Commercial Screen-Printed Electrodes Based on Carbon Nanomaterials for a Fast and Cost-Effective Voltammetric Determination of Paracetamol, Ibuprofen and Caffeine in Water Samples

被引:50
|
作者
Serrano, Nuria [1 ]
Castilla, Oscar [1 ]
Arino, Cristina [1 ,2 ]
Silvia Diaz-Cruz, M. [3 ]
Manuel Diaz-Cruz, Jose [1 ]
机构
[1] Univ Barcelona, Dept Chem Engn & Analyt Chem, Marti i Franques 1-11, E-08028 Barcelona, Spain
[2] Univ Barcelona, Inst Recerca Aigua IdRA, E-08028 Barcelona, Spain
[3] CSIC, Spanish Council Sci Res, Inst Environm Assessment & Water Res, Dept Environm Chem,IDAEA, Jordi Girona 18-26, Barcelona 08034, Spain
关键词
screen-printed electrodes; carbon nanomaterials; voltammetry; ibuprofen; paracetamol; caffeine; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; PHARMACEUTICALS; PASTE;
D O I
10.3390/s19184039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carbon screen-printed electrode (SPCE), multi-walled carbon nanotubes modified screen-printed electrode (SPCNTE), carbon nanofibers modified screen-printed electrode (SPCNFE), and graphene modified screen-printed electrode (SPGPHE) were in a pioneer way tested as sensors for the simultaneous determination of the two most consumed pain-killers, paracetamol (PA) and ibuprofen (IB), and the stimulant caffeine (CF) in water by differential pulse voltammetry (DPV). Their analytical performances were compared, and the resulting sensitivities (2.50, 0.074, and 0.24 mu A V mg(-1) L for PA, IB, and CF, respectively), detection limits (0.03, 0.6, and 0.05 mg L-1 for PA, IB, and CF, respectively) and quantification limits (0.09, 2.2, and 0.2 mg L-1 for PA, IB, and CF, respectively) suggested that the SPCNFE was the most suitable carbon-based electrode for the voltammetric determination of the selected analytes in water at trace levels. The methodology was validated using both spiked tap water and hospital wastewater samples. The results were compared to those achieved by liquid chromatography-tandem mass spectrometry (LC-MS/MS), the technique of choice for the determination of the target analytes.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Screen-Printed Nanohybrid Palladium-Based Electrodes for Fast and Simple Determination of Estradiol in Livestock
    Lopes, Claudio Sabbatini Capella
    Silva, Francisco Walison Lima
    Fernandes, Juliana dos Santos
    Fernandes, Julia Oliveira
    Ferreira, Joao H. A.
    Brandao, Felipe Zandonadi
    Santelli, Ricardo Erthal
    Canevari, Thiago C.
    Cincotto, Fernando Henrique
    ACS OMEGA, 2024, 9 (48): : 47729 - 47738
  • [42] Pharmaceutical Electrochemistry: the Electrochemical Oxidation of Paracetamol and Its Voltammetric Sensing in Biological Samples Based on Screen Printed Graphene Electrodes
    Fernandez, Carlos
    Heger, Zbynek
    Kizek, Rene
    Ramakrishnappa, Thippeswamy
    Borun, Agnieszka
    Faisal, Nadimul H.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (09): : 7440 - 7452
  • [43] Electrochemical study and flow injection analysis of paracetamol in pharmaceutical formulations based on screen-printed electrodes and carbon nanotubes
    Fanjul-Bolado, Pablo
    Jose Lamas-Ardisana, Pedro
    Hernandez-Santos, David
    Costa-Garcia, Agustin
    ANALYTICA CHIMICA ACTA, 2009, 638 (02) : 133 - 138
  • [44] VOLTAMMETRIC BEHAVIOR OF SCREEN-PRINTED CARBON ELECTRODES, CHEMICALLY MODIFIED WITH SELECTED MEDIATORS, AND THEIR APPLICATION AS SENSORS FOR THE DETERMINATION OF REDUCED GLUTATHIONE
    WRING, SA
    HART, JP
    BIRCH, BJ
    ANALYST, 1991, 116 (02) : 123 - 129
  • [45] Voltammetric determination of uric acid using a miniaturized platform based on screen-printed electrodes modified with platinum nanoparticles
    Gomes-Junior, Paulo Cardoso
    Nascimento, Evair Dias
    Augusto, Karen Kenlderi de Lima
    Longatto, Gustavo Patelli
    Faria, Ronaldo Censi
    Piccin, Evandro
    Fatibello-Filho, Orlando
    MICROCHEMICAL JOURNAL, 2024, 207
  • [46] Cyclic voltammetric determination of capsaicin by using electrochemically deposited tin and reduced graphene oxide on screen-printed carbon electrodes
    Numphud, Wasukamol
    Chienthavorn, Orapin
    Siriwatcharapiboon, Wilai
    SCIENCEASIA, 2020, 46 (05): : 586 - +
  • [47] Voltammetric Determination of Trace Methyl Parathion using Electrochemically Reduced Graphene Oxide Modified Carbon Screen-Printed Electrodes
    Azimi, Hesameddin
    Sullivan, Connor
    Lu, Dingnan
    Brack, Eric
    Drew, Christopher
    Kurup, Pradeep
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (05): : 356 - 370
  • [48] Voltammetric Determination of Uric Acid in Clinical Serum Samples Using DMF Modified Screen Printed Carbon Electrodes
    Metto, Melaku
    Eramias, Samrawit
    Gelagay, Bekele
    Washe, Alemayehu P.
    INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY, 2019, 2019
  • [49] Comparative voltammetric determination of ascorbic acid at three different carbon electrodes: application of carbon screen-printed electrode for citrus fruits analysis
    Paina, Talytha Rodrigues Gaspari
    Eleoterio, Izabel Cristina
    Stradiotto, Nelson Ramos
    de Oliveira, Marcelo Firmino
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2025, 15 (02):
  • [50] Adsorptive stripping voltammetric method for the determination of caffeine at integrated three-electrode screen-printed sensor with carbon/carbon nanofibers working electrode
    Tyszczuk-Rotko, Katarzyna
    Pietrzak, Karolina
    Sasal, Agnieszka
    ADSORPTION-JOURNAL OF THE INTERNATIONAL ADSORPTION SOCIETY, 2019, 25 (04): : 913 - 921