Structural feasibility of incorporating the LVEM-isolated floor in the first story of a two-story steel frame

被引:10
|
作者
Xiang, Yang [1 ]
Koetaka, Yuji [2 ]
机构
[1] Kyoto Univ, Grad Sch Engn, Kyoto, Japan
[2] Kyoto Univ, Dept Architecture & Architectural Engn, Kyoto, Japan
关键词
Floor-isolation; Steel frame; Laminated visco-elastic material; Visco-elastic damper; Tuned-mass-damper; Inter-story drift; Floor acceleration; TUNED MASS DAMPER; RESPONSE SPECTRA; DESIGN; MODEL; SENSITIVITY; PERFORMANCE; PARAMETERS;
D O I
10.1016/j.engstruct.2019.109686
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
We introduce a novel floor-isolation system for mitigating the seismic responses of steel frames. In the system, the floors are connected to steel beams by the laminated visco-elastic material (LVEM). In this paper, we present the feasibility of installing the LVEM-isolated floors in the first story of a two-story steel moment-resisting frame. Firstly, we notice that the floor-isolation decouples the composite behavior between the floors and the beams, thus weakens the stiffness of the beams. Based on a generalized frame model, it is demonstrated that such a reduction in beam stiffness only yields a tiny decrease in the global lateral stiffness of the frame. Subsequently, the dynamic analysis model is established for the frame equipped with the LVEM-isolated floor. The LVEM isolators are simulated by a refined Kelvin-Voigt model, while the entire structure is modeled by a three-degree-of-freedom system. The accuracy of the numerical approach is validated by shaking table tests. Based on the established model, a large-scale numerical computation is conducted using 136 earthquake records. The results demonstrate that the structural displacement responses could be remarkably mitigated by the floor-isolation. In general, the reduction of the peak inter-story drift gets more pronounced when a larger mass-isolation ratio and a softer LVEM isolator are applied. For a regular structural design configuration (e.g., mass-isolation ration nu = 0.7, LVEM isolator stiffness ratio kappa = 0.2), a 40% reduction in the peak inter-story drifts could be obtained via the floor-isolation. The ambient temperature notably affects the performance of the floor-isolation system. In many cases, a risen temperature amplifies the benefits of the floor-isolation while a fallen temperature abates such benefits. Meanwhile, the floor-isolation alters the form and the amplitude of the floor acceleration response spectrum (FARS). The peaks of the FARS are significantly mitigated by the LVEM-isolated floors. Quantitatively speaking, we could get a 50% reduction in the peak of FARS from the LVEM-isolated floor system for regular design configurations, say, nu = 0.7, and kappa = 0.
引用
收藏
页数:18
相关论文
共 50 条
  • [22] Sub-structural pseudo-dynamic performance of two full-scale two-story steel plate shear walls
    Lin, Chih-Han
    Tsai, Keh-Chyuan
    Qu, Bing
    Bruneau, Michel
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (12) : 1467 - 1482
  • [23] Seismic responses of a free-standing two-story steel moment frame equipped with a cast iron-mortar sliding base
    Chung, Yu-Lin
    Kuo, Kuan-Ting
    Nagae, Takuya
    Kajiwara, Koichi
    EARTHQUAKES AND STRUCTURES, 2019, 17 (03) : 245 - 256
  • [24] Shake table test of a two-story steel building seismically retrofitted using gravity-controlled rocking braced frame system
    Mottier, Paul
    Tremblay, Robert
    Rogers, Colin
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2021, 50 (06): : 1576 - 1594
  • [25] Evaluation of Vibration Detection Using Smartphones in a Two-Story Masonry-Infilled RC Frame Building
    Kang, Jae-Do
    Baek, Eun-Rim
    Park, Sung-Ho
    BUILDINGS, 2023, 13 (04)
  • [26] Cyclic performance of full-scale two-story narrow steel plate shear walls
    Li, Chao-Hsien
    Tsai, Keh-Chyuan
    Lin, Chih-Han
    STESSA 2009 - BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2009, : 153 - +
  • [27] Cyclic Loading Test for Two-Story RC Moment Frames Retrofitted with Internal Steel Frames
    Lee, Ho-Jun
    Lee, Hae-Bin
    Park, Hong-Gun
    Lee, Jong-Kweon
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (02)
  • [28] Effect of boundary condition on the cyclic response of I-shaped steel columns: Two-story subassemblage versus isolated column tests
    Chou, Chung-Che
    Lai, Yun-Chuan
    Xiong, Hou-Chun
    Lin, Te-Hung
    Uang, Chia-Ming
    Mosqueda, Gilberto
    Ozkula, Gulen
    El-Tawil, Sherif
    McCormick, Jason P.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2022, 51 (14): : 3434 - 3455
  • [29] Improving the structural robustness of multi-story steel-frame buildings
    Dinu, Florea
    Dubina, Dan
    Marginean, Ioan
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2015, 11 (08) : 1028 - 1041
  • [30] Collapsing process simulations of timber structures under dynamic loading I: simulations of two-story frame models
    Nakagawa, T
    Ohta, M
    JOURNAL OF WOOD SCIENCE, 2003, 49 (05) : 392 - 397