A new electromechanical method for measuring intraocular pressure

被引:120
|
作者
Kontiola, A [1 ]
机构
[1] Univ Helsinki, Cent Hosp, Dept Ophthalmol, Helsinki, Finland
关键词
acceleration; electromechanical; impact; intraocular pressure; tonometer;
D O I
10.1007/BF02569066
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A new electromechanical method to measure intraocular pressure is presented. A light probe was made to collide with an eye (cornea or sclera) and to bounce back. The impact was registered by an acceleration sensor or the duration of contact with the eye was measured using the phenomenon of the electrical conductivity of biological objects. Laboratory experiments were carried out using pig eyes pressurized with water leveled to different heights. Preliminary clinical trials were carried out comparing the values obtained with those of the Goldmann applanation tonometer. The time of contact and the deceleration time decreases and the deceleration maximum increases in proportion with IOP. A new kind of tonometer can be constructed based on this principle. Measurement can be performed to cornea or sclera without an anesthetic drop. Further study is required to evaluate the accuracy and usefulness of this method.
引用
收藏
页码:265 / 276
页数:12
相关论文
共 50 条
  • [31] A new method for measuring the pressure in the pulmonary artery.
    Swift, WE
    Haggart, GE
    Drinker, CK
    JOURNAL OF EXPERIMENTAL MEDICINE, 1922, 36 (03): : 329 - U5
  • [32] A new method of measuring the aqueous vapor pressure of soils
    Edlefsen, NE
    SOIL SCIENCE, 1934, 38 (01) : 29 - 35
  • [33] A NEW METHOD FOR MEASURING THE LIMITING NEGATIVE PRESSURE IN LIQUIDS
    BRIGGS, LJ
    SCIENCE, 1949, 109 (2835) : 440 - 440
  • [34] A NEW METHOD OF MEASURING BLOOD-PRESSURE IN MICE
    HICKS, JD
    GILTINAN, P
    PYE, J
    LANCET, 1965, 2 (7419): : 930 - &
  • [35] NEW METHOD OF MEASURING PRESSURE OF SKIN AND SUBCUTANEOUS TISSUE
    PAROT, S
    BOURLIER.
    GERONTOLOGIA, 1967, 13 (02): : 95 - 95
  • [36] Changes in intraocular pressure after intraocular eye surgery——the influence of measuring technique
    Hrvoje Kovacic
    Roger C.W.Wolfs
    Emine K?l??
    Wishal D.Ramdas
    International Journal of Ophthalmology, 2019, (06) : 967 - 973
  • [37] ORAL GLYCEROL IN OPHTHALMOLOGY - A VALUABLE NEW METHOD FOR REDUCTION OF INTRAOCULAR PRESSURE
    VIRNO, M
    BUCCI, MG
    CANTORE, P
    BIETTI, C
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1963, 55 (06) : 1133 - &
  • [38] FURTHER OBSERVATIONS CONCERNING THE CAMPIMETRIC METHOD OF MEASURING INDIVIDUALLY TOLERATED INTRAOCULAR-PRESSURE IN GLAUCOMA
    WODOWOSOW, AM
    BORISKINA, MG
    KOTJELJNIKOWA, OF
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1982, 180 (02) : 135 - 137
  • [39] A passive pressure sensor for continuously measuring the intraocular pressure in glaucomatous patients
    Auvray, P.
    Rousseau, L.
    Lissorgues, G.
    Soulier, F.
    Potin, O.
    Bernard, S.
    Dieuleveult, F.
    Scorsone, E.
    Bergonzo, P.
    Chicaud, L.
    Picaud, S.
    Sahel, J. A.
    IRBM, 2012, 33 (02) : 117 - 122
  • [40] Comparison of three tonometers for measuring intraocular pressure in rabbits
    Abrams, LS
    Vitale, S
    Jampel, HD