Optical Coherence Tomography Assessment of In Vivo Vascular Response After Implantation of Overlapping Bare-Metal and Drug-Eluting Stents

被引:143
|
作者
Guagliumi, Giulio [1 ]
Musumeci, Giuseppe [1 ]
Sirbu, Vasile [1 ]
Bezerra, Hiram G. [2 ]
Suzuki, Nobuaki [2 ]
Fiocca, Luigi [1 ]
Matiashvili, Aleksandre [1 ]
Lortkipanidze, Nikoloz [1 ]
Trivisonno, Antonio [1 ]
Valsecchi, Orazio [1 ]
Biondi-Zoccai, Giuseppe [3 ]
Costa, Marco A. [2 ]
机构
[1] Osped Riuniti Bergamo, Div Cardiol, Cardiovasc Dept, I-24121 Bergamo, Italy
[2] Case Western Reserve Univ, Univ Hosp Case Med Ctr, Harrington McLaughlin Heart & Vasc Inst, Cleveland, OH 44106 USA
[3] Univ Turin, Div Cardiol, Turin, Italy
关键词
coronary artery disease; optical coherence tomography; percutaneous transluminal coronary angioplasty; stent; INTRAVASCULAR ULTRASOUND; THROMBOSIS; COVERAGE;
D O I
10.1016/j.jcin.2010.02.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We designed a randomized trial exploiting optical coherence tomography (OCT) to assess coverage and apposition of overlapping bare-metal stents (BMS) and drug-eluting stents (DES) in human coronary arteries. Background Overlapping DES impair healing in animals. Optical coherence tomography allows accurate in vivo assessment of stent strut coverage and apposition. Methods Seventy-seven patients with long coronary stenoses were randomized to overlapping sirolimus-eluting stents (SES), paclitaxel-eluting stents (PES), zotarolimus-eluting stents (ZES), or BMS. The primary goal of the study was to determine the rate of uncovered/malapposed strut; in overlap versus nonoverlap segments, according to stent type, at 6-month follow-up with OCT. Results A total of 53,047 struts were analyzed. The rate of uncovered/malapposed struts was 1.5 +/- 3.4% and 0.6 +/- 2.7% in overlap versus nonoverlap BMS (p = NS), respectively, and 4.3 +/- 11% and 3.6 +/- 8% in overlap versus nonoverlap DES (p = NS), respectively. There were no differences in the rates of uncovered/malapposed struts between overlapping BMS and DES, likely due to law frequency of uncovered/malapposed struts in ZES (0.1 +/- 0.4%), which offset the higher rates observed in SES (6.7 +/- 9.6%) and PES (6.7 +/- 16.5%, p < 0.05). Overlap segments showed greater neointimal volume obstruction versus nonoverlap segments in all DES (p < 0.05 for all DES types). Strut-level neointimal thickness at overlap and nonoverlap segments were lowest in SES (0.16 +/- 0.1 mm and 0.12 +/- 0.1 mm, respectively) compared with PES (0.27 +/- 0.1 mm and 0.20 +/- 0.1 mm, respectively), ZES (0.40 +/- 0.16 mm and 0.33 +/- 0.13 mm, respectively), and BMS (0.55 +/- 0.31 mm and 0.53 +/- 0.25 mm, respectively, p < 0.05). Conclusions As assessed by OCT the impact of DES on vascular healing was similar at overlapping and nonoverlapping sites. However, strut malapposition, coverage pattern, and neointimal hyperplasia differ significantly according to DES type. (Optical Coherence Tomography for Drug Eluting Stent Safety [ODESSA]; NCT00693030) (J Am Coll Cardiol Intv 2010;3:531-9) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:531 / 539
页数:9
相关论文
共 50 条
  • [41] Drug-Eluting versus Bare-Metal Stents in Large Coronary Arteries
    Kaiser, Christoph
    Galatius, Soeren
    Erne, Paul
    Eberli, Franz
    Alber, Hannes
    Rickli, Hans
    Pedrazzini, Giovanni
    Hornig, Burkhard
    Bertel, Osmund
    Bonetti, Piero
    De Servi, Stefano
    Brunner-La Rocca, Hans-Peter
    Ricard, Ingrid
    Pfisterer, Matthias
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (24): : 2310 - 2319
  • [42] Assessment of vascular response after drug-eluting stents implantation in patients with diabetes mellitus: an optical coherence tomography sub-study of the J-DESsERT
    Takashi Kubo
    Takashi Akasaka
    Takashi Tanimoto
    Masamichi Takano
    Yoshitane Seino
    Kenya Nasu
    Tomonori Itoh
    Kyoichi Mizuno
    Hiroyuki Okura
    Toshiro Shinke
    Jun-ichi Kotani
    Shigenori Ito
    Hiroyoshi Yokoi
    Toshiya Muramatsu
    Masato Nakamura
    Shinsuke Nanto
    Heart and Vessels, 2016, 31 : 465 - 473
  • [43] Optical Coherence Tomography Analysis for Restenosis of Everolimus-Eluting Stents In Comparison with Bare-Metal Stents and Paclitaxel-Eluting Stents
    Kuramitsu, Shoichi
    Iwabuchi, Masashi
    Toyota, Fumitoshi
    Haraguchi, Takuya
    Kazuno, Yoshio
    Enomoto, Soichiro
    Mazaki, Toru
    Domei, Takenori
    Hyodo, Makoto
    Shirai, Shinichi
    Takabatake, Yoshitaka
    Yokoi, Hiroyoshi
    Nobuyoshi, Masakiyo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B181 - B181
  • [44] Assessment of vascular response after drug-eluting stents implantation in patients with diabetes mellitus: an optical coherence tomography sub-study of the J-DESsERT
    Kubo, Takashi
    Akasaka, Takashi
    Tanimoto, Takashi
    Takano, Masamichi
    Seino, Yoshitane
    Nasu, Kenya
    Itoh, Tomonori
    Mizuno, Kyoichi
    Okura, Hiroyuki
    Shinke, Toshiro
    Kotani, Jun-ichi
    Ito, Shigenori
    Yokoi, Hiroyoshi
    Muramatsu, Toshiya
    Nakamura, Masato
    Nanto, Shinsuke
    HEART AND VESSELS, 2016, 31 (04) : 465 - 473
  • [45] Outcomes in the Era of Bare-Metal Stents vs the Era of Drug-Eluting Stents Reply
    Malenka, David J.
    Skinner, Jonathan S.
    Lucas, F. Lee
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (01): : 34 - 34
  • [46] Drug-Eluting Stents vs. Bare-Metal Stents for the Treatment of Svg Lesions
    Collet, Carlos
    Costa, Jose De Ribamar
    Sousa, Amanda
    Feres, Fausto
    Moreira, Adriana
    Abizaid, Alexandre
    Maldonado, Galo
    Cano, Manuel
    Costa, Ricardo
    Staico, Rodolfo
    Siqueira, Dimytri
    Sousa, J. Eduardo
    CIRCULATION, 2010, 122 (21)
  • [48] IN VIVO ASSESSMENT OF IN-STENT NEOATHEROSCLEROSIS AFTER DRUG-ELUTING STENT IMPLANTATION: AN OPTICAL COHERENCE TOMOGRAPHY STUDY
    Miwa, Kenji
    Matsubara, Takao
    Yasuda, Toshihiko
    Inoue, Masaru
    Ukawa, Nobuo
    Okada, Hirofumi
    Yakuta, Youhei
    Matsui, Takao
    Kanaya, Honin
    Kawashiri, Masa-aki
    Yamagishi, Masakazu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1798 - E1798
  • [49] Comparison Between Bare-Metal Stents, First-Generation Drug-Eluting Stents, and Bioresorbable Vascular Scaffolds
    Ng, Andrew Kei-Yan
    Ng, Pauline Yeung
    Siu, Chung-Wah
    Jim, Man-Hong
    JOURNAL OF INVASIVE CARDIOLOGY, 2021, 33 (06): : E467 - E473
  • [50] Drug-eluting stents versus bare-metal stents for saphenous vein graft interventions
    Shah, Rahman
    Hesterberg, Kirstin
    JOURNAL OF THORACIC DISEASE, 2019, 11 : S1257 - S1260