Structural feasibility of incorporating the LVEM-isolated floor in the first story of a two-story steel frame

被引:10
|
作者
Xiang, Yang [1 ]
Koetaka, Yuji [2 ]
机构
[1] Kyoto Univ, Grad Sch Engn, Kyoto, Japan
[2] Kyoto Univ, Dept Architecture & Architectural Engn, Kyoto, Japan
关键词
Floor-isolation; Steel frame; Laminated visco-elastic material; Visco-elastic damper; Tuned-mass-damper; Inter-story drift; Floor acceleration; TUNED MASS DAMPER; RESPONSE SPECTRA; DESIGN; MODEL; SENSITIVITY; PERFORMANCE; PARAMETERS;
D O I
10.1016/j.engstruct.2019.109686
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
We introduce a novel floor-isolation system for mitigating the seismic responses of steel frames. In the system, the floors are connected to steel beams by the laminated visco-elastic material (LVEM). In this paper, we present the feasibility of installing the LVEM-isolated floors in the first story of a two-story steel moment-resisting frame. Firstly, we notice that the floor-isolation decouples the composite behavior between the floors and the beams, thus weakens the stiffness of the beams. Based on a generalized frame model, it is demonstrated that such a reduction in beam stiffness only yields a tiny decrease in the global lateral stiffness of the frame. Subsequently, the dynamic analysis model is established for the frame equipped with the LVEM-isolated floor. The LVEM isolators are simulated by a refined Kelvin-Voigt model, while the entire structure is modeled by a three-degree-of-freedom system. The accuracy of the numerical approach is validated by shaking table tests. Based on the established model, a large-scale numerical computation is conducted using 136 earthquake records. The results demonstrate that the structural displacement responses could be remarkably mitigated by the floor-isolation. In general, the reduction of the peak inter-story drift gets more pronounced when a larger mass-isolation ratio and a softer LVEM isolator are applied. For a regular structural design configuration (e.g., mass-isolation ration nu = 0.7, LVEM isolator stiffness ratio kappa = 0.2), a 40% reduction in the peak inter-story drifts could be obtained via the floor-isolation. The ambient temperature notably affects the performance of the floor-isolation system. In many cases, a risen temperature amplifies the benefits of the floor-isolation while a fallen temperature abates such benefits. Meanwhile, the floor-isolation alters the form and the amplitude of the floor acceleration response spectrum (FARS). The peaks of the FARS are significantly mitigated by the LVEM-isolated floors. Quantitatively speaking, we could get a 50% reduction in the peak of FARS from the LVEM-isolated floor system for regular design configurations, say, nu = 0.7, and kappa = 0.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] PSEUDO STATIC TEST ON A SINGLE-SPAN TWO-STORY PRECAST CONCRETE FRAME WITH ENERGY DISSIPATION CLADDING PANELS
    Chong X.
    Huo P.
    Sha H.-L.
    Jiang Q.
    Li H.-R.
    Hou L.-B.
    Feng Y.-L.
    Gongcheng Lixue/Engineering Mechanics, 2024, 41 (01): : 114 - 123
  • [42] PSEUDO-STATIC TESTS OF STIRRUP-CONFINED SQUARE CFST TWO-STORY TWO-SPAN COMPOSITE FRAME STRUCTURE
    Ding F.-X.
    Xu Y.-L.
    Wang L.-P.
    Yin G.-A.
    Yu Z.-W.
    Gongcheng Lixue/Engineering Mechanics, 2023, 40 (04): : 58 - 70
  • [43] Seismic behavior of cold-formed steel framed multi-panel and two-story shear walls
    Pehlivan, Baris Mert
    Baran, Eray
    Topkaya, Cem
    BULLETIN OF EARTHQUAKE ENGINEERING, 2025, : 2201 - 2232
  • [44] Experimental Validation of Wave Vibration Analysis of Complex Vibrations in a Two-Story Metallic Space Frame Based on the Timoshenko Bending Theory
    Mei, C.
    JOURNAL OF VIBRATION AND ACOUSTICS-TRANSACTIONS OF THE ASME, 2016, 138 (02):
  • [45] Seismic Performance of a Full-Scale Two-Story Reinforced Concrete Frame with Shale Sintered Wallboards Tested on a Shake Table
    Xiang, M.
    Zhang, Y. P.
    Zhou, L.
    Tang, L. N.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2024,
  • [46] Planar frame models considering system-level interactions of a two-story low-damage concrete wall building
    Gu, Anqi
    Zhou, Ying
    Lu, Yiqiu
    Yang, Qun
    Henry, Richard S.
    Rodgers, Geoffrey W.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2023, 52 (14): : 4325 - 4351
  • [47] Damage-control design and hybrid tests of a full-scale two-story buckling-restrained braced steel moment frame with sliding gusset connections
    Zhao, Junxian
    Yan, Lijian
    Wang, Chen
    Zhou, Yun
    Chen, Ruobing
    Chan, Tak -Ming
    ENGINEERING STRUCTURES, 2023, 275
  • [49] Experimental study on seismic behavior of two-story shear wall with concrete filled steel tube columns and horizontal joints
    Chen, Jianwei
    Su, Youpo
    Zhang, Chao
    Qi, Hongjia
    Chen, Haibin
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2014, 35 (03): : 93 - 101
  • [50] Full-scale tests of two-story RC frames retrofitted with steel plate multi-slit dampers
    Javidan, Mohammad Mandi
    Nasab, Mohammad Seddiq Eskandari
    Kim, Jinkoo
    STEEL AND COMPOSITE STRUCTURES, 2021, 39 (05): : 645 - 664