Diagnostic performance of loop-mediated isothermal amplification (LAMP) and Ultra-sensitive PCR in diagnosis of malaria in western Saudi Arabia

被引:0
|
作者
Solimam, Rasha H. [1 ]
Martin-Ramirez, Alexandra [2 ]
Rubio, Jose M. [2 ,3 ]
Khalifa, Eman A. [1 ]
Hussein, Bushra E. [4 ]
Wahab, Maha M. [5 ]
Lanza, Marta [2 ]
Hawash, Yousry A. [1 ]
机构
[1] Taif Univ, Dept Microbiol, Coll Med, Taif, Saudi Arabia
[2] Inst Salud Carlos III, Natl Microbiol Ctr, Malaria & Emerging Parasit Dis Lab, Madrid, Spain
[3] CIBERINFEC, Ctr Invest Biomed Red Enfermedades Infecc, Madrid, Spain
[4] Univ Tanta, Dept Trop Med & Infect Dis, Fac Med, Tanta, Egypt
[5] KFMC Taif, Dept Microbiol & Parasitol, Taif, Saudi Arabia
关键词
malaria; LAMP; ultrasensitive PCR; diagnosis; METAANALYSIS;
D O I
10.4467/16890027AP.23.002.17903
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Malaria diagnosis continues to be one of the most important steps in the cycle of control specially in endemic countries with low parasitic load infections. Loop-mediated isothermal amplification (LAMP) and ultrasensitive PCR (Us-PCR) are two promising candidates for malaria diagnosis. A cross sectional study performed at King Faisal Hospital, Taif KSA involved patients suffering from signs and symptoms suggesting of malaria, 35 blood samples diagnosed by Nested Multiplex PCR as a reference method (13 P. falciparum, 17 P. vivax, 3 mixed P. falciparum and P. vivax) plus two negative controls were selected to be included in this study to analyse the performance of two LAMP methods (LAMP OptiGene (R) and LAMP WarmStart (R)) and two ultrasensitive PCRs (Us-PCR TARE-2 and Us-PCR Var-ATS). LAMP OptiGene (R) and LAMP WarmStart (R) performances were identical and better than the performance of Us PCR TARE 2 and Us-PCR var-ATS for P. falciparum, achieving 93.75% sensitivity, 100% specificity and 97.17% accuracy versus 87.5% sensitivity, 100% specificity and 94.29% accuracy for the Us PCR TARE 2 and 81.25% sensitivity, 94.74% specificity and 88.57% accuracy for the Us PCR var-ATS respectively. In P. vivax diagnosis LAMP OptiGene (R) performed excellently with 100% sensitivity, specificity, and accuracy while LAMP WarmStart (R) and Us-PCR Cox1 achieved 100% sensitivity, specificity 93.33% and 97.14% accuracy. The study results highlighted the benefits of using LAMP techniques for field diagnosis of malaria in different settings where the need for a more sensitive and reliable molecular tool is mandatory but at the same time removing the high cost, long turnaround time and the need of highly specialized trained technicians to perform more sophisticated molecular techniques.
引用
收藏
页码:15 / 23
页数:9
相关论文
共 50 条
  • [1] MALARIA DIAGNOSIS BY LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) IN THAILAND
    Ocker, Ronja
    Prompunjai, Yongyut
    Chutipongvivate, Salakchit
    Karanis, Panagiotis
    REVISTA DO INSTITUTO DE MEDICINA TROPICAL DE SAO PAULO, 2016, 58
  • [2] Loop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malaria
    Paris, D.
    Imwong, M.
    Faiz, M.
    Hasan, M.
    Bin Yunus, E.
    Silamut, K.
    Lee, S.
    Day, N.
    Dondorp, A.
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2007, 12 : 129 - 129
  • [3] Loop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malaria
    Paris, Daniel H.
    Imwong, Mallika
    Faiz, Abul M.
    Hasan, Mahtabuddin
    Bin Yunus, Entran
    Silamut, Kamolrat
    Lee, Sue J.
    Day, Nicholas P. J.
    Dondorp, Arjen M.
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2007, 77 (05): : 972 - 976
  • [4] Rapid and Sensitive Diagnosis of Cattle Anaplasmosis by Loop-Mediated Isothermal Amplification (LAMP)
    Wen, Xiao-Bo
    Jiang, Hui-Ting
    Zhang, Yang-Long
    Lang, Xiu-Yan
    Liu, Jiao
    Ni, Hong-Bo
    PAKISTAN VETERINARY JOURNAL, 2016, 36 (02) : 174 - 178
  • [5] Poor Diagnostic Performance of a Species-Specific Loop-Mediated Isothermal Amplification (LAMP) Platform for Malaria
    Kollenda, Hans
    Hagen, Ralf Matthias
    Hanke, Miriam
    Rojak, Sandra
    Hinz, Rebecca
    Wassill, Lars
    Poppert, Sven
    Tannich, Egbert
    Frickmann, Hagen
    EUROPEAN JOURNAL OF MICROBIOLOGY AND IMMUNOLOGY, 2018, 8 (04): : 112 - 118
  • [6] Loop-Mediated Isothermal Amplification (LAMP): The Better Sibling of PCR?
    Soroka, Marianna
    Wasowicz, Barbara
    Rymaszewska, Anna
    CELLS, 2021, 10 (08)
  • [7] Performance of rapid diagnostic tests, microscopy, loop-mediated isothermal amplification (LAMP) and PCR for malaria diagnosis in Ethiopia: a systematic review and meta-analysis
    Feleke, Daniel Getacher
    Alemu, Yonas
    Yemanebirhane, Nebiyou
    MALARIA JOURNAL, 2021, 20 (01)
  • [8] Performance of rapid diagnostic tests, microscopy, loop-mediated isothermal amplification (LAMP) and PCR for malaria diagnosis in Ethiopia: a systematic review and meta-analysis
    Daniel Getacher Feleke
    Yonas Alemu
    Nebiyou Yemanebirhane
    Malaria Journal, 20
  • [9] Loop-Mediated Isothermal Amplification for Diagnosis of Zoonotic Malaria
    Lai, Meng Yee
    Sohairi, Ainaa Nadrah
    Zen, Lee Phone Youth
    Abdullah, Mohd Lutfi
    Lau, Yee Ling
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2024, 111 (04): : 765 - 769
  • [10] Performance of loop-mediated isothermal amplification (LAMP) for the diagnosis of malaria among malaria suspected pregnant women in Northwest Ethiopia
    Banchamlak Tegegne
    Sisay Getie
    Wossenseged Lemma
    Abu Naser Mohon
    Dylan R. Pillai
    Malaria Journal, 16