Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia

被引:18
|
作者
Maria Vasquez, Ana [1 ]
Zuluaga, Lina [1 ]
Tobon, Alberto [1 ]
Posada, Maritza [1 ]
Velez, Gabriel [1 ]
Gonzalez, Iveth J. [2 ]
Campillo, Ana [2 ]
Ding, Xavier [2 ]
机构
[1] Univ Antioquia, Fac Med, Grp Malaria, Carrera 53 61-30,Lab 610, Medellin, Colombia
[2] FIND, Geneva, Switzerland
关键词
Malaria in pregnancy; Diagnostics; Rapid diagnostic test; Light microscopy; Loop mediated isothermal amplification; Polymerase chain reaction; POLYMERASE-CHAIN-REACTION; PLASMODIUM-VIVAX INFECTIONS; ASYMPTOMATIC MALARIA; MICROSCOPY; FALCIPARUM; BURDEN; KIT;
D O I
10.1186/s12936-018-2403-5
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Pregnant women frequently show low-density Plasmodium infections that require more sensitive methods for accurate diagnosis and early treatment of malaria. This is particularly relevant in low-malaria transmission areas, where intermittent preventive treatment is not recommended. Molecular methods, such as polymerase chain reaction (PCR) are highly sensitive, but require sophisticated equipment and advanced training. Instead, loop mediated isothermal amplification (LAMP) provides an opportunity for molecular detection of malaria infections in remote endemic areas, outside a reference laboratory. The aim of the study is to evaluate the performance of LAMP for the screening of malaria in pregnant women in Colombia. Methods: This is a nested prospective study that uses data and samples from a larger cross-sectional project conducted from May 2016 to January 2017 in three Colombian endemic areas (El Bagre, Quibdo, and Tumaco). A total of 531 peripheral and placental samples from pregnant women self-presenting at local hospitals for antenatal care visits, at delivery or seeking medical care for suspected malaria were collected. Samples were analysed for Plasmodium parasites by light microscopy (LM), rapid diagnostic test (RDT) and LAMP. Diagnostic accuracy endpoints (sensitivity, specificity, predictive values, and kappa scores) of LM, RDT and LAMP were compared with nested PCR (nPCR) as the reference standard. Results: In peripheral samples, LAMP showed an improved sensitivity (100.0%) when compared with LM 79.5% and RDT 76.9% (p <0.01), particularly in afebrile women, for which LAMP sensitivity was two-times higher than LM and RDT. Overall agreement among LAMP and nPCR was high (kappa value= 1.0). Specificity was similar in all tests (100%). In placental blood, LAMP evidenced a four-fold improvement in sensitivity (88.9%) when compared with LM and RDT (22.2%), being the only method, together with nPCR, able to detect placental infections in peripheral blood. Conclusions: LAMP is a simple, rapid and accurate molecular tool for detecting gestational and placental malaria, being able to overcome the limited sensitivity of LM and RDT. These findings could guide maternal health programs in low-transmission settings to integrate LAMP in their surveillance systems for the active detection of low-density infections and asymptomatic malaria cases.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Establishment of loop-mediated isothermal amplification (LAMP) for rapid detection of Brucella spp. and application to milk and blood samples
    Song, Liuyan
    Li, Juntao
    Hou, Shuiping
    Li, Xunde
    Chen, Shouyi
    JOURNAL OF MICROBIOLOGICAL METHODS, 2012, 90 (03) : 292 - 297
  • [32] Direct detection of Aeromonas hydrophila from water and tissue samples by loop-mediated isothermal amplification (LAMP) method
    Gahlawat, S. K.
    Saharan, P.
    Duhan, J. S.
    RESEARCH JOURNAL OF BIOTECHNOLOGY, 2024, 19 (08): : 46 - 52
  • [33] Diagnostic performance of loop-mediated isothermal amplification (LAMP) and Ultra-sensitive PCR in diagnosis of malaria in western Saudi Arabia
    Solimam, Rasha H.
    Martin-Ramirez, Alexandra
    Rubio, Jose M.
    Khalifa, Eman A.
    Hussein, Bushra E.
    Wahab, Maha M.
    Lanza, Marta
    Hawash, Yousry A.
    ACTA PROTOZOOLOGICA, 2023, 62 : 15 - 23
  • [34] Performance of a highly sensitive rapid diagnostic test (HS-RDT) for detecting malaria in peripheral and placental blood samples from pregnant women in Colombia
    Maria Vasquez, Ana
    Catalina Medina, Ana
    Tobon-Castano, Alberto
    Posada, Maritza
    Jaime Velez, Gabriel
    Campillo, Ana
    Gonzalez, Iveth J.
    Ding, Xavier
    PLOS ONE, 2018, 13 (08):
  • [35] Added value of loop-mediated isothermal amplification technology (LAMP) in real life for the diagnosis of malaria in travellers
    Burdino, Elisa
    Calleri, Guido
    Ghisetti, Valeria
    JOURNAL OF TRAVEL MEDICINE, 2019, 26 (07)
  • [36] A Loop-Mediated Isothermal Amplification (LAMP) Assay for Early Detection of Schistosoma mansoni in Stool Samples: A Diagnostic Approach in a Murine Model
    Fernandez-Soto, Pedro
    Gandasegui Arahuetes, Javier
    Sanchez Hernandez, Alicia
    Lopez Aban, Julio
    Vicente Santiago, Belen
    Muro, Antonio
    PLOS NEGLECTED TROPICAL DISEASES, 2014, 8 (09):
  • [37] DIAGNOSTIC PERFORMANCE OF A NOVEL MALARIA LOOP MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) ASSAY IN A FIELD SETTING
    Oriero, Eniyou C.
    Okebe, Joseph
    Njie, Sarjo
    Jacobs, Jan
    Van Geertruyden, Jean-Pierre
    Nwakanma, Davis
    D'Alessandro, Umberto
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2015, 93 (04): : 69 - 69
  • [38] A loop-mediated isothermal amplification (LAMP) assay for detection ofToxoplasma gondiiinfection in women with spontaneous abortion
    Kheirandish, Farnaz
    Fallahi, Shirzad
    Mahmoudvand, Hossein
    Araban, Ali
    Anbari, Khatereh
    Rouzbahani, Arian Karimi
    Akbari, Soheila
    ARCHIVES OF MICROBIOLOGY, 2021, 203 (02) : 763 - 769
  • [39] Loop Mediated Isothermal Amplification (LAMP) Accurately Detects Malaria DNA from Filter Paper Blood Samples of Low Density Parasitaemias
    Aydin-Schmidt, Berit
    Xu, Weiping
    Gonzalez, Iveth J.
    Polley, Spencer D.
    Bell, David
    Shakely, Deler
    Msellem, Mwinyi I.
    Bjorkman, Anders
    Martensson, Andreas
    PLOS ONE, 2014, 9 (08):
  • [40] Diagnostic accuracy of loop-mediated isothermal amplification hi detection of Clostridium difficile in stool samples: a meta-analysis
    Chen Wei
    Liu Wen-En
    Li Yang-Ming
    Luo Shan
    Zhong Yi-Ming
    ARCHIVES OF MEDICAL SCIENCE, 2015, 11 (05) : 927 - 936