Multicentre validation of IMRT pre-treatment verification: Comparison of in-house and external audit

被引:27
|
作者
Jornet, Nuria [1 ]
Carrasco, Pablo [1 ]
Beltran, Merce [2 ]
Francisco Calvo, Juan [3 ]
Escude, Lluis [4 ]
Hernandez, Victor [5 ]
Quera, Jaume [6 ]
Saez, Jordi [2 ]
机构
[1] Hosp Santa Creu & Sant Pau, Serv Radiofis & Radioproteccio, Barcelona, Spain
[2] Hosp Vall dHebro, Serv Fis, Barcelona, Spain
[3] Hosp Quiron, Serv Oncol Radioterap, Barcelona, Spain
[4] Clin Teknon, Serv Oncol Radioterap, Barcelona, Spain
[5] Hosp St Joan, Serv Fis, Reus, Spain
[6] Hosp Esperanza, Serv Oncol Radioterap, Barcelona, Spain
关键词
IMRT; Audit; Quality assurance; MODULATED RADIATION-THERAPY; RADIOCHROMIC FILM DOSIMETRY; QUALITY-ASSURANCE; EBT2; FILM; RADIOTHERAPY; COMPLEXITY; INDEX; QA;
D O I
10.1016/j.radonc.2014.06.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: We performed a multicentre intercomparison of IMRT optimisation and dose planning and IMRT pre-treatment verification methods and results. The aims were to check consistency between dose plans and to validate whether in-house pre-treatment verification results agreed with those of an external audit. Materials and methods: Participating centres used two mock cases (prostate and head and neck) for the intercomparison and audit. Compliance to dosimetric goals and total number of MU per plan were collected. A simple quality index to compare the different plans was proposed. We compared gamma index pass rates using the centre's equipment and methodology to those of an external audit. Results: While for the prostate case, all centres fulfilled the dosimetric goals and plan quality was homogeneous, that was not the case for the head and neck case. The number of MU did not correlate with the plan quality index. Pre-treatment verifications results of the external audit did not agree with those of the in-house measurements for two centres: being within tolerance for in-house measurements and unacceptable for the audit or the other way round. Conclusions: Although all plans fulfilled dosimetric constraints, plan quality is highly dependent on the planner expertise. External audits are an excellent tool to detect errors in IMRT implementation and cannot be replaced by intercomparison using results obtained by centres. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:381 / 388
页数:8
相关论文
共 50 条
  • [41] The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields
    Van Esch, A
    Depuydt, T
    Huyskens, DP
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 (02) : 223 - 234
  • [42] Clinical experience with the pre-treatment dosimetric verification of IMRT plans using a diode array and independent dose calculator
    Leszczynski, K.
    Wang, X.
    Provost, D.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S204 - S204
  • [43] Clinical validation of an in-house EPID dosimetry system for IMRT QA at the Prince of Wales Hospital
    Tyler, M.
    Vial, P.
    Metcalfe, P.
    Downes, S.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [44] Pre-treatment quality assurance for IMRT treatments of pancreatic cancers
    Beavis, A
    Bubula, E
    Ganney, P
    MEDICAL PHYSICS, 2002, 29 (06) : 1267 - 1267
  • [45] Comparison of author satisfaction between in-house and external editing services
    Lim, J. S.
    Topping, V.
    Kim, S. -H.
    Kim, T. W.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2017, 50 : S145 - S145
  • [46] Radiotherapy pre-treatment dose validation: A second verification of monitor units (MU) with a commercial software
    Al Amri, Iqbal
    Ravichandran, Ramamoorthy
    Sivakumar, Somangili Satyamoorthi
    Binukumar, Johnson Pichi
    Davis, Chirayathmanjiyil Antony
    Al Rahbi, Zakia
    Al Shukeili, Khalsa
    Al Kindi, Fatima
    JOURNAL OF MEDICAL PHYSICS, 2012, 37 (04) : 235 - 239
  • [47] Attracting Applicants for In-House and Outsourced Internal Audit Positions: Views from External Auditors
    Bartlett, Geoffrey D.
    Kremin, Joleen
    Saunders, K. Kelli
    Wood, David A.
    ACCOUNTING HORIZONS, 2016, 30 (01) : 143 - 156
  • [48] Comparison of multi-institutional pre-treatment verification for VMAT of nasopharynx with delivery errors
    Pogson, E. M.
    Arumugam, S.
    Hansen, C. R.
    Currie, M.
    Blake, S. J.
    Roberts, N.
    Carolan, M.
    Vial, P.
    Alharthi, T.
    Holloway, L.
    Thwaites, D. I.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 53 : 25 - 31
  • [49] Pre-treatment VMAT verification with SunCHECK Fraction 0 and Varian Portal Dosimetry - a comparison
    Hoven, N. I.
    Kalsnes, J.
    Lonne, P.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S955 - S956
  • [50] Sensitivity of an Elekta iView GT a-Si EPID model to delivery errors for pre-treatment verification of IMRT fields
    Herwiningsih, Sri
    Hanlon, Peta
    Fielding, Andrew
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (04) : 763 - 770