • [45] Measuring intraocular pressure using semiconductor laser autodyne
    D. A. Usanov
    An. V. Skripal’
    T. B. Usanova
    S. Yu. Dobdin
    Technical Physics Letters, 2012, 38 : 135 - 137
  • [46] Changes in intraocular pressure after intraocular eye surgery-the influence of measuring technique
    Kovacic, Hrvoje
    Wolfs, Roger C. W.
    Kilic, Emine
    Ramdas, Wishal D.
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (06) : 967 - 973
  • [47] NEW VARIETY OF COMPENSATING METHOD FOR MEASURING VAPOR-PRESSURE
    BORSHCHEVSKII, AS
    ROENKOV, ND
    INDUSTRIAL LABORATORY, 1971, 37 (10): : 1557 - +
  • [48] A NEW METHOD OF CLINICAL ASSESSMENT OF AN INTRAOCULAR PRESSURE SENSITIVE ISCHAEMIC MECHANISM IN GLAUCOMA
    BOYD, TAS
    ROSEN, ES
    CANADIAN JOURNAL OF OPHTHALMOLOGY, 1970, 5 (01): : 12 - &
  • [49] INTRAOCULAR-PRESSURE - NEW PERSPECTIVES
    SHIOSE, Y
    SURVEY OF OPHTHALMOLOGY, 1990, 34 (06) : 413 - 435
  • [50] New perspectives on target intraocular pressure
    Clement, Colin I.
    Bhartiya, Shibal
    Shaarawy, Tarek
    SURVEY OF OPHTHALMOLOGY, 2014, 59 (06) : 615 - 626