VOLTAMMETRIC BEHAVIOR OF SCREEN-PRINTED CARBON ELECTRODES, CHEMICALLY MODIFIED WITH SELECTED MEDIATORS, AND THEIR APPLICATION AS SENSORS FOR THE DETERMINATION OF REDUCED GLUTATHIONE

被引:72
|
作者
WRING, SA
HART, JP
BIRCH, BJ
机构
[1] BRISTOL POLYTECH,DEPT SCI,COLDHARBOUR LANE,BRISTOL BS16 1QY,ENGLAND
[2] UNILEVER RES LABS,SENSORS GRP,SHARNBROOK MK44 1LQ,BEDS,ENGLAND
关键词
SCREEN-PRINTED CARBON ELECTRODES; CHEMICALLY MODIFIED FERROCENE; PHTHALOCYANINE AND HEXACYANOFERRATE(III) MEDIATO; REDUCED GLUTATHIONE; CYCLIC VOLTAMMETRY; AMPEROMETRY;
D O I
10.1039/an9911600123
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The evaluation of screen-printed carbon electrodes, chemically modified with selected ferrocene, phthalocyanine and hexacyanoferrate(III) derivative mediators for the determination of reduced glutathione (GSH), is described. Cyclic voltammetry was used to investigate the effect of pH on the electrochemical behaviour of these mediators incorporated in the disposable electrodes. Values of the electron-transfer coefficient (alpha-n(a)) were calculated for the oxidation of the mediators in phosphate buffer solution and solutions containing 0.48 mmol dm-3 GSH. Amperometry in stirred solutions was used to construct hydrodynamic voltammograms for each of the modified electrodes; these voltammograms were used to elucidate their steady-state behaviour. Both electrochemical techniques were used to calculate the reduction in overpotential for the oxidation of GSH; these calculations were performed for all of the chemically modified electrodes. Amperometry in stirred solutions was used as the technique for quantitative measurements, to determine the calibration response factors (mu-A mmol-1 dm3) and limits of detection for selected mediators towards GSH. The appropriate applied potentials were selected by reference to the hydrodynamic waves; a range of values were investigated to find the potential that gave the maximum sensitivity. The most promising mediators were cobalt phthalocyanine, iron phthalocyanine and ferrocenecarbaldehyde.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 50 条
  • [1] CHEMICALLY MODIFIED, SCREEN-PRINTED CARBON ELECTRODES
    WRING, SA
    HART, JP
    ANALYST, 1992, 117 (08) : 1281 - 1286
  • [2] Voltammetric Determination of Phenylalanine Using Chemically Modified Screen-Printed Based Sensors
    Dinu, Ancuta
    Apetrei, Constantin
    CHEMOSENSORS, 2020, 8 (04) : 1 - 18
  • [3] DEVELOPMENT OF AN AMPEROMETRIC ASSAY FOR THE DETERMINATION OF REDUCED GLUTATHIONE, USING GLUTATHIONE-PEROXIDASE AND SCREEN-PRINTED CARBON ELECTRODES CHEMICALLY MODIFIED WITH COBALT PHTHALOCYANINE
    WRING, SA
    HART, JP
    BIRCH, BJ
    ELECTROANALYSIS, 1992, 4 (03) : 299 - 309
  • [4] Voltammetric determination of Rutin at Screen-Printed carbon disposable electrodes
    de Oliveira-Roberth, Aline
    Santos, Diego I. V.
    Cordeiro, Diogo D.
    Lino, Fernando M. de A.
    Bara, Maria T. F.
    Gil, Eric de S.
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2012, 10 (05): : 1609 - 1616
  • [5] Voltammetric Determination of Levodopa Using Mesoporous Carbon-Modified Screen-Printed Carbon Sensors
    Dascalescu, Dorin
    Apetrei, Constantin
    SENSORS, 2021, 21 (18)
  • [6] Voltammetric determination of sulfamethoxazole using commercial screen-printed carbon electrodes
    Alberto, Elena
    Bastos-Arrieta, Julio
    Perez-Rafols, Clara
    Serrano, Nuria
    Diaz-Cruz, M. Silvia
    Diaz-Cruz, Jose Manuel
    MICROCHEMICAL JOURNAL, 2023, 193
  • [7] Voltammetric Determination of Trace Methyl Parathion using Electrochemically Reduced Graphene Oxide Modified Carbon Screen-Printed Electrodes
    Azimi, Hesameddin
    Sullivan, Connor
    Lu, Dingnan
    Brack, Eric
    Drew, Christopher
    Kurup, Pradeep
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (05): : 356 - 370
  • [8] Voltammetric Determination of Anticancer Drug Flutamide at Screen-Printed Carbon Electrodes
    Vyskocil, Vlastimil
    Navratil, Tomas
    Barek, Jiri
    MODERN ELECTROCHEMICAL METHODS XXXI, 2011, : 190 - 194
  • [9] Voltammetric behavior and trace determination of cadmium at a calixarene modified screen-printed carbon electrode
    Honeychurch, KC
    Hart, JP
    Cowell, DC
    Arrigan, DWM
    ELECTROANALYSIS, 2002, 14 (03) : 177 - 185
  • [10] Comparative voltammetric behavior of indigo carmine at screen-printed carbon electrodes
    Díaz-González, M
    Fernández-Sánchez, C
    Costa-García, A
    ELECTROANALYSIS, 2002, 14 (10) : 665 - 670