DISCRETE CONTROL OF AIR CONDITIONING UNITS IN MISSION CRITICAL FACILITIES

被引:0
|
作者
Bermudez, Sergio A. [1 ]
Hamann, Hendrik F. [1 ]
Klein, Levente J. [1 ]
Marianno, Fernando J. [1 ]
Claassen, Alan C. [1 ]
机构
[1] IBM Corp, TJ Watson Res Ctr, Yorktown Hts, NY USA
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
For redundancy, almost all mission-critical facilities such as data centers are fitted with more air condition units than required. These units are most of the time heavily underutilized, where the fans within the units are still consuming energy circulating air without actually providing cooling. In more modern facilities such fans are equipped with variable frequency drives, which can reduce substantially the energy consumption if proper controls are implemented. While there have several solutions for controlling and optimizing such variable frequency drive operated air conditioning units, control systems without variable frequency drives (discrete on/off ACU controls) have not been addressed thoroughly. In this paper, we present a practical, distributed and automatic control method for such discrete air conditioning units. The technique includes several safety features and is based on dense environmental sensing and events like hotspots or device failures. We discuss this approach by way of example of a case study.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] COMFORT IN PASSENGER COACHES - BBC COMPACT UNITS FOR AIR-CONDITIONING AND ELECTRONIC TEMPERATURE CONTROL.
    Strub, P.
    1978, 65 (12): : 827 - 831
  • [42] A convolutional neural network to control sound level for air conditioning units in four different classroom conditions
    Muthuraj, Kiranraj
    Othmani, Cherif
    Krause, Ralph
    Oppelt, Thomas
    Merchel, Sebastian
    Altinsoy, M. Ercan
    ENERGY AND BUILDINGS, 2024, 324
  • [43] Optimizing location and relocation of response units in guarding critical facilities
    Sathe, A
    Miller-Hooks, E
    NETWORK MODELING 2005, 2005, (1923): : 127 - 136
  • [44] RESPIRATORY HYPERSENSITIVITY DUE TO MOLDS IN AIR-CONDITIONING UNITS
    FINK, JN
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1972, 222 (03): : 374 - &
  • [45] ABCS OF AIR CONDITIONING .9. AIR MOVING DEVICES (B) AIR HANDLING UNITS
    GOSLING, CT
    MODERN REFRIGERATION AND AIR CONDITIONING, 1969, 72 (860): : 34 - &
  • [46] CORROSION IN AIR-CONDITIONING UNITS - OCCURRENCE AND POSSIBILITIES FOR PREVENTION
    SCHARMANN, R
    KALTE UND KLIMATECHNIK, 1979, 32 (08): : 370 - 372
  • [47] UK air conditioning units for Polish-built ships
    不详
    NAVAL ARCHITECT, 2001, : 16 - 16
  • [48] Fungal contamination of air conditioning units in operating theatres in India
    Kelkar, U
    Bal, AM
    Kulkarni, S
    JOURNAL OF HOSPITAL INFECTION, 2005, 60 (01) : 81 - 84
  • [49] Characteristics of condensation formation on the surfaces of air conditioning indoor units
    Jin, Guangri
    Lee, Kwan-Soo
    Seo, Beomsoo
    APPLIED THERMAL ENGINEERING, 2015, 91 : 345 - 353
  • [50] Air conditioning system noise control
    不详
    SOUND AND VIBRATION, 1995, 29 (11): : 14 - 14