Percentage depth dose evaluation in heterogeneous media using thermoluminescent dosimetry

被引:19
|
作者
da Rosa, L. A. R. [2 ]
Cardoso, S. C. [1 ]
Campos, L. T. [2 ]
Alves, V. G. L. [1 ]
Batista, D. V. S. [3 ]
Facure, A. [4 ]
机构
[1] Univ Fed Rio de Janeiro, Inst Fis, IRD CNEN, BR-21941972 Rio De Janeiro, Brazil
[2] Univ Fed Rio de Janeiro, Inst Radioprotecao & Dosimetria, BR-21941972 Rio De Janeiro, Brazil
[3] INCA, Inst Nacl Canc, Rio De Janeiro, Brazil
[4] Comissao Nacl Energia Nucl, Rio De Janeiro, Brazil
来源
关键词
thermoluminescent detector; lung heterogeneity; small field size; 15; MV; treatment planning system; MONTE-CARLO; STEREOTACTIC RADIOSURGERY; ENERGY; BEAMS; DISTRIBUTIONS; RADIOTHERAPY; ALGORITHMS; TRANSPORT; TLD-100; IMPACT;
D O I
10.1120/jacmp.v11i1.2947
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study is to investigate the influence of lung heterogeneity inside a soft tissue phantom on percentage depth dose (PDD). PDD curves were obtained experimentally using LiF: Mg,Ti (TLD-100) thermoluminescent detectors and applying Eclipse treatment planning system algorithms Batho, modified Batho (M-Batho or BMod), equivalent TAR (E-TAR or EQTAR), and anisotropic analytical algorithm (AAA) for a 15 MV photon beam and field sizes of 1 x 1, 2 x 2, 5 x 5, and 10 x 10 cm(2). Monte Carlo simulations were performed using the DOSRZnrc user code of EGSnrc. The experimental results agree with Monte Carlo simulations for all irradiation field sizes. Comparisons with Monte Carlo calculations show that the AAA algorithm provides the best simulations of PDD curves for all field sizes investigated. However, even this algorithm cannot accurately predict PDD values in the lung for field sizes of 1 x 1 and 2 x 2 cm(2). An overdos-age in the lung of about 40% and 20% is calculated by the AAA algorithm close to the interface soft tissue/lung for 1 x 1 and 2 x 2 cm(2) field sizes, respectively. It was demonstrated that differences of 100% between Monte Carlo results and the algorithms Batho, modified Batho, and equivalent TAR responses may exist inside the lung region for the 1 x 1 cm(2) field.
引用
收藏
页码:117 / 127
页数:11
相关论文
共 50 条
  • [41] Comprehensive evaluation of Kodak's EDR2 film for depth dose dosimetry
    Dogan, N
    Leybovich, LB
    Sethi, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1367 - 1367
  • [42] MULTICELLULAR DOSIMETRY FOR BETA-EMITTING RADIONUCLIDES - AUTORADIOGRAPHY, THERMOLUMINESCENT DOSIMETRY AND 3-DIMENSIONAL DOSE CALCULATIONS
    YORKE, ED
    WILLIAMS, LE
    DEMIDECKI, AJ
    HEIDORN, DB
    ROBERSON, PL
    WESSELS, BW
    MEDICAL PHYSICS, 1993, 20 (02) : 543 - 550
  • [43] INNOVATIVE METHODS USING OF 2-D THERMOLUMINESCENT DOSIMETRY
    Kopec, Renata
    MEDICAL PHYSICS IN THE BALTIC STATES, 2013, : 180 - 180
  • [44] Stereotactic radiosurgery dosimetry using thermoluminescent dosimeters and radiochromic films
    Avila-Rodríguez, MA
    Rodríguez-Villafuerte, M
    Perches, RD
    MEDICAL PHYSICS, 2000, 538 : 213 - 218
  • [45] NEUTRON DOSIMETRY USING ACTIVATION OF THERMOLUMINESCENT CASO4
    AZORIN, J
    GUTIERREZ, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 227 (01): : 150 - 153
  • [46] AN EVALUATION OF AN EQUATION WHICH ESTIMATES PERCENTAGE DEPTH DOSE DURING COBALT-60 TELETHERAPY
    SCHAEFLE.JW
    NEBLETT, DL
    STERLING, TD
    HEALTH PHYSICS, 1965, 11 (08): : 838 - +
  • [47] Monte Carlo simulations of EBT3 film dose deposition for percentage depth dose (PDD) curve evaluation
    Robinson, Spencer M.
    Esplen, Nolan
    Wells, Derek
    Bazalova-Carter, Magdalena
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (12): : 314 - 324
  • [48] DOSE MEASUREMENTS IN TELETHERAPY USING THERMOLUMINESCENT DOSIMETERS
    Ghtulescu, Zoe
    Stochioiu, Ana
    Dumitrache, Mihai
    ROMANIAN REPORTS IN PHYSICS, 2011, 63 (03) : 700 - 706
  • [49] A thermoluminescent dosimetry postal dose inter-comparison of radiation therapy centres in Malaysia
    Rassiah P.
    Ng K.H.
    DeWerd L.A.
    Kunugi K.
    Australasian Physics & Engineering Sciences in Medicine, 2004, 27 (1): : 25 - 29
  • [50] Dose distributions and percentage depth dose measurements for a total skin electron therapy
    Licona, I.
    Figueroa-Medina, E.
    Gamboa-deBuen, I.
    RADIATION MEASUREMENTS, 2017, 106 : 365 - 372