Iodine quantification and detectability thresholds among major dual-energy CT platforms

被引:8
|
作者
Taylor, Ross Edward [1 ]
Mager, Pamela [1 ]
Yu, Nam C. [1 ]
Katz, David P. [1 ]
Brady, Jett R. [1 ]
Gupta, Nakul [1 ]
机构
[1] Houston Methodist Hosp, Dept Radiol, Houston, TX 77030 USA
来源
BRITISH JOURNAL OF RADIOLOGY | 2019年 / 92卷 / 1104期
关键词
COMPUTED TOMOGRAPHIC APPARATUS; TO-NOISE RATIO; ADRENAL NODULES; MULTIDETECTOR CT; RENAL MASSES; ACCURACY; AORTOGRAPHY; PERFORMANCE; PRINCIPLES; BIOMARKERS;
D O I
10.1259/bjr.20190530
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To estimate the minimum detectable iodine concentration on multiple dual-energy CT (DECT) platforms. Methods and materials: A phantom containing iodine concentrations ranging from 0 to 10 mg ml(-1) was scanned with five dual-energy platforms (two rapid kilo volt switching (r-kVs), one dual source (DS), one sequential acquisition and one split-filter). Serial dilutions of 300mg ml( -1) iodinated contrast material were used to generate concentrations below 2 mg ml(-1). Iodine density and virtual monoenergetic images were reviewed by three radiologists to determine the minimum visually detectable iodine concentration. Contrast-to-noise ratios (CNRs) were calculated. Results: 1 mg mL(-1) (-0.8 mg mL(-1) corrected) was the minimum visually detectable concentration among the platforms and could be seen by all readers on the third-generation r-kVs and DS platforms. Conclusions: At low concentrations, CNR for monoenergetic images was highest on the DS platform and lowest in the sequential acquisition and split-filter platforms. Advances in knowledge: The results of this study corroborate previous in vivo estimates of iodine detection limits at DECT and provide a comparison for the performance of different DECT platforms at low iodine concentrations in vitro.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Dual-energy CT for liver iron quantification in patients with haematological disorders
    Werner, Sebastian
    Krauss, Bernhard
    Haberland, Ulrike
    Bongers, Malte
    Starke, Uwe
    Bakchoul, Tamam
    Enkel, Sigrid
    Nikolaou, Konstantin
    Horger, Marius
    EUROPEAN RADIOLOGY, 2019, 29 (06) : 2868 - 2877
  • [42] Interdependencies of acquisition, detection, and reconstruction techniques on the accuracy of iodine quantification in varying patient sizes employing dual-energy CT
    Daniele Marin
    Jose J. Pratts-Emanuelli
    Achille Mileto
    Daniela B. Husarik
    Mustafa R. Bashir
    Rendon C. Nelson
    Daniel T. Boll
    European Radiology, 2015, 25 : 679 - 686
  • [43] Quantification of liver iron content with CT—added value of dual-energy
    Michael A. Fischer
    Caecilia S. Reiner
    Dimitri Raptis
    Olivio Donati
    Robert Goetti
    Pierre-Alain Clavien
    Hatem Alkadhi
    European Radiology, 2011, 21 : 1727 - 1732
  • [44] Dual-energy CT for liver iron quantification in patients with haematological disorders
    Sebastian Werner
    Bernhard Krauss
    Ulrike Haberland
    Malte Bongers
    Uwe Starke
    Tamam Bakchoul
    Sigrid Enkel
    Konstantin Nikolaou
    Marius Horger
    European Radiology, 2019, 29 : 2868 - 2877
  • [45] Iodine Images in Dual-energy CT: Detection of Hepatic Steatosis by Quantitative Iodine Concentration Values
    Beck, Stefanie
    Jahn, Laurenz
    Deniffel, Dominik
    Riederer, Isabelle
    Sauter, Andreas
    Makowski, Marcus R.
    Pfeiffer, Daniela
    JOURNAL OF DIGITAL IMAGING, 2022, 35 (06) : 1738 - 1747
  • [46] Interdependencies of acquisition, detection, and reconstruction techniques on the accuracy of iodine quantification in varying patient sizes employing dual-energy CT
    Marin, Daniele
    Pratts-Emanuelli, Jose J.
    Mileto, Achille
    Husarik, Daniela B.
    Bashir, Mustafa R.
    Nelson, Rendon C.
    Boll, Daniel T.
    EUROPEAN RADIOLOGY, 2015, 25 (03) : 679 - 686
  • [47] Dual-energy CT with iodine quantification in distinguishing between bland and neoplastic portal vein thrombosis in patients with hepatocellular carcinoma
    Ascenti, G.
    Sofia, C.
    Mazziotti, S.
    Silipigni, S.
    D'Angelo, T.
    Pergolizzi, S.
    Scribano, E.
    CLINICAL RADIOLOGY, 2016, 71 (09) : 938.e1 - 938.e9
  • [48] Dual-energy CT-based iodine quantification to differentiate abdominal malignant lymphoma from lymph node metastasis
    Martin, Simon S.
    Czwikla, Rouben
    Wichmann, Julian L.
    Albrecht, Moritz H.
    Lenga, Lukas
    Savage, Rock H.
    Arendt, Christophe
    Hammerstingl, Renate
    Vogl, Thomas J.
    Kaltenbach, Benjamin
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 255 - 260
  • [49] Iodine Images in Dual-energy CT: Detection of Hepatic Steatosis by Quantitative Iodine Concentration Values
    Stefanie Beck
    Laurenz Jahn
    Dominik Deniffel
    Isabelle Riederer
    Andreas Sauter
    Marcus R. Makowski
    Daniela Pfeiffer
    Journal of Digital Imaging, 2022, 35 : 1738 - 1747
  • [50] Performance of dual-energy CT with iodine quantification in differentiating for benign versus malignant lymph nodes in patients with lung adenocarcinoma
    Arachchige, Arosh S. Perera Molligoda
    JAPANESE JOURNAL OF RADIOLOGY, 2024, 42 (07) : 798 - 798