Optical Coherence Tomography Assessment of In Vivo Vascular Response After Implantation of Overlapping Bare-Metal and Drug-Eluting Stents

被引:143
|
作者
Guagliumi, Giulio [1 ]
Musumeci, Giuseppe [1 ]
Sirbu, Vasile [1 ]
Bezerra, Hiram G. [2 ]
Suzuki, Nobuaki [2 ]
Fiocca, Luigi [1 ]
Matiashvili, Aleksandre [1 ]
Lortkipanidze, Nikoloz [1 ]
Trivisonno, Antonio [1 ]
Valsecchi, Orazio [1 ]
Biondi-Zoccai, Giuseppe [3 ]
Costa, Marco A. [2 ]
机构
[1] Osped Riuniti Bergamo, Div Cardiol, Cardiovasc Dept, I-24121 Bergamo, Italy
[2] Case Western Reserve Univ, Univ Hosp Case Med Ctr, Harrington McLaughlin Heart & Vasc Inst, Cleveland, OH 44106 USA
[3] Univ Turin, Div Cardiol, Turin, Italy
关键词
coronary artery disease; optical coherence tomography; percutaneous transluminal coronary angioplasty; stent; INTRAVASCULAR ULTRASOUND; THROMBOSIS; COVERAGE;
D O I
10.1016/j.jcin.2010.02.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We designed a randomized trial exploiting optical coherence tomography (OCT) to assess coverage and apposition of overlapping bare-metal stents (BMS) and drug-eluting stents (DES) in human coronary arteries. Background Overlapping DES impair healing in animals. Optical coherence tomography allows accurate in vivo assessment of stent strut coverage and apposition. Methods Seventy-seven patients with long coronary stenoses were randomized to overlapping sirolimus-eluting stents (SES), paclitaxel-eluting stents (PES), zotarolimus-eluting stents (ZES), or BMS. The primary goal of the study was to determine the rate of uncovered/malapposed strut; in overlap versus nonoverlap segments, according to stent type, at 6-month follow-up with OCT. Results A total of 53,047 struts were analyzed. The rate of uncovered/malapposed struts was 1.5 +/- 3.4% and 0.6 +/- 2.7% in overlap versus nonoverlap BMS (p = NS), respectively, and 4.3 +/- 11% and 3.6 +/- 8% in overlap versus nonoverlap DES (p = NS), respectively. There were no differences in the rates of uncovered/malapposed struts between overlapping BMS and DES, likely due to law frequency of uncovered/malapposed struts in ZES (0.1 +/- 0.4%), which offset the higher rates observed in SES (6.7 +/- 9.6%) and PES (6.7 +/- 16.5%, p < 0.05). Overlap segments showed greater neointimal volume obstruction versus nonoverlap segments in all DES (p < 0.05 for all DES types). Strut-level neointimal thickness at overlap and nonoverlap segments were lowest in SES (0.16 +/- 0.1 mm and 0.12 +/- 0.1 mm, respectively) compared with PES (0.27 +/- 0.1 mm and 0.20 +/- 0.1 mm, respectively), ZES (0.40 +/- 0.16 mm and 0.33 +/- 0.13 mm, respectively), and BMS (0.55 +/- 0.31 mm and 0.53 +/- 0.25 mm, respectively, p < 0.05). Conclusions As assessed by OCT the impact of DES on vascular healing was similar at overlapping and nonoverlapping sites. However, strut malapposition, coverage pattern, and neointimal hyperplasia differ significantly according to DES type. (Optical Coherence Tomography for Drug Eluting Stent Safety [ODESSA]; NCT00693030) (J Am Coll Cardiol Intv 2010;3:531-9) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:531 / 539
页数:9
相关论文
共 50 条
  • [1] Various vascular responses in restenosis lesions of drug-eluting stents: comparison of optical coherence tomography findings with bare-metal stents
    Yamamoto, M.
    Takano, M.
    Kimata, N.
    Inami, T.
    Murakami, D.
    Okamatsu, K.
    Ohba, T.
    Ibuki, C.
    Seino, Y.
    Mizuno, K.
    EUROPEAN HEART JOURNAL, 2010, 31 : 367 - 367
  • [2] Assessment by Optical Coherence Tomography of Stent Struts Across Side Branch - Comparison of Bare-Metal Stents and Drug-Eluting Stents
    Liu, Yong
    Imanishi, Toshio
    Kubo, Takashi
    Tanaka, Atsushi
    Kitabata, Hironori
    Tanimoto, Takashi
    Ino, Yasushi
    Ikejima, Hideyuki
    Tsujioka, Hiroto
    Komukai, Kenichi
    Ishibashi, Kohei
    Kashiwagi, Manabu
    Ozaki, Yuichi
    Hirata, Kumiko
    Mizukoshi, Masato
    Akasaka, Takashi
    CIRCULATION JOURNAL, 2011, 75 (01) : 106 - 112
  • [3] Drug-eluting or bare-metal stents?
    Irene Fernández-Ruiz
    Nature Reviews Cardiology, 2016, 13 (11) : 631 - 631
  • [4] Qualitative and Quantitative Assessment of Stent Restenosis by Optical Coherence Tomography - Comparison Between Drug-Eluting and Bare-Metal Stents
    Nagoshi, Ryoji
    Shinke, Toshiro
    Otake, Hiromasa
    Shite, Junya
    Matsumoto, Daisuke
    Kawamori, Hiroyuki
    Nakagawa, Masayuki
    Kozuki, Amane
    Hariki, Hirotoshi
    Inoue, Takumi
    Ohsue, Tsuyoshi
    Taniguchi, Yu
    Iwasaki, Masamichi
    Nishio, Ryo
    Hiranuma, Noritoshi
    Konishi, Akihide
    Kinutani, Hiroto
    Miyoshi, Naoki
    Takaya, Tomofumi
    Yamada, Shinichiro
    Yasaka, Yoshinori
    Hayashi, Takatoshi
    Yokoyama, Mitsuhiro
    Kato, Hiroki
    Kadotani, Makoto
    Ohnishi, Yoshio
    Hirata, Ken-ichi
    CIRCULATION JOURNAL, 2013, 77 (03) : 652 - 660
  • [5] Clinical outcome after coronary angioplasty with overlapping drug-eluting and bare-metal stents
    Kubler, P.
    Reczuch, K.
    Jankowska, E. A.
    Luciuk, D.
    Banasiak, W.
    Ponikowski, P.
    EUROPEAN HEART JOURNAL, 2010, 31 : 998 - 998
  • [6] Drug-eluting stents and bare-metal stents: assessment of professional practices
    Hadri, N.
    Federspiel, I.
    Bertrand, B.
    Schmitt, D.
    Calop, J.
    Foroni, L.
    Allenet, B.
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACY, 2012, 34 (01) : 158 - 158
  • [7] Outcome of overlapping heterogenous drug-eluting stents and of overlapping drug-eluting and bare metal stents
    Burzotta, Francesco
    Siviglia, Massimo
    Altamura, Luca
    Trani, Carlo
    Leone, Antonio Maria
    Romagnoli, Enrico
    Mazzari, Mario Attilio
    Mongiardo, Rocco
    Niccoli, Giampaolo
    Brancati, Marta
    Biondi-Zoccai, Giuseppe
    Rebuzzi, Antonio Giuseppe
    Schiavoni, Giovanni
    Crea, Filippo
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (03): : 364 - 368
  • [8] Outcomes of stenting with overlapping drug-eluting stents versus overlapping drug-eluting and bare-metal stents for the treatment of diffuse coronary lesions
    Kassaian, S. E.
    Salarifar, M.
    Dehkordi, M. Raissi
    Alidoosti, M.
    Nematipour, E.
    Poorhosseini, H. R.
    Hajizeinali, A. M.
    Kazemisaleh, D.
    Sharafi, A.
    Mahmoodian, M.
    Paydari, N.
    Farahani, A. V.
    CARDIOVASCULAR JOURNAL OF AFRICA, 2010, 21 (06) : 311 - 315
  • [9] Are drug-eluting stents safer than bare-metal stents?
    Jensen, Lisette Okkels
    Christiansen, Evald Hoj
    LANCET, 2019, 393 (10190): : 2472 - 2474
  • [10] Bare-metal versus drug-eluting coronary stents
    Austin, David
    Pell, Jill P.
    Oldroyd, Keith G.
    NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (23): : 2516 - 2516