AMS 800 sphincter in urinary incontinence after prostatic surgery, based on a series of 16 patients.

被引:0
|
作者
Koutani, A [1 ]
Lechevallier, E [1 ]
Coulange, C [1 ]
机构
[1] Hop Salvator, Serv Urol & Transplantat Renale, F-13274 Marseille 9, France
关键词
prostatic surgery; urinary incontinence; artificial sphincter;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective: to present the results of a series of artificial sphincters implanted for urinary incontinence after prostatic surgery, Patients and methods: from 1987 to 1996, artificial sphincters were implanted for urinary incontinence after prostatic surgery, consisting of one transvesical prostatectomy, 11 prostatic resections and 4 radical prostatectomies. All these patients were evaluate by urine culture, cystourethrography and urethrocystoscopy. Eleven patients underwent urodynamic assessment. The AMS 800 artificial sphincter was used. Results: the mean interval between onset of incontinence and implantation was 18 months. The mean follow-up after implantation of the sphincter was 6 years. An operative wound of the bulbar urethra did not prevent implantation of the sphincter, but required repair and prolonged catheterization (12 days). The mean duration of catheterization was 6 days. The overall functional result was 81 % (13 case), and 75 % of sphincters were functional at 5 years. Five revisions were necessary to maintain functioning of the sphincter in 2 cases of rupture and 1 displacement of the balloon, 1 case of urethral atrophy and 1 rupture of the pump. Three explantations, 2 total and 1 partial, were performed. Two reimplantations were performed after 12 months and 26 months respectively. Conclusion: the AMS 800 artificial sphincter currently represents an effective treatment for urinary incontinence due to sphincter insufficiency after prostatic surgery. However, an old artificial sphincter may require revision to restore function.
引用
收藏
页码:382 / 385
页数:4
相关论文
共 50 条
  • [31] Performance and Safety of the Artificial Urinary Sphincter (AMS 800) for Non-neurogenic Women with Urinary Incontinence Secondary to Intrinsic Sphincter Deficiency: A Systematic Review
    Reus, Christine R.
    Phe, Veronique
    Dechartres, Agnes
    Grilo, Nuno R.
    Chartier-Kastler, Emmanuel J.
    Mozer, Pierre C.
    EUROPEAN UROLOGY FOCUS, 2020, 6 (02): : 327 - 338
  • [32] SUCCESS OF THE ARTIFICIAL URINARY SPHINCTER AFTER FAILED SURGERY FOR INCONTINENCE
    ALIABADI, H
    GONZALEZ, R
    JOURNAL OF UROLOGY, 1990, 143 (05): : 987 - 990
  • [33] An unusual use of AMS 800 artificial urinary sphincter cuff in the treatment of sphincteric neurogenic incontinence: case report
    S Siracusano
    S Ciciliato
    P Di Benedetto
    D Marega
    A Tiberio
    F Stacul
    Spinal Cord, 2004, 42 : 652 - 654
  • [34] An unusual use of AMS 800 artificial urinary sphincter cuff in the treatment of sphincteric neurogenic incontinence: case report
    Siracusano, S
    Ciciliato, S
    Di Benedetto, P
    Marega, D
    Tiberio, A
    Stacul, F
    SPINAL CORD, 2004, 42 (11) : 652 - 654
  • [35] Quality of life, functional outcome and durability of the AMS 800 artificial urinary sphincter in patients with intrinsic sphincter deficiency
    ter Muelen, PH
    Zambon, V
    Kessels, AGH
    Van Kerrebroeck, PEV
    UROLOGIA INTERNATIONALIS, 2003, 71 (01) : 55 - 60
  • [36] Artificial urinary sphincter AMS 800®: What to do in case of failure? Presentation of a diagnostic and therapeutic algorithm for the management of incontinence recurrence in a patient with an artificial urinary sphincter
    Roulette, P.
    Game, X.
    PROGRES EN UROLOGIE, 2014, 24 (01): : F2 - F6
  • [37] SELECTION OF PATIENTS FOR SURGICAL-CORRECTION OF URINARY-INCONTINENCE AFTER PROSTATIC SURGERY
    PETTERSSON, S
    BRATT, CG
    SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 1976, 10 (03): : 205 - 208
  • [38] MAYO-CLINIC EXPERIENCE WITH USE OF THE AMS800 ARTIFICIAL URINARY SPHINCTER FOR URINARY-INCONTINENCE FOLLOWING RADICAL PROSTATECTOMY
    GUNDIAN, JC
    BARRETT, DM
    PARULKAR, BG
    JOURNAL OF UROLOGY, 1989, 142 (06): : 1459 - 1461
  • [39] OBJECTIVE ASSESSMENT OF URINARY-INCONTINENCE AFTER SUCCESSFUL IMPLANTATION OF THE AMS ARTIFICIAL URETHRAL SPHINCTER
    HOLMBENTZEN, M
    KLARSKOV, P
    OPSOMER, R
    MAEGAARD, EM
    HALD, T
    NEUROUROLOGY AND URODYNAMICS, 1985, 4 (01) : 9 - 13
  • [40] Long-term efficacy of AMS 800 artificial urinary sphincter in male patients with urodynamic stress incontinence due to spinal cord lesion
    P Patki
    R Hamid
    P J R Shah
    M Craggs
    Spinal Cord, 2006, 44 : 297 - 300