Computational and Phantom-Based Feasibility Study of 3D dcNCI With Ultra-Low-Field MRI

被引:1
|
作者
Hofner, Nora [1 ]
Storm, Jan-Hendrik [1 ]
Hommen, Peter [1 ]
Cassara, Antonino Mario [2 ]
Korber, Rainer [1 ]
机构
[1] Phys Tech Bundesanstalt, Berlin, Germany
[2] Fdn Res Informat Technol Soc ITIS, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
ultra-low-field magnetic resonance imaging; neuronal current imaging; current dipole phantom; MEG; simulation; NEURONAL MAGNETIC-FIELDS; MICROTESLA MRI; HUMAN BRAIN; CURRENTS; SYSTEM; SIGNAL; NMR;
D O I
10.3389/fphy.2021.647376
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The possibility to directly and non-invasively localize neuronal activities in the human brain, as for instance by performing neuronal current imaging (NCI) via magnetic resonance imaging (MRI), would be a breakthrough in neuroscience. In order to assess the feasibility of 3-dimensional (3D) NCI, comprehensive computational and physical phantom experiments using low-noise ultra-low-field (ULF) MRI technology were performed using two different source models within spherical phantoms. The source models, consisting of a single dipole and an extended dipole grid, were calibrated enabling the quantitative emulation of a long-lasting neuronal activity by the application of known current waveforms. The dcNCI experiments were also simulated by solving the Bloch equations using the calculated internal magnetic field distributions of the phantoms and idealized MRI fields. The simulations were then validated by physical phantom experiments using a moderate polarization field of 17 mT. A focal activity with an equivalent current dipole of about 150 nAm and a physiologically relevant depth of 35 mm could be resolved with an isotropic voxel size of 25 mm. The simulation tool enabled the optimization of the imaging parameters for sustained neuronal activities in order to predict maximum sensitivity.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Image based meshing of packed beds of cylinders at low aspect ratios using 3d MRI coupled with computational fluid dynamics
    Baker, M. J.
    Young, P. G.
    Tabor, G. R.
    COMPUTERS & CHEMICAL ENGINEERING, 2011, 35 (10) : 1969 - 1977
  • [32] Simulation Based Feasibility Study of Wireless RF Interconnects for 3D ICs
    More, Ankit
    Taskin, Baris
    IEEE ANNUAL SYMPOSIUM ON VLSI (ISVLSI 2010), 2010, : 228 - 231
  • [33] Feasibility study on 3D image reconstruction from 2D orthogonal cine-MRI for MRI-guided radiotherapy
    Paganelli, Chiara
    Lee, Danny
    Kipritidis, John
    Whelan, Brendan
    Greer, Peter B.
    Baroni, Guido
    Riboldi, Marco
    Keall, Paul
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2018, 62 (03) : 389 - 400
  • [34] A novel bone suppression algorithm in intensity-based 2D/3D image registration for real-time tumor motion monitoring: Development and phantom-based validation
    Gulyas, Ingo
    Trnkova, Petra
    Knaeusl, Barbara
    Widder, Joachim
    Georg, Dietmar
    Renner, Andreas
    MEDICAL PHYSICS, 2022, 49 (08) : 5182 - 5194
  • [35] 3D Surface Imaging as a Viable Replacement for Permanent Tattoos for Patients Undergoing Breast EBRT - A Feasibility Study on a Phantom
    Song, Y.
    Tamas, P.
    Hong, L.
    Mueller, B. A.
    Braunstein, L. Z.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E351 - E351
  • [36] Quantitative 3D Analysis of Levator Ani Muscle Subdivisions in Nulliparous Women: MRI Feasibility Study
    Moser, Nathalie
    Skawran, Stephan
    Steigmiller, Klaus
    Roehrnbauer, Barbara
    Winklehner, Thomas
    Reiner, Caecilia S.
    Betschart, Cornelia
    DIAGNOSTICS, 2024, 14 (09)
  • [37] Study on 3D Model Reconstruction of Human Knee Joint Based on MRI
    Han, Yuemei
    MEASUREMENT TECHNOLOGY AND ENGINEERING RESEARCHES IN INDUSTRY, PTS 1-3, 2013, 333-335 : 934 - 937
  • [38] Validation of 3D Ultra-Short TE (UTE) Phase-Contrast MRI for Imaging of Steady Flow: Initial Phantom Experiments
    Kadbi, Mo
    Negahdar, M. J.
    Cha, Jung Won
    Traughber, Melanie
    Martin, Peter
    Amini, Amir A.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 372 - 376
  • [39] Clinical Use of Bedside Portable Ultra-Low-Field Brain Magnetic Resonance Imaging in Patients on Extracorporeal Membrane Oxygenation: Results From the Multicenter SAFE MRI ECMO Study
    Cho, Sung-Min
    Khanduja, Shivalika
    Wilcox, Christopher
    Dinh, Kha
    Kim, Jiah
    Kang, Jin Kook
    Chinedozi, Ifeanyi David
    Darby, Zachary
    Acton, Matthew
    Rando, Hannah
    Briscoe, Jessica
    Bush, Errol L.
    Sair, Haris I.
    Pitts, John
    Arlinghaus, Lori R.
    Wandji, Audrey-Carelle N.
    Moreno, Elena
    Torres, Glenda
    Akkanti, Bindu
    Gavito-Higuera, Jose
    Keller, Steven
    Choi, HuiMahn A.
    Kim, Bo Soo
    Gusdon, Aaron
    Whitman, Glenn J.
    CIRCULATION, 2024, 150 (24) : 1955 - 1965
  • [40] Characterization and 3D correction of geometric distortion in low-field open-magnet MRI
    Viard, Romain
    Betrouni, Nacirn
    Vermandel, Maximilien
    Mordon, Serge
    Rousseau, Jean
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 3649 - 3652