DISCRETE CONTROL OF AIR CONDITIONING UNITS IN MISSION CRITICAL FACILITIES

被引:0
|
作者
Bermudez, Sergio A. [1 ]
Hamann, Hendrik F. [1 ]
Klein, Levente J. [1 ]
Marianno, Fernando J. [1 ]
Claassen, Alan C. [1 ]
机构
[1] IBM Corp, TJ Watson Res Ctr, Yorktown Hts, NY USA
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
For redundancy, almost all mission-critical facilities such as data centers are fitted with more air condition units than required. These units are most of the time heavily underutilized, where the fans within the units are still consuming energy circulating air without actually providing cooling. In more modern facilities such fans are equipped with variable frequency drives, which can reduce substantially the energy consumption if proper controls are implemented. While there have several solutions for controlling and optimizing such variable frequency drive operated air conditioning units, control systems without variable frequency drives (discrete on/off ACU controls) have not been addressed thoroughly. In this paper, we present a practical, distributed and automatic control method for such discrete air conditioning units. The technique includes several safety features and is based on dense environmental sensing and events like hotspots or device failures. We discuss this approach by way of example of a case study.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Mission Critical Facilities, Technology Spaces, & Electronic Equipment
    Ellsworth, Michael J., Jr.
    2012 SC COMPANION: HIGH PERFORMANCE COMPUTING, NETWORKING, STORAGE AND ANALYSIS (SCC), 2012, : 942 - 961
  • [22] MODELING MISSION CRITICAL FACILITIES FOR LEED: LESSONS LEARNED
    Baker, Kristopher S.
    Jia, Xun
    2018 BUILDING PERFORMANCE ANALYSIS CONFERENCE AND SIMBUILD, 2018, : 581 - 587
  • [23] Smart Power Supply Systems for Mission Critical Facilities
    Hirose, Keiichi
    Babasaki, Tadatoshi
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2012, E95B (03) : 755 - 772
  • [24] REDUCING ENERGY USAGE IN DATA CENTERS THROUGH CONTROL OF ROOM AIR CONDITIONING UNITS
    Iyengar, Madhusudan
    Schmidt, Roger
    Caricari, Joe
    2010 12TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, 2010,
  • [25] PROPOSAL OF OPTIMAL COOPERATIVE CONTROL METHOD FOR AIR CONDITIONING INDOOR UNITS USING SPARSENESS
    Nishijima Y.
    Shiraishi Y.
    Nagahara M.
    Journal of Environmental Engineering (Japan), 2023, 88 (807): : 447 - 453
  • [27] Air traffic control facilities
    TR News, 1997, (191):
  • [28] Bacterial control conditioning in air
    Carswell, TS
    Doubly, JA
    Nason, HK
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1937, 29 : 85 - 89
  • [29] The hidden costs of concealing outdoor air conditioning units
    Wei Wang
    Yuwen Deng
    Jiyuan Wu
    Zhe Wang
    Hailu Wei
    Qinran Hu
    Tianzhen Hong
    Tao Qian
    Nature Cities, 2024, 1 (11): : 722 - 724
  • [30] An alternative field test for spot air conditioning units
    Wong, Kau-Fui V.
    Valdes, Diego
    Goad, Joshua
    Losada, Jesse
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 6: ENERGY SYSTEMS: ANALYSIS, THERMODYNAMICS AND SUSTAINABILITY, 2008, : 367 - 371