Structural feasibility of incorporating the LVEM-isolated floor in the first story of a two-story steel frame

被引:10
|
作者
Xiang, Yang [1 ]
Koetaka, Yuji [2 ]
机构
[1] Kyoto Univ, Grad Sch Engn, Kyoto, Japan
[2] Kyoto Univ, Dept Architecture & Architectural Engn, Kyoto, Japan
关键词
Floor-isolation; Steel frame; Laminated visco-elastic material; Visco-elastic damper; Tuned-mass-damper; Inter-story drift; Floor acceleration; TUNED MASS DAMPER; RESPONSE SPECTRA; DESIGN; MODEL; SENSITIVITY; PERFORMANCE; PARAMETERS;
D O I
10.1016/j.engstruct.2019.109686
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
We introduce a novel floor-isolation system for mitigating the seismic responses of steel frames. In the system, the floors are connected to steel beams by the laminated visco-elastic material (LVEM). In this paper, we present the feasibility of installing the LVEM-isolated floors in the first story of a two-story steel moment-resisting frame. Firstly, we notice that the floor-isolation decouples the composite behavior between the floors and the beams, thus weakens the stiffness of the beams. Based on a generalized frame model, it is demonstrated that such a reduction in beam stiffness only yields a tiny decrease in the global lateral stiffness of the frame. Subsequently, the dynamic analysis model is established for the frame equipped with the LVEM-isolated floor. The LVEM isolators are simulated by a refined Kelvin-Voigt model, while the entire structure is modeled by a three-degree-of-freedom system. The accuracy of the numerical approach is validated by shaking table tests. Based on the established model, a large-scale numerical computation is conducted using 136 earthquake records. The results demonstrate that the structural displacement responses could be remarkably mitigated by the floor-isolation. In general, the reduction of the peak inter-story drift gets more pronounced when a larger mass-isolation ratio and a softer LVEM isolator are applied. For a regular structural design configuration (e.g., mass-isolation ration nu = 0.7, LVEM isolator stiffness ratio kappa = 0.2), a 40% reduction in the peak inter-story drifts could be obtained via the floor-isolation. The ambient temperature notably affects the performance of the floor-isolation system. In many cases, a risen temperature amplifies the benefits of the floor-isolation while a fallen temperature abates such benefits. Meanwhile, the floor-isolation alters the form and the amplitude of the floor acceleration response spectrum (FARS). The peaks of the FARS are significantly mitigated by the LVEM-isolated floors. Quantitatively speaking, we could get a 50% reduction in the peak of FARS from the LVEM-isolated floor system for regular design configurations, say, nu = 0.7, and kappa = 0.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Single-story steel structure with LVEM-isolated floor: Elastic seismic performance and design response spectrum
    Xiang, Yang
    Koetaka, Yuji
    Okuda, Naoki
    ENGINEERING STRUCTURES, 2019, 196
  • [2] Shaking table tests of a two-story unbraced steel frame
    Kim, Seung-Eock
    Lee, Dong-Ho
    Ngo-Huu, Cuong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (03) : 412 - 421
  • [3] Thermal and structural response of a two-story, two bay composite steel frame under fire loading
    Dong, Yuli
    Prasad, Kuldeep
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2009, 32 : 2543 - 2550
  • [4] Experimental Study on the Progressive Collapse Resistance of a Two-Story Steel Moment Frame
    Chen, Junling
    Huang, Xin
    Ma, Renle
    He, Minjuan
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2012, 26 (05) : 567 - 575
  • [5] Damage diagnosis to a two-story steel braced-frame model structure
    Ji, X. D.
    Qian, J. R.
    STRUCTURAL HEALTH MONITORING AND INTELLIGENT INFRASTRUCTURE, VOLS 1 AND 2, 2006, : 799 - 805
  • [6] Experimental Study on Aseismatic Property of A Two-bay Two-story Lightweight Steel Frame
    Xu, Feng
    Jia, Lianguang
    Liu, Ming
    Pan, Jing
    ADVANCES IN ENERGY SCIENCE AND TECHNOLOGY, PTS 1-4, 2013, 291-294 : 1001 - +
  • [7] Structural behavior of a single bay two-story basalt fibre reinforced concrete frame
    Moorthy, Gnanasundar Valarmathi
    Thangaraj, Palanisamy
    Shanmugam, Thirugnanam Gobi
    GRADEVINAR, 2022, 74 (12): : 1085 - 1092
  • [8] Response spectra of two-story frames with racks on the elastic floor
    Zhang, Wei-Guang
    Tong, Gen-Shu
    JOURNAL OF BUILDING ENGINEERING, 2021, 43
  • [9] Lateral cyclic performance of a CFRP retrofitted two-story RC frame with open ground story
    Birendra K. Karaiya
    Romanbabu M. Oinam
    Dipti Ranjan Sahoo
    Ashok Gupta
    Bulletin of Earthquake Engineering, 2020, 18 : 5919 - 5939
  • [10] Lateral cyclic performance of a CFRP retrofitted two-story RC frame with open ground story
    Karaiya, Birendra K.
    Oinam, Romanbabu M.
    Sahoo, Dipti Ranjan
    Gupta, Ashok
    BULLETIN OF EARTHQUAKE ENGINEERING, 2020, 18 (13) : 5919 - 5939