Large area flat crystal x-ray spectrometer with high integrated intensity for an electron beam ion trap

被引:17
|
作者
Nakamura, N [1 ]
机构
[1] JST, ICORP, Cold Trapped Ions Project, Tokyo 1820024, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2000年 / 71卷 / 11期
关键词
D O I
10.1063/1.1319978
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A flat crystal x-ray spectrometer has been constructed for spectroscopic studies of highly charged ions with an electron beam ion trap. It consists of a flat crystal and a position sensitive proportional counter. Employment of a flat crystal yields easy alignment, easy processing of the crystal, and high flexibility. The proportional counter has been designed to have a large effective area, which is needed to compensate for weak focusing power of a flat crystal. The utility of the new spectrometer has been demonstrated with the Tokyo electron beam ion trap. (C) 2000 American Institute of Physics. [S0034-6748(90)01212-6].
引用
收藏
页码:4065 / 4069
页数:5
相关论文
共 50 条
  • [41] A High-Efficiency X-Ray Crystal Spectrometer for X-Ray Thomson Scattering
    张小丁
    张继彦
    杨国洪
    韦敏习
    胡广月
    赵斌
    郑坚
    Plasma Science and Technology, 2013, 15 (08) : 755 - 759
  • [42] X-ray emission from highly charged ions colliding with a relativistic electron beam in the SuperEBIT electron beam ion trap
    Beiersdorfer, P
    Beck, B
    Becker, JA
    Lepson, JK
    Reed, KJ
    X-RAY AND INNER-SHELL PROCESSES, 2003, 652 : 131 - 140
  • [43] Ion beam lithography for direct patterning of high accuracy large area X-ray elements in gold on membranes
    Nadzeyka, A.
    Peto, L.
    Bauerdick, S.
    Mayer, M.
    Keskinbora, K.
    Grevent, C.
    Weigand, M.
    Hirscher, M.
    Schuetz, G.
    MICROELECTRONIC ENGINEERING, 2012, 98 : 198 - 201
  • [44] High-resolution x-ray spectromicroscopy with the Tokyo electron beam ion
    Nakamura, N
    Faenov, AY
    Pikuz, TA
    Nojikawa, E
    Shiraishi, H
    Currell, FJ
    Ohtani, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (03): : 1658 - 1664
  • [45] An X-ray spectrometer using a two-dimensional PSPC and a flat crystal
    Mizogawa, T
    PHYSICA SCRIPTA, 1997, T73 : 403 - 404
  • [46] High intensity monochromatic x-ray beam using doubly curved crystal optics
    Chen, ZW
    Nicolich, JP
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS, 2000, 4144 : 110 - 115
  • [47] Simulating cometary and stellar X-ray emission in the laboratory using microcalorimeters and an electron beam ion trap
    Brown, GV
    Beiersdorfer, P
    Chen, H
    Graf, A
    May, M
    Terracol, S
    Thorn, D
    Boyce, KR
    Cottam, J
    Gendreau, KC
    Kahn, SM
    Kelley, RL
    Kilbourne, CA
    Porter, FS
    Szymkowiak, AE
    ATOMIC PROCESSES IN PLASMAS, 2004, 730 : 203 - 212
  • [48] X-RAY SPECTROSCOPY OF HIGHLY-IONIZED ATOMS IN AN ELECTRON-BEAM ION TRAP (EBIT)
    MARRS, RE
    BENNETT, C
    CHEN, MH
    COWAN, T
    DIETRICH, D
    HENDERSON, JR
    KNAPP, DA
    LEVINE, MA
    REED, KJ
    SCHNEIDER, MB
    SCOFIELD, JH
    JOURNAL DE PHYSIQUE, 1989, 50 (C-1): : 445 - 458
  • [49] Chandrayaan-2 Large Area Soft X-ray Spectrometer
    Radhakrishna, V
    Tyagi, A.
    Narendranath, S.
    Vadodariya, Koushal
    Yadav, Reena
    Singh, Brajpal
    Balaji, G.
    Satya, Neeraj
    Shetty, Akash
    Kumar, H. N. Suresha
    Kumar
    Vaishali, S.
    Pillar, Netra S.
    Tadepalli, S.
    Raghavendra, Venkata
    Sreekumar, P.
    Agarwal, Anil
    Valarmathi, N.
    CURRENT SCIENCE, 2020, 118 (02): : 219 - 225
  • [50] A SINGLE CRYSTAL HIGH TEMPERATURE HEATER FOR AN X-RAY SPECTROMETER
    LEFKER, R
    DEBRETTEVILLE, A
    DODD, JS
    PHYSICAL REVIEW, 1953, 90 (02): : 345 - 346