Computational and Phantom-Based Feasibility Study of 3D dcNCI With Ultra-Low-Field MRI

被引:1
|
作者
Hofner, Nora [1 ]
Storm, Jan-Hendrik [1 ]
Hommen, Peter [1 ]
Cassara, Antonino Mario [2 ]
Korber, Rainer [1 ]
机构
[1] Phys Tech Bundesanstalt, Berlin, Germany
[2] Fdn Res Informat Technol Soc ITIS, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
ultra-low-field magnetic resonance imaging; neuronal current imaging; current dipole phantom; MEG; simulation; NEURONAL MAGNETIC-FIELDS; MICROTESLA MRI; HUMAN BRAIN; CURRENTS; SYSTEM; SIGNAL; NMR;
D O I
10.3389/fphy.2021.647376
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The possibility to directly and non-invasively localize neuronal activities in the human brain, as for instance by performing neuronal current imaging (NCI) via magnetic resonance imaging (MRI), would be a breakthrough in neuroscience. In order to assess the feasibility of 3-dimensional (3D) NCI, comprehensive computational and physical phantom experiments using low-noise ultra-low-field (ULF) MRI technology were performed using two different source models within spherical phantoms. The source models, consisting of a single dipole and an extended dipole grid, were calibrated enabling the quantitative emulation of a long-lasting neuronal activity by the application of known current waveforms. The dcNCI experiments were also simulated by solving the Bloch equations using the calculated internal magnetic field distributions of the phantoms and idealized MRI fields. The simulations were then validated by physical phantom experiments using a moderate polarization field of 17 mT. A focal activity with an equivalent current dipole of about 150 nAm and a physiologically relevant depth of 35 mm could be resolved with an isotropic voxel size of 25 mm. The simulation tool enabled the optimization of the imaging parameters for sustained neuronal activities in order to predict maximum sensitivity.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Feasibility Study of Polymer Gel Dosimetry Using a 3D Printed Phantom for Liver Cancer Radiotherapy
    Lee, Minsik
    Noh, Seonyeong
    Yoon, KyoungJun
    Lee, Sang-Wook
    Yoon, Sang Min
    Jung, Jinhong
    Jeong, Chiyoung
    Kwak, Jungwon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (06) : 453 - 457
  • [22] Feasibility of a phantom with 3D printed inserts with realistic uptake patterns to study the performance of radiomics features
    Pfaehler, E.
    van Sluis, J.
    Merema, B.
    van Ooijen, P.
    van Velden, F. H. P.
    Boellaard, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S46 - S47
  • [23] A reduced micro-dose protocol for 3D reconstruction of the spine in children with scoliosis: results of a phantom-based and clinically validated study using stereo-radiography
    Peter H. Pedersen
    Claudio Vergari
    Abdulmajeed Alzakri
    Raphaël Vialle
    Wafa Skalli
    European Radiology, 2019, 29 : 1874 - 1881
  • [24] A reduced micro-dose protocol for 3D reconstruction of the spine in children with scoliosis: results of a phantom-based and clinically validated study using stereo-radiography
    Pedersen, Peter H.
    Vergari, Claudio
    Alzakri, Abdulmajeed
    Vialle, Raphael
    Skalli, Wafa
    EUROPEAN RADIOLOGY, 2019, 29 (04) : 1874 - 1881
  • [25] 3D Bioprinting of Acellular Corneal Stromal Scaffolds with a Low Cost Modified 3D Printer: A Feasibility Study
    Gingras, Amelia A.
    Jansen, Peter A.
    Smith, Caroline
    Zhang, Xu
    Niu, Ye
    Zhao, Yi
    Roberts, Cynthia J.
    Herderick, Edward D.
    Swindle-Reilly, Katelyn E.
    CURRENT EYE RESEARCH, 2023, 48 (12) : 1112 - 1121
  • [26] 3D hindfoot alignment measurements based on low-dose biplanar radiographs: a clinical feasibility study
    Andrea B. Rosskopf
    Reto Sutter
    Christian W. A. Pfirrmann
    Florian M. Buck
    Skeletal Radiology, 2019, 48 : 707 - 712
  • [27] 3D hindfoot alignment measurements based on low-dose biplanar radiographs: a clinical feasibility study
    Rosskopf, Andrea B.
    Sutter, Reto
    Pfirrmann, Christian W. A.
    Buck, Florian M.
    SKELETAL RADIOLOGY, 2019, 48 (05) : 707 - 712
  • [28] GEOMScope: Large Field-of-View 3D Lensless Microscopy with Low Computational Complexity
    Tian, Feng
    Hu, Junjie
    Yang, Weijian
    LASER & PHOTONICS REVIEWS, 2021, 15 (08)
  • [29] Feasibility study for a low-cost 3D gamma-ray camera
    Tickner, JR
    Currie, M
    Roach, GJ
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (01) : 67 - 71
  • [30] COMPRESSION OF 3D MRI IMAGES BASED ON SYMMETRY IN PREDICTION-ERROR FIELD
    Amraee, S.
    Karimi, N.
    Samavi, S.
    Shirani, S.
    2011 IEEE INTERNATIONAL CONFERENCE ON MULTIMEDIA AND EXPO (ICME), 2011,