Optical Coherence Tomography Assessment of In Vivo Vascular Response After Implantation of Overlapping Bare-Metal and Drug-Eluting Stents

被引:143
|
作者
Guagliumi, Giulio [1 ]
Musumeci, Giuseppe [1 ]
Sirbu, Vasile [1 ]
Bezerra, Hiram G. [2 ]
Suzuki, Nobuaki [2 ]
Fiocca, Luigi [1 ]
Matiashvili, Aleksandre [1 ]
Lortkipanidze, Nikoloz [1 ]
Trivisonno, Antonio [1 ]
Valsecchi, Orazio [1 ]
Biondi-Zoccai, Giuseppe [3 ]
Costa, Marco A. [2 ]
机构
[1] Osped Riuniti Bergamo, Div Cardiol, Cardiovasc Dept, I-24121 Bergamo, Italy
[2] Case Western Reserve Univ, Univ Hosp Case Med Ctr, Harrington McLaughlin Heart & Vasc Inst, Cleveland, OH 44106 USA
[3] Univ Turin, Div Cardiol, Turin, Italy
关键词
coronary artery disease; optical coherence tomography; percutaneous transluminal coronary angioplasty; stent; INTRAVASCULAR ULTRASOUND; THROMBOSIS; COVERAGE;
D O I
10.1016/j.jcin.2010.02.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We designed a randomized trial exploiting optical coherence tomography (OCT) to assess coverage and apposition of overlapping bare-metal stents (BMS) and drug-eluting stents (DES) in human coronary arteries. Background Overlapping DES impair healing in animals. Optical coherence tomography allows accurate in vivo assessment of stent strut coverage and apposition. Methods Seventy-seven patients with long coronary stenoses were randomized to overlapping sirolimus-eluting stents (SES), paclitaxel-eluting stents (PES), zotarolimus-eluting stents (ZES), or BMS. The primary goal of the study was to determine the rate of uncovered/malapposed strut; in overlap versus nonoverlap segments, according to stent type, at 6-month follow-up with OCT. Results A total of 53,047 struts were analyzed. The rate of uncovered/malapposed struts was 1.5 +/- 3.4% and 0.6 +/- 2.7% in overlap versus nonoverlap BMS (p = NS), respectively, and 4.3 +/- 11% and 3.6 +/- 8% in overlap versus nonoverlap DES (p = NS), respectively. There were no differences in the rates of uncovered/malapposed struts between overlapping BMS and DES, likely due to law frequency of uncovered/malapposed struts in ZES (0.1 +/- 0.4%), which offset the higher rates observed in SES (6.7 +/- 9.6%) and PES (6.7 +/- 16.5%, p < 0.05). Overlap segments showed greater neointimal volume obstruction versus nonoverlap segments in all DES (p < 0.05 for all DES types). Strut-level neointimal thickness at overlap and nonoverlap segments were lowest in SES (0.16 +/- 0.1 mm and 0.12 +/- 0.1 mm, respectively) compared with PES (0.27 +/- 0.1 mm and 0.20 +/- 0.1 mm, respectively), ZES (0.40 +/- 0.16 mm and 0.33 +/- 0.13 mm, respectively), and BMS (0.55 +/- 0.31 mm and 0.53 +/- 0.25 mm, respectively, p < 0.05). Conclusions As assessed by OCT the impact of DES on vascular healing was similar at overlapping and nonoverlapping sites. However, strut malapposition, coverage pattern, and neointimal hyperplasia differ significantly according to DES type. (Optical Coherence Tomography for Drug Eluting Stent Safety [ODESSA]; NCT00693030) (J Am Coll Cardiol Intv 2010;3:531-9) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:531 / 539
页数:9
相关论文
共 50 条
  • [21] Drug-Eluting versus Bare-Metal Stents: When and for Whom?
    Beyar, Rafael
    Nikolsky, Eugenia
    JOURNAL OF INVASIVE CARDIOLOGY, 2008, 20 (03): : 105 - 106
  • [22] Stent thrombosis with drug-eluting and bare-metal stents Reply
    Palmerini, Tullio
    Zoccai, Giuseppe Biondi
    Della Riva, Diego
    Stone, Gregg W.
    LANCET, 2012, 380 (9842): : 646 - 647
  • [23] Drug-Eluting Balloons or Stents for Bare-Metal Stent Restenosis
    Wiebe, Jens
    Colleran, Roisin
    Kastrati, Adnan
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (12) : 1256 - 1258
  • [24] Identification of independent risk factors for restenosis following bare-metal stent implantation: Role of bare-metal stents in the era of drug-eluting stents
    Park, Chang-Bum
    Park, Hoon-Ki
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 6 (03) : 840 - 846
  • [25] Drug-Eluting or Bare-Metal Stents for Coronary Artery Disease
    Urban, Philip
    Oldroyd, Keith
    Krackhardt, Florian
    NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (26): : 2603 - +
  • [26] The comparative safety of bare-metal and drug-eluting intracoronary stents
    Lambert, Nathan D.
    Applegate, Robert J.
    EXPERT REVIEW OF MEDICAL DEVICES, 2010, 7 (05) : 611 - 624
  • [27] Drug-eluting stent implantation for the treatment of bare-metal or drug-eluting stent restenosis
    Nezuo, Shintaro
    Okura, Hiroyuki
    Fukuhara, Kenzo
    Kume, Teruyoshi
    Hayashida, Akihiro
    Neishi, Yoji
    Kawamoto, Takahiro
    Yoshida, Kiyoshi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B183 - B183
  • [28] Implantation of Drug-Eluting Stents Compared to Bare Metal Stents After Intracoronary Thrombectomy
    Wu, Roland S.
    Boland, P.
    Higginbotham, L.
    Dasgupta, N.
    Fiscelar, D.
    Sfakianakis, K.
    Frankli-Bond, T.
    Morgan, K.
    Stant, J.
    Esposito, F.
    Piri, G.
    Reilly, M.
    Duru, S.
    Rabbani, L.
    Brar, S.
    Stone, G.
    Leon, M.
    Moses, J. W.
    Dangas, G.
    Mehran, R.
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 171I - 172I
  • [29] Drug-eluting stents versus bare-metal stents for acute coronary syndrome
    Feinberg, Joshua
    Nielsen, Emil Eik
    Greenhalgh, Janette
    Hounsome, Juliet
    Sethi, Naqash J.
    Safi, Sanam
    Gluud, Christian
    Jakobsen, Janus C.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2017, (08):
  • [30] Comparison in survival outcomes between drug-eluting stents and bare-metal stents
    Omerovic, E.
    EUROPEAN HEART JOURNAL, 2012, 33 : 554 - 554